HomeMy WebLinkAboutFRONT PORCH PROPERTY, 1234 W. PROSPECT ROAD - PDP - 5-06 - CORRESPONDENCE - (5)Number: 3 Created: 3/8/2006
[3/8/06] In the Project Notes section, make mention that trash will be picked up curb side
weekly - etc. It is noted in the Planning objectives letter, but also needs to be on the site
plan itself.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
Tmbqpa*La�
Shelby Sommer.
Associate City Planner
Page 4
Topic: Traffic Study
Number: 23 Created: 3/31 /2006
[3/31/06] Has Eric Bracke with Traffic Engineering waived the Traffic Study or is it still
required? If still required, please provide a copy of it to the Engineering Dept.
Department: Light & Power Issue Contact: Doug Martine
Topic: Light & Power
Number: 1 Created: 3/6/2006
[3/6/06] The existing electric utility system is designed for a maximum service to this
property of 125 amps. If additional power is required, contact Light & Power Engineering to
determine the electric development and system modification charges that will apply. The
owner will need to contact the Utility Billing office (221-6785) to change the electric rate from
residential to commercial.
Department: Natural Resources
Topic: General
Number: 5
[3/9/06] No issues.
Issue Contact: Doug Moore
Created: 3/9/2006
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 14 Created: 3/30/2006
[3/30/06] ADDRESS: Address numerals shall be visible from the street fronting the property,
and posted with a minimum of six-inch numerals on a contrasting background. (Bronze
numerals on brown brick are not acceptable).
Number: 15 Created: 3/30/2006
[3/30/061 WATER SUPPLY: A fire hydrant is required. Minimum flow and spacing
requirements are 1,500 gpm at 20 psi residual pressure, not more than 300 feet from the
structure.
Number: 16 Created: 3/30/2006
[3/30/06] ACCESS: The private drive from Prospect Road to the structure shall be an all-
weather surface (asphalt or concrete), capable of supporting fire apparatus weight.
Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan
Topic: Stormwater
Number: 12 Created: 3/28/2006
[3/28/06] The additional increase in impervious area is less than 1000 square feet, no
detention or water quality reqired.
Topic: WaterMastewater
Number: 13
[3/28/06] No Comments.
Created: 3/28/2006
Department: Zoning Issue Contact: Jenny Nuckols
Topic: ZONING
Number: 2 Created: 3/8/2006
[3/8/06] handicap parking space needs to be 16 wide and signed as van assessible as well
as handicapp accessible.
Page 3
Number: 21 Created: 3/31/2006
[3/31/06] As stated at the Conceptual Review, parking setbacks apply in accordance with
figure 19-6. Minimum parking setback for this project is 50' from flowline and it appears to
effect the first parking spot. You can either remove the spot entirely or move the parking
stalls north to meet the standard.
Number: 28 Created: 3/31/2006
[3/31/06] Please contact Matt Baker at 221-6605 for the repay owed for the Prospect Road
improvements. This amount will be added into the Development Agreement and due prior
to starting work.
Number: 29 Created: 3/31/2006
[3/31/06] This driveway must be rebuilt in accordance with drawing 707 (radial curb returns,
minimum 24' width and maximum grades apply).
Number: 30 Created: 3/31/2006
[3/31/06] The project ID sign may not be located within the 15' utility easement.
Topic: Grading
Number: 22 Created: 3/31/2006
[3/31/06] Provide spot elevations at the flow line, property line and grade information.
Maximum grade allowed for a driveway is 8%. See detail 707 for all other grade
requirements.
Number: 24 Created: 3/31/2006
[3/31/06] Please provide spot elevations for TOW and BOW along the proposed concrete
wall.
Number: 25 Created: 3/31/2006
[3/31/06] Please confirm that no more than 750sf is draining across the public sidewalk.
Topic: Pavement Management
Number: 17 Created: 3/31/2006
[3/31/06] Rick Richter with Pavement Management has reviewed your project and has no
concerns.
Topic: Scanning
Number: 26 Created: 3/31/2006
[3/31/06] See Appendix E6 for all scanning requirements. For instance, the shaded areas
will not scan.
Number: 27 Created: 3/31/2006
[3/31/06] Please provide details 701, 702, 1601, 1602 and 707.
Topic: Technical Services
Number: 18 Created: 3/31/2006
[3/31/06] J.R. Wilson with Technical Services has no comments as there is no plat with this
project.
Page 2
I
STAFF PROJECT REVIEW
Citvof Fort Collins
DON EARLS, PAM FOSTER, RHONDA BURRY Date: 03/31/2006
1220 W ELIZABETH ST
FORT COLLINS, CO 80521
Staff has reviewed your submittal for FRONT PORCH PROPERTY, 1234 W PROSPECT
ROAD, CHANGE OF USE, PDP - TYPE 11, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Shelby Sommer
Topic: Genera/
Number: 6 Created: 3/20/2006
[3/20/06] See the Building Department comment sheet for Building Code details.
Number: 7 Created: 3/20/2006
[3/20/06] It appears that the existing garage and carports are going to be used for additional
parking. If this is the case, you have exceeded the maximum number of spaces allowed for
a general office use. Please indicate on the site plan if the garages are for storage only.
Otherwise you will need to pursue an exception to the General Office Parking Standard, per
Section 3.2.2(K)(4).
Number: 8 Created: 3/20/2006
[3/20/06] How high is the proposed retaining wall on the west property line? What sort of
materials are to be used? And the fence above the retaining wall?
Number: 9 Created: 3/20/2006
[3/20/06] Please plant a landscape buffer along the east side of the walkway (across from
the parking stalls) to screen/shield the cars' headlights for the neighbor to the east.
Number: 10 Created: 3/22/2006
[3/22/06] Rick Lee (Building Department): Please find attached the various codes that the
Fort Collins Building Department will enforce. The information submitted is very limited and
we require that a pre -submittal meeting be scheduled before the Construction Documents
proceed too far. For a change of occupancy (residence to office) the more challenging code
components are accessibility and structural capability. We need to get into the building with
a wheel chair and use a toilet room. The first parking stall shall be van accessible which has
an eight foot load -isle not the five feet that you have indicated. The maximum slope for a
ramp is 1:12 or one foot of ramp for every inch of rise. You may'want to consider the back
door to be the accessible route using a sloped walk (1:20) rather than a ramp.
Department: Engineering Issue Contact: Susan Joy
Topic: Genera{
Number: 19 Created: 3/31/2006
[3/31/06] Place a note on the cover sheet: See Appendix E1 and E2 of the Larimer County
Urban Area Street Standards for other requirements.
Number: 20 Created: 3/31/2006
[3/31/06) Dimension all row from centerline. Show, label and dimension all easements.
Show all utilities.
Page 1 .