HomeMy WebLinkAboutNORTHSIDE AZTLAN COMMUNITY CENTER - PDP - 54-05 - CORRESPONDENCE -Number: 66 [4/26/06] Created: 1 /11 /2006 [1/11/06] Add a meter vault on the new 3-inch irrigation service. Number: 86 Created: 4/26/2006 [4/26/06] Plans are okay for preliminary. A more detailed review will be done at final. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 4 Created: 12/28/2005 [4/20/06] [12/28/05] On the overall site plan, note the building envelope, footprint and distance to property lines. Number: 6 Created: 12/28/2005 [4/20/06] [12/28/05] Please remove landscaping items from the site plan. Existing items or items to be removed can be shown on the landscape plan. Number: 10 Created: 12/28/2005 [4/24/06] [12/28/05] 3.2.1(1)(4)Landscape plans: On the legend what do the types A through D reference as far as the types of ground covers and grasses. Should this cross-reference the "Landscape Category"? Number: 82 Created: 4/20/2006 [4/20/06] Would like to see topo lines removed from the overall site plan and site plan sections Be sure and return all of your redlined plans when you re -submit for Final Plan Review! For the hearing, please submit the letters of intent no later than May 9°i, 2006. I will also need 2- complete sets of the site, landscape, arch and I ghting_plans prior to May 10"' for the. hearing. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6206. Sincerely, Anne H. Aspen City Planner Page 5 connects with the original drive aisle off Willow Street. Please see redline returned with comments. [2/16/06] EMERGENCY ACCESS: An approved fire lane is required. It shall be visible by painting and signage, and maintained unobstructed. The fire lane plans shall be submitted prior to installation. Department: Transportation Planning Issue Contact: David Averill Topic: Overall Utility Plan Number: 84 Created: 4/25/2006 [4/25/06] The sidewalk on the north side of the building needs to be configured at 6' minimum since it is adjacent to head -in parking. I think we should perhaps talk about widening it beyond that if indeed there is no curb there (as indicated on sheet 5 of the Utility Plans). Seems to me that it will be easy for vehicles to park on this walking surface if we do not take some sort of action (curb, wheel stops, or something else?) to keep that from happening. Thanks. Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Drainage Plan Number: 17 Created: 1 /5/2006 [4/25/06] Still need details for bio-swales as well as landscaping in drainage channels. Please provide a calculation for 100 year flows within the channel. You may need to stub out pipe to future development on the Willow Street Lofts. Coordinate with Willow Street Lofts design. [1/5/06] Please provide a detail for the proposed bio-swales. , Thank you for including all of the off -site areas in your water quality pond design. At final plan review, water quality outlet details should be provided. At final, more analysis will be required regarding the overtopping of the water quality pond. Reinforcement of the overflow area might be required. Topic: Plat Number: 85 Created: 4/25/2006 [4/25/06] Utility alignment should include swale taking drainage from United Way and Willow Street project. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterlWW Number: 60 Created: 1 /11 /2006 [4/26/06] [1/11/06] Provide easement for the water main, fire hydrant and curb stop. Number: 61 Created: 1/11/2006 [4/26/06] [1/11/06] Add notes on the abandonment of water/sewer lines and services. Number: 65 Created: 1 /11 /2006 [4/26/06] [1/11/061 Have existing 3-inch irrigation line located and shown on the plans. Page 4 requirement along Willow Street will be required. Further work into arriving at the amount will need to be made. Number: 90 Created: 4/26/2006 [4/26/06] It should be noted that the sidewalk along Willow Street may possibly change with future Willow Street improvements. Topic: Plat Number: 87 Created: 4/26/2006 [4/26/06] Tracts A & B on sheet 2 of the plat have a note referring to Sheet 1. 1 don't seem to see any information on Sheet 1 pertinent to these references. Department: Light & Power Issue Contact: Doug Martine Topic: Electric Utility Number: 1 Created: 12/23/2005 [4/13/06] [12/23/05] In order to maintain electric service to the existing facility during construction, substantial temporary relocations of the electric utility system will be necessary at owner's expense. Number: 2 Created: 12/23/2005 [4/13/06] [12/23/05] Light & Power will need electric load information provided by completing a C-1 form. Also will need to have the locations of new electric lines and transformer coordinated with Light & Power. The transformer will need to be within 10 ft. of an all weather service accessible to a utility line truck. Other minimum clearance requirements will apply. Department: Natural Resources Issue Contact: Doug Moore Topic: Landscape Plan Number: 47 Created: 1 /10/2006 [4/14/06] In addition to the previous comment the bio-swale plantings will also need to provide additional details and planting schedule. [1/10/06] Landscape Plan lacks detail at this level of review. The next submittal should include planting notes and schedules listing ratios native seed mixes. Number: 83 Created: 4/24/2006 [4/24/06] Final Compliance plans will need more detail such as planting schedules for seed mixes (including species, quantity, ratio, etc.). Department: PFA Issue Contact: Carle Dann Topic: fire Number: 75 Created: 2/16/2006 [4/26/06] The Fire Department Connection to supply the sprinkler system must be adjacent to the fire lane, for