HomeMy WebLinkAboutMENNING SUBDIVISION - PDP - 25-06 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWCOFFEY ENGINEERING & SURVEYING, L.L.C.
903 E. Grand Avenue, Laramie, Wyoming 82070 • admin@wyocoffey.com • 307.742.7425 • Fax: 307.742.7403
WATER WASTEWATER — An easement for the sewer line from the existing residence
to Juniper Court has already been recorded, and is shown on the plat and extended to
meet proposed property lines.
LIGHT AND POWER — A utility easement from Juniper to the lot with the existing
residence has already been recorded and is shown on the plat.
ADVANCE PLANNING — Photographs of the existing residence will be provided at the
time of building permit appli tion or a new residence. i
r
COFFEY ENGINEERING & SURVEYING, L.L.C.
903 E. Grand Avenue, Laramie, Wyoming 82070 • admin@wyocoffey.com • 307.742.7425 • Fax: 307.742.7403
MENNING SUBDIVISION
RESPONSE LETTER
JUNE 26, 2006 CONCEPTUAL REVIEW
ZONING — All requirements discussed by zoning will be met. There shall be a
minimum of two off-street parking spaces for the proposed residence.
CURRENT PLANNING — Landscaping and parking requirements will be met. The
submittal of the plans for building permit will include more detail as to how these
standards will be satisfied.
ENGINEERING — Additional right of way may be required for La Porte Street;
currently the right of way if 30-foot half width. If eight feet additional is required, that
would reduce the front setback for the existing residence less than twenty
The existing sidewalk on La Porte is an attached 2-foot-wide sidewalk for the subject
property and a majority of the adjoining properties. There currently is not sidewalk
adjacent to the property for Juniper Court. A 4-foot wide sidewalk exists on the adjacent
property to the west, and no sidewalk on the property to the east.
Utilities have already been relocated to serve the existing residence. Utilities necessary
for the proposed residence will be service lines only, and will be addressed at building
permit application.
TRANSPORTATION PLANNING — The required sidewalk along Juniper Court has
been shown on the grading plan. The sidewalk along La Porte will need to be discussed
after review of the project.
POUDRE FIRE AUTHORITY —Fare by ant location will be addressed as the review
process proceeds.
STORMWATER — After a phone conversation with Glen Schlueter, a preliminary
grading plan was produced and included in the submittal packet to show that it is possible
to drain the proposed lot to the street. The proposed increase in imperviousness will be
less than 5000 square feet and a drainage study was not prepared, not on -site detention is
required.
The proposed new residence will drain to Juniper Court, and not onto the adjacent lots.
Concrete pans may be required to accomplish this, to be installed and designed at the
time of building permit application and construction.