Loading...
HomeMy WebLinkAboutFREY STREET COTTAGES SUBDIVISION - FDP - 17-06/A - CORRESPONDENCE - (5)Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 27 Created: 7/21 /2006 [2/21 /07] [1/5/07] Repeat Comment [9/14/06] 1 can help coordinate this meeting. [7/21/06) The invert of the detention pond needs to be higher than the normal operating water level in the Larimer County Canal #2. Verification from a Larimer County Canal #2 representative of this water level is required. I suggest a meeting at the site with all necessary representatives to determine this elevation. /otdrdss2d a,\ Ska-aA- 4, Lrenpe^� dJofe #2 Number: 44 Created: 7/28/2006 [2/23/07] [1/5/07] Reminder Comment. [9/14/06] Reminder comment. [7/28/06] The Larimer County #2 Canal company will need to approve and sign the utility plans. OK_ Number: 78 Created: 1 /5/2007 [2/23/07] [1/5/07] Please use the current revised water quality outlet structure detail. An electronic copy can be emailed to you. DL Number: 79 Created: 1 /5/2007 [2/23/07] [1/5/07] Please coordinate with the Stormwater Department on the detail for the area inlets. Electronic Inlet details can be emailed as well. Or — Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterlWW Number: 57 Created: 9/8/2006 [2/12/07] (Repeat comment... again) [1/2/07] (Repeat comment) [9/8/06] Move area inlet in Frey to provide 5 feet (minimum) separation from the existing water main. PC Besure and return all of your redlined plans when you re -submit. I will not require a formal submittal to wrap this project up but you must submit directly to me 5 sets of plans, redlines and responses to this comment sheet for the above reviewers to review. We will need two weeks to review. Assuming all issues have been addressed, we will let you know that you are ready to proceed to mylars. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6206. Sincerely, Arine H. en/ City Planner Page 3 [1/8/07] Please provide radii and all spot ele ations per LCUASS Figure 7-27 at the intersection of Frey & LaPorte.1Wed to Number: 88 Created: 1 /8/2007 [2/6/07] Repeat comment. [1/8/07] Show and label the approximate limits of street cut to construct Frey where it ties into Laporte. Please add the City standard street cut note to the Frey Street Plan. Note is attached to the redlines. More No� -*- sa.wcc,,A shoa.a�. Number: 90 Created: 2/5/2007 [2/5107] Please refer to sheet 6, street design for Frey Street - The City has determined that the elevations on Laporte will be slightly lower when the street is reconstructed in the near future. A design elevation of 5047.79 was provided to you prior to the last submittal which is the future elevation at the westerly PC on the southwest corner. You will need to design and build to that future elevation for the drainage to work properly once Laporte is reconstructed by the City. Please revise the plan to show this elevation and how the new curb and gutter will tie back into the existing curb and gutter on Laporte. !e4ANep Number: 91 Created: 2/6/2007 [2/6/07] Please call out the new proposed H.C. ramps with LCUASS standard drawing 1606 on the street plan for Frey Street. A"4 Number: 92 Created: 2/6/2007 [2/6/07] Please remove the intersection detail LCUASS drawing no. 708 and replace with Figure 7-28 detail. �r,e Number: 93 Created: 2/6/2007 [2/6/07] Need to add a type 11 barricade at the end of the sidewalk on Frey. Topic: Technical Services Number: 98 Created: 2/14/2007 [2/14/07) Please add a reference note to the Plat regarding allowable uses within the wildlife buffer zone. See redlines for note language and code reference. bene Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 97 Created: 2/13/2007 [2/13/07] PFA has no further comments or concerns. Department: Stormwater-Water-Wastewater Issue Contact: Glen Schlueter Topic: Stormwater Number: 99 Created: 2/23/2007 [2/23/07] Red lines were not returned for the Feb. submittal. A drainage report was requested last week but was not submitted to Stormwater so the Engineering copy was reviewed. There was no mention of verification of the outfall depth and no discussion of why the cross pan was removed allowing water off of LaPorte to drain onto Frey. This change requires changes to the drainage analysis. I had a phone conversation with Jerry from Stewart and Associates when we requested the drainage report. He thought Wes had made the comment to remove the cross pan at Laporte. Wes didn't make that comment so we are not sure how Jerry thought that. He told me that he saw a redline comment so I guess we need to see the redlines. nQQ�tn P��d(4SJ, RRA 1+ 0 r o u(- 4 (( 1 S a n sips i-4 u, Cn k",r4 N0,t*- *2 Page 2 STAFF PROJECT REVIEW Citvoi Fort Collins JACK BLAKE Date: 02/23/2007 STEWART AND ASSOCIATES 103 S. MELDRUM ST. FORT COLLINS, CO 80521 Staff has reviewed your submittal for FREY AVE. COTTAGES SUBDIVISION PDP - TYPE I AND FINAL PLANS, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Anne Aspen Topic: General Number: 94 Created: 2/12/2007 [2/12/07] The following departments/agencies have no further comments at this time: Comcast, GIS, County Assessor, Xcel Energy and Forestry. Number: 95 Created: 2/13/2007 [2/13/07] Xcel Energy comments as follows: "Existing 4" MW gas main lays 21' west of east property line of Frey Street." Topic: Site Exhibit Number: 96 Created: 2/13/2007 [2/13/07] Maximum height in the NCL zone is 2 stories, not 30 feet. A story is defined in the Land Use Code as no more than 12.5 feet, so the maximum height in feet would be 25 feet._ Department: Current Planning Issue Contact: Dana Leavitt Topic: Landscape plan Number: 75 Created: 1 /2/2007 [2/2/07] Address protection of significant existing trees where other trees will be removed. Several trees to be removed are very close to trees to remain. Need to identify protection measures specifically for such trees. [1/2/07] Describe tree protection methods in areas where other trees are to be removed. Need to ensure that removing one tree does not damage another tree. Department: Engineering Issue Contact: Randy Maiziand Topic: Engineering Number: 85 Created: 1 /8/2007 [2/6/07] Drainage report does not address flows coming off of Laporte going into the new proposed inlet on Frey.-� -ioes no+ go -[o (n.(-'AS an, to,j-.er. [1/8/07] If Laporte drainage is intended to be conveyed to Frey and into the proposed inlet, have the inlets and storm drain been sized to carry these flows? Please provide hydrology calc's to verify this. Number: 86 Created: 1 /812007 [2/6/07] Intersection has changed to a T intersection without a pan. Still need to show all spot elevations and dimensions per LCUASS 7-28. You can show this on the current plan or provide a separate intersection detail showing all of the required elevation, dimension and slope information. TiotW j�Aa V_,e� ojjpcl aja., - o pry jcc:- &L-� tD #Vkj� '7- Z 6 rTertrA2n5 Page 1