accessibility. [2/16/06] AUTOMATIC SPRINKLERS: The proposed building shall be fire sprinklered. Number: 76 Created: 2/16/2006 [4/26/06] The Emergency Access Easement shown on the plat is insufficient and incorrect. Here is what must be dedicated on the plat: From Willow Street, the drive aisle all the way north to the first drive aisle north of the structure, then west to the end of that drive aisle, north to the next closest drive aisle, then east to the original drive aisle, and south until it Page 3 Number: 93 Created: 5/1/2006 [5/1/06] Final Plan Review: Clark and I are a little confused about the revisions made to the front "orchard". What kind of trees are they? Hopefully not Aspen. It might be really nice with Serviceberry (tree form). And how will the informal plantings of shrubs and trees in the grass work - what's the concept there? How will it be maintained? Is it appropriate for this context? We definitely want to see something wonderful in this area but we aren't sure if we are seeing this correctly. How about the landscaping on the hill in front? Will that stay as is with turf? Does it relate to the landscape plan for the orchard? Is it intended that this area would be addressed in the Downtown River District Improvement Project? (If so, please make a note on the plans to avoid confusion.) Topic: Lighting Plan Number: 40 Created: 1/9/2006 [5/1/06] Thank you for addressing the lighting plan comments so well. This is one of the better lighting plans I've seen. The fixtures look great and the lighting levels are great. Please call out the ES2 fixture in final plan. Thanks for all the hard work on this. Good job! [1/9/06] Plan needs to include sketch or photo info from cut sheets for each fixture proposed. Unable to find online. Department: Engineering Issue Contact: Marc Virata Topic: Construction Plans Number: 88 Created: 4/26/2006 [4/26/06] The patching along Willow Street needs to be at right angles to the flowline and should be shown encompassing the full width of Willow Street. Number: 89 Created: 4/26/2006 [4/26/06] Why is no curb being proposed for the sidewalk along the north side of the building? It appears that parking along the north side of the building will result in the pedestrian space for the sidewalk being compromised without the curb to provide a physical barrier for the vehicles. (Follow-up: In checking with Transportation Planning, the use of curb stops mentioned at staff review should be indicated on the plans and the sidewalk will still need to be widened to 6'.) Topic: General Created: 1 /10/2006 eded from Xcel and [1 /10/06] There appears to be several outside entities that would need to provide a letter of intent for the work that is occurring on their easement/right-of-way and/or the vacating of the rights as shown on the plat. North Weld County, Xcel Energy, Colorado -Wyoming Gas Company, and United Way should provide letters of intent. Burlington Northern Railroad appears likely as grading may be occurring within their easement. Mountain States Telephone and Telegraph doesn't appear to be impacted and thus a letter of intent is likely not required. Number: 58 Created: 1/10/2006 [4/26/06] Carried over for reference. [1/10/06] With the Downtown River District Project looking into improving Willow Street and the project not designing Willow Street a dollar amount to satisfy the frontage improvement Page 2 4^z STAFF PROJECT REVIEW Cityof Rd Collins EAREN RUSSELL Date: 05/01/2006 EDAW 240 EAST MOUNTAIN AVE. FORT COLLINS, CO 80524 Staff has reviewed your submittal for NORTHSIDE ATZLAN COMMUNITY CENTER PDP - TYPE I, and we offer the following comments (two pre -hearing issues highlighted)_ ISSUES: Department: Current Planning Issue Contact: Anne Aspen Topic General Number: 27 Created: 1 /6/2006 [5/1/06] These redlines will need to be submitted at the time of Final Plan submittal, after the hearing. . [1/6/06] There are additional minor comments on the redlines. Please return all redlined plans at resubmittal. Number: 95 Created: 5/1/2006 [5/1/06] The Post Office has no further comments about this project. Topic: Site Plan Number: 24 Created: 1/6/2006 [5/1/06] The ramps still aren't making sense. See redlines. [1/6/06] The ramp system at the handicap parking areas doesn't make sense. Please see redlines. Is the small satellite parking area behind Willow Street Lofts handicap accessible. or not? Plans conflict. If so, ramps are needed. Number: 25 Created: 1 /6/2006 [5/1/06] This plot is even darker than the last. At least grey them back a bunch. [1/6/06] Please get rid of all the extraneous lines. Number: 92 Created: 5/1/2006 [5/1106] [5/1/06] Clark Mapes and I talked about the revisions you have made to the front walk area. We have some questions about the proposed. There is an existing sidewalk up at the level of the street. Is it possible to leave that as built (with a few repairs)? Then bring new sidewalks pretty much as you show them, down to the entry area? The street sidewalk serves through -walkers. I'm attaching a sketch on trace that Clark and I did. If needed, we can meet with you again about it. Topic: Landscape Plan Number: 29 Created: 1/9/2006 [5/1/06] Just carrying comment through to Final Plan [1/9/06] The print quality of page LS1.3 is poor. I am unable to review completely. At the time of Final Plan submittal, you will need to call out all specific plant materials to be used and identify them on the landscape plan. For pre -hearing review, we need enough information, possibly in the form of notes on the plans, to make sure that standards will be met. - Page 1