Loading...
HomeMy WebLinkAboutFRONT PORCH PROPERTY, 1234 W. PROSPECT ROAD - FDP - 5-06/A - CORRESPONDENCE -Sincerely, Shelby Sommer Associate City Planner Page 1 Number: 25 Created: 3/31 /2006 (5/18/06] Since no more than 750sf of drainage is allowed across a public sidewalk, you might want to construct a crosspan to divert the drainage to the east side and then construct a swale to direct the water to the sidewalk chase. Will need to construct the sidewalk chase per detail D10 and show this detail on the plan sets. See stormwater for the detail as it is not in the LCUASS. [3/31/06] Please confirm that no more than 750sf is draining across the public sidewalk. Number: 27 Created: 3/31 /2006 [5/18/06] In leiu of placing the details on the plan sets, please place a note on the plans to see drawings 701, 706, 1601, and 1602 of the Larimer County Urban Area Street Standards for driveway, curb & gutter and sidewalk requirements. [3/31/06] Please provide details 701, 702, 1601, 16b2 and 707. Number: 28 Created: 3/31 /2006 [5/18/06] A DA will not be required for this project so the repay amount will only show up when you apply for your building permit. A building permit will not be issued until the City has received the repay. [3/31/06] Please contact Matt Baker at 221-6605 for the repay owed for the Prospect Road improvements. This amount will be added into the Development Agreement and due prior to starting work. Number: 31 Created: 5/18/2006 [5/18/06] Please provide a letter from the neighboring property owner giving you permission to make the proposed improvements on their property. Number: 32 Created: 5/18/2006 [5/18/06] Label existing curb type. Dimension existing sidewalk. Do not dimension the driveway individually by lot, dimension it as a single driveway width of 27.5'. Department: Transportation Planning Issue Contact: David Averill Topic: General Number: 33 Created: 5/24/2006 [5/24/06] No comments or concerns. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 34 Created: 5/24/2006 (5/24/06] Please submit an erosion control plan per City criteria. Number: 35 Created: 5/25/2006 [5/25/06] Please provide better documentation regarding the additional impervious area. There seems to be more additional impervious area than the 893 sf stated. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. , Page 2 STAFF PROJECT REVIEW City of Fort Collins DON EARLS, PAM FOSTER, RHONDA BURRY Date: 05/26/2006 1220 W ELIZABETH ST FORT COLLINS, CO 80521 Staff has reviewed your submittal for FRONT PORCH PROPERTY, 1234 W PROSPECT ROAD PDP AND FINAL PLANS - TYPE II, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Shelby Sommer Topic: General Number: 36 Created: 5/26/2006 [5/26/06] No further comments. Please submit plans for one quick final round of review Department: Engineering Issue Contact: Susan Joy Topic: General Number: 19 Created: 3/31 /2006 (5/18/06] Thank you for adding this note as requested, however, we've just been given the "official" notice to be used where E1 and E2 are not being shown in their entirety. Please replace the earlier note with this one (without the quotes): "General Construction Notes #1 through 18, 20 through 39, and 42 through 46 as listed in Appendix E-1 of the Larimer County Urban Area Street Standards (LCUASS) shall apply and be followed for this project." "The Construction Notes under subsection Street Improvement Notes and Traffic Signing, and Pavement Marking Construction Notes in Appendix E-2 of the Larimer County Urban Area Street Standards (LCUASS) shall apply and be followed by this project as applicable." (3/31/06] Place a note on the cover sheet: See Appendix E1 and E2 of the Larimer County Urban Area Street Standards for other requirements. Number: 20 Created: 3/31 /2006 [5/18/06] Still need to label and dimension the existing UE. [3/31/06] Dimension all row from centerline. Show, label and dimension all easements. Show all utilities. Number: 22 Created: 3/31 /2006 [5/18/06] You are still treating the driveway as if its two separate driveways and not showing any information on the neighboring property. Please show the existing features as previously discussed and show how your improvements are tying into the existing. The driveway needs to be paved for the entire existing width up to the point the retaining wall starts and not just a portion thereof (as in only paving 24' wide). Grading needs to be shown for a minimum of 50' offsite to the west. See redlines or we can meet one more time if you have any questions. [3/31/06] Provide spot elevations at the flow line, property line and grade information. Maximum grade allowed for a driveway is 8%. See detail 707 for all other grade requirements. Page 1