HomeMy WebLinkAbout520 SOUTH LOOMIS ACCESSORY BUILDING - PDP - 14-06 - CORRESPONDENCE - (9)Sincerely, Shelby Sommer Associate City Planner Page 5 r' [5/25/06] Please use the City of Fort Collins standard format and language for easement dedications provided. The Fort Collins document contains certain legal language that has been provided by the City Attorney. The Fort Collins document also contains an attorney certification (completed by the applicant's attorney) and will require acceptance by the City Clerk prior to recordation. Number: 10 Created: 5/25/2006 [5/25/06] Please submit the completed, notarized standard easement document and attach the easement legal description as exhibit "A" with map exhibit "B". The exhibit "A" legal description shall bet wet stamped by a land surveyor licensed in the State of Colorado. Number: 11 Created: 5/25/2006 [5/25/06] Add the township, section description to the legal description in exhibit "A" and title on the exhibit "B" map. Department: Natural Resources Topic: General Number: 1 [5/23/06] No issues. Issue Contact: Doug Moore Created: 5/23/2006 Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 22 Created: 6/13/2006 [6/13/06] ACCESS: The length of the lot (from street curb to the east end of the lot) shown in the newer plans differs from the original drawing presented at Conceptual Review April 20. The original drawing showed 190 feet length; the drawing for Staff Review shows 210 feet. Based on the newer drawing, the accessory building is out of access (best estimation is approximately 162 feet from the street, as the hose lies) and therefore will require automatic fire sprinklers. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 25 Created: 6/14/2006 [6/14/06] No comments. Department: Zoning Issue Contact: Jenny Nuckols Topic: General Number: 21 Created: 6/1 /2006 [6/1/06] There can be no kind of cooking unit in the structure at all, this includes microwave oven, hot plate etc Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Page 4 (Site or Grading plan) with address and legal description in smaller text below (see red -line comments). Number: 3 Created: 5/25/2006 [5/25/06] The Grading Plans shall contain the City's standard General Notes, Construction Notes (grading & erosion control), standard indemnification statements and standard note regarding damaged sidewalk, curb & gutter. A City standard approval signature block shall be placed on the lower right comer of each plan sheet. A project vicinity map shall be placed on the Site & Grading plans showing site location with respect to major surrounding streets. All of the standard notes have been provided to you with the red -line comments. Number: 4 Created: 5/25/2006 [5/25/06] Show and label the proposed 8 foot utility easement adjacent to the alley. Number: 5 Created: 5/25/2006 [5/25/06) Show on the grading plans how the proposed new building will be connected to water, sewer and power services. Number: 6 Created: 5/25/2006 [5/25/06] Using arrows, please show the surface drainage patterns around all sides of the proposed building and into the alley. No drainage is permitted to cross property lines which may adversely affect adjacent properties. Drainage shall be conveyed to the alley in a way that does not create ponding or erosion problems within the alley. Number: 7 Created: 5/25/2006 [5/25/06] Please show the width dimension of the existing sidewalk on Loomis Street on the Site Plan. Number: 8 Created: 5/25/2006 [5/25/06] Under Section 3.6.2 J(2) you are exempt from having to make any improvements to the alley for your project at this time however, the City will require you to enter into a development agreement which essentially requires you to pay for your portion of the alley improvements (alley frontage) in the future if the alley is improved by the City or by another developer. Please complete and return the attached City of Fort Collins Information for Development Agreements form with your next submittal. A draft development agreement has been attached for your review. Topic: Technical Services Number: 30 Created: 6/14/2006 [6/14/06] No Comments Topic: Utility Easement Number: 9 Created: 5/25/2006 Page 3 Number: 19 Created: 5/30/2006 [5/30/06] Is there a walkway connecting the accessory building to primary residence? Please indicate where/what type on site plan. Number: 20 Created: 5/30/2006 [5/30/06] Dennis Greenwalt (Comcast): The 8 foot utility easement is not visible on the site plan. Please indicate where this easement will be. Number: 23 Created: 6/13/2006 [6/13/06] Neighborhood Services: No concerns. Number: 24 Created: 6/13/2006 [6/13/06] Karen McWilliams (Historic Preservation): No issues with this proposal. Number: 26 Created: 6/14/2006 [6/14/06] Based on the floor plan this appears to be a dwelling unit. No kitchen facilities are allowed in accessory buildings with habitable space. Number: 27 Created: 6/14/2006 [6/14/06] The minimum pitch of the roof shall be 2:12 unless the proposed pitch (1:12) matches the existing single-family building (Division 4.7(F)(1)(g)). Number: 28 Created: 6/14/2006 [6/14/06] The exterior eave height should not exceed 13 feet from grade, and the height of the accessory building shall not exceed 24 feet (Division 4.7(F)(2)). With the grading as proposed, the building and eave heights actually appear to exceed these maximums. Number: 29 Created: 6/14/2006 [6/14/06] Please contact the Electric Utility at 221-6700 to locate your existing electric utility lines. Please show the location of these lines on the site plan. If the line needs to be relocated due to the placement of the accessory building, you (the applicant) will be responsible for the relocation costs. Number: 31 Created: 6/15/2006 [6/15/06] Can the existing chain link fence and/or the few stairs in the back yard be removed? With the new fence along the perimeter of the property, what purpose does this fence serve? Separating the two structures this way makes it appear to be a separate dwelling unit rather than an accessory building for the main house. Department: Engineering Issue Contact: Randy Maizland Topic: General Number: 2 Created: 5/25/2006 [5/25/06] Please separate the Site Plan and Grading Plan into two individual sheets, 24 x 36 inches in size. At the top center of each sheet, label with title in large text Page 2 STAFF PROJECT REVIEW City of Fort Collins CHARLES & BEVERLY KOHL Date: 06/20/2006 2037 ANGELO DRIVE FORT COLLINS, CO 80528 Staff has reviewed your submittal for 520 SOUTH LOOMIS ACCESSORY BUILDING PDP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Shelby Sommer Topic: General Number: 12 Created: 5/30/2006 [5/30/06] Rick Lee (Building Department) has attached the applicable Building Codes and Standards. Number: 13 Created: 5/30/2006 [5/30/06] Please show more contextual information (le. The street name in the appropriate location and the approximate location of any neighboring structures near the proposed accessory building). Number: 14 Created: 5/30/2006 [5/30/06] Please show the proposed driveway on the site plan in addition to the grading plan. Number: 15 Created: 5/30/2006 [5/30/06] Please label all items or use a key to differentiate between shading styles and symbols (ie. Fence, grass, lights, concrete... ) Number: 16 Created: 5/30/2006 [5/30/06] Please include the following signature blocks on the site plan: Owner's Certification Block and Director of Planning Block. Number: 17 Created: 5/30/2006 [5/30/06] Please add a Land Use Information box with the existing zoning, lot size and building coverage. Minimum lot area shall be the equivalent of two times the total floor area of the buildings (Division 4.7(D)(1)). Also, lots are subject to a maximum Floor Area Ratio (FAR) of .33 on the rear 50 percent of the lot (Division 4.7(D)(5)). Please confirm these calculations within the Land Use Information box. Number: 18 Created: 5/30/2006 [5/30/06] The second story appears to be 7 1/2 feet in height. In order for this area not to be counted as "floor area," it must be less than 71/2 feet. Accessory buildings with habitable space in the NCM zoning district shall contain a maximum of 600 square feet of floor area. Page 1