HomeMy WebLinkAboutFREY STREET COTTAGES SUBDIVISION - FDP - 17-06/A - CORRESPONDENCE -weights; compacted road base shall be used only for temporary fire lanes or at construction sites. The fire lane must have appropriate maintenance agreements that are legally binding and enforceable. It is required to be designated on the plat as an Emergency Access Easement. The required minimum width of 20 feet must be maintained throughout the length of the fire lane. If a fire lane cannot be provided, the building shall be fire sprinklered. If the fire lane exceeds 150 feet in length, a turnaround must be provided with appropriate turning radii. Contact Carte Dann at PFA for more information. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 27 Created: 7/21 /2006 [1/5/07] Repeat Comment [9/14/06] 1 can help coordinate this meeting. [7/21/06] The invert of the detention pond needs to be higher than the normal operating water level in the Larimer County Canal #2. Verification from a Larimer County Canal #2 representative of this water level is required. I suggest a meeting at the site with all necessary representatives to determine this elevation. Number: 44 Created: 7/28/2006 [1/5/07] Reminder Comment. [9/14/06] Reminder comment. [7/28/06] The Larimer County #2 Canal company will need to approve and sign the utility plans. Number: 78 Created: 1 /5/2007 [1/5/07] Please use the current revised water quality outlet structure detail. An electronic copy can be emailed to you. Number: 79 Created: 1 /5/2007 [1/5/07] Please coordinate with the Stormwater Department on the detail for the area inlets. Electronic Inlet details can be emailed as well. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WatedWW Number: 57 Created: 9/8/2006 [1/2/07] (Repeat comment) [9/8/06] Move area inlet in Frey to provide 5 feet (minimum) separation from the existing water main. Be sure and return all of your redlined plans when you re -submit. Revision submittal requirements are listed on the attached revision routing sheet. I will reduce the next round of review turn -around time to 2 weeks since the remaining issues are relatively minor. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6206. Si rely, Pnqse Planner Page 3 Number: 82 Created: 1 /8/2007 [1/8/07] Refer to the Plat: Please label the 9 foot and 15 foot easements adjacent to Frey and LaPorte as Utility Easements. Remove drainage from the label. Indicate on the Plat who will own and maintain Tract A. Number: 83 Created: 1 /8/2007 [1/8/07] Refer to the Overall Utility Plan sheet: Please show and label the existing and proposed ROW on both Frey and LaPorte. Label items shown on the redlines. Number: 84 Created: 1 /8/2007 [1/8/07] Street design: The drainage pan at the intersection of Frey & LaPorte will not drain properly with the proposed elevations being shown. A minimum of 0.5% flowline gradient needs to be maintained across the pan if LaPorte drainage is to be conveyed east to the canal. If LaPorte drainage is to be conveyed around the corner and down Frey Street to the new inlet, a minimum fall of 0.5% must be maintained around the comer for adequate drainage. If drainage is being conveyed to the Frey inlet, will a pan even be needed ? Please analyze the drainage at the intersection and modify elevations as needed. Number: 85 Created: 1 /8/2007 [1/8/07] If LaPorte drainage is intended to be conveyed to Frey and into the proposed inlet, have the inlets and storm drain been sized to carry these flows ? Please provide hydrology calc's to verify this. Number: 86 Created: 1/8/2007 [1/8/07] Please provide radii and all spot elevations per LCUASS Figure 7-27 at the intersection of Frey & LaPorte.. Number: 87 Created: 1 /8/2007 [1/8/07] For the off -site street design of Frey Street to the south, no single point grade breaks of greater than 0.4% are allowed. Please show design point grade brakes and provide vertical curve data if necessary. Number: 88 Created: 1 /8/2007 [1/8/07] Please add the City standard street cut note to the Frey Street Plan. Note is attached to the redlines. Number: 89 Created: 1 /8/2007 [1/8/07] Please label the vertical curve distances on the profiles. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 41 Created: 7/26/2006 [1/3/07] There is no emergency access easement on the plat. Building 5 is therefore out of access. Please plat the EAE OR equip Building 5 with an approved, automatic fire -sprinkler system. If you choose to install the automatic sprinklers, that must be noted on the final plans. [7/26/06] REQUIRED ACCESS: A fire lane is required. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. The fire lane must be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus Page 2 STAFF PROJECT REVIEW Citvof Fort Collins JACK BLAKE Date: 01/08/2007 STEWART AND ASSOCIATES 103 S. MELDRUM ST. FORT COLLINS, CO 80521 Staff has reviewed your submittal for FREY AVE. COTTAGES SUBDIVISION PDP - TYPE I AND FINAL PLANS, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Anne Aspen Topic: General Number: 45 Created: 7/31/2006 [1/8/07] [7131/06] The Post Office reminds you that you will need to provide adequate mail receptacles at the front of the property. Number: 80 Created: 1 /8/2007 [1/8/07] The following departments indicate that they have no further concerns with the proposed project: Comcast, Larimer Canal #2, Zoning, and Park Planning. Topic: Landscape plan Number: 50 Created: 7/31/2006 [1/8/07] 1 have not received comments from Tim. Have you met with him already? If not, please schedule a site visit with him. [7/31/06] Contact City Forester Tim Buchanan at 221-6361 to schedule a site visit. The existing trees need to be examined to see if they have significance. If so, mitigation will be required, including additional trees or upsizing proposed trees. Department: Current Planning Issue Contact: Dana Leavitt, Environmental Planner Topic: Landscape plan Number: 73 Created: 1 /2/2007 -[1/2/07] Bottom of detention pond needs to have "water tolerant" grass varieties. Add to native grass list and delineate limits of water tolerant seed mix within detention pond on landscape plan. Number: 75 Created: 1 /2/2007 [1/2/07] Describe tree protection methods in areas where other trees are to be removed. Need to ensure that removing one tree does not damage another tree. Number: 77 Created: 1 /3/2007 [1/3/07] There is a street light on comer of Frey and Laporte. Ensure that street trees have a 40' separation. Department: Engineering Issue Contact: Randy Maiziand Topic: Engineering Number: 81 Created: 1/8/2007 [1/8/07] Please update the date on the cover sheet to January 2007. Page 1