Loading...
HomeMy WebLinkAboutUNITED WAY HOUSING SERVICES DAY CENTER - PDP - 30-06 - CORRESPONDENCE -Number: 8 Created: 11 / 7 / 2006 [11/7/06] Please label the property lines on the Site Plan Number: 9 Created: 11 / 7/ 2006 [11/7/06] West elevation suggestion: Use the same window configuration on each side of the entrance to keep a symmetrical look. Number: 10 Created: 11 / 7/ 2006 [11/7/06] Elevations depict the main entrance on the west side with a double door. The Site Plan shows the west side with a single door. Please clarify. It has been determined that this development request could possibly be placed on the agenda for the January 18, 2007 Planning & Zoning Board public hearing. However, there are some issues and concerns with various City departments that must be addressed before this item could go to the Board. This could be done through another formal round of review (if re- submitted quickly) or by working directly with the appropriate representatives of the departments. Staff will be setting the P 8v Z Board agenda on December 20, 2006. Be sure and return all red -lined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, Awc5w Steve Olt City Planner cc: Susan Joy, Engineering ... 221-6605 Jenny Nuckols, Zoning ... 416-2313 Janet McTague, Light & Power ... 224-6154 Carie Dann, Poudre Fire Authority ... 416-2869 Roger Buffington, Water/Wastewater ... 221-6854 Wes Lamarque, Stormwater ... 416-2418 Current Planning file #30-06 Page 9 Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 32 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Label all waterline fittings, valves, etc. Indicate length of water line segments between valves, fittings, etc. Number: 33 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Move curb stop out of sidewalk and to within 2 ft of meter pit. Curb stop must be in easement or R.O.W. Number: 34 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Each building must have separate water and sewer services. Will services be stubbed in for the future building? Number: 35 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Is separate irrigation tap planned? Number: 36 Created: 11 / 21 / 2006 [ 11 /21 /06] See plans for other comments. Department: Zoning Issue Contact: Jenny Nuckols Topic: ZONING Number: 2 Created: 11 / 7 / 2006 [ 11 / 7 / 06] Please remove topography lines from the final Site Plan. Number: 3 Created: 11 / 7 / 2006 [ 11 / 7 / 06] Please show and label the building envelope and footprint on the Site Plan. Number: 4 Created: 11 / 7 / 2006 [11/7/06] How tall will the masonry wall be around the play area. Number: 5 Created: 11 / 7/ 2006 [11/7/06] There are no handicap spaces called out on the Site Plan. Please label and note dimensions of HC spaces. NOTE: There must be at least on van accessible space with an overall width of 16 feet. Number: 6 Created: 11 / 7/ 2006 [11/7/06] What type offence is proposed around the existing storage areas near the trash enclosure? Number: 7 Created: 11 / 7 / 2006 [11/7/06] Provide a bike rack near the main entrance and note its location on the Site Plan. Page 8 Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Floodplain Number: 30 Created: 11 / 21 / 2006 [ 11 / 21 / 06] The City's Dry Creek floodplain will be revised in the near future and this revision will remove the site form the 100-year floodplain. The site still will be partially in the FEMA 500-year floodplain until the Physical Map Revision is approved by FEMA in approximately 2 years. Number: 31 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Please show and label FEMA 500-year floodplain on the plat and drainage plan. Topic: Stormwater Number: 25 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Please discuss in detail the reasoning behind this site only detaining for on -site runoff and not off -site runoff from the north and west. In the discussion, describe where the other lots that are undeveloped will detain and outfall. This is needed because this proposal is changing the existing design for all 4 of these lots. Please discuss how the interim (existing) undeveloped off -site flows will drain. This site may need to route these off -site flows through the site. Please remove discussion with City Staff in the text and only include the explanations. Number: 26 Created: 11 / 21 / 2006 [ 11 / 21 / 061 The .06 cfs release rate for the detention pond is impractical (being less than the water quality release rate) and also will probably have clogging problems. It is suggested that you request a variance to allow basin F to release undetained and keep the detention pond release rate equal to the site release rate of .36 cfs. This will allow for a practical release and still provide adequate detention and still improve the situation for the regional downstream drainage system. Number: 27 Created: 11 / 21 / 2006 [ 11 / 21 / 06] The minimum size for storm sewers is 15 inches. This is for clogging purposes. Please revise storm sewers 2 and 3 to 15 inches. Storm sewer 1 can stay at 10 inches as the drainage area is extremely small. Number: 28 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Please use the City standard water quality outlet structure detail. I can email you this new detail. Number: 29 , Created: 11 / 21 / 2006 [ 11 / 21 / 06] Please change the text on the plat to read Drainage Easement, not Detention Pond Easement. Page 7 Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 47 Created: 11 / 21 / 2006 [ 11 / 21 / 06] FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2.1 and PFA Bureau Policy Number: 48 Created: 11 / 21 / 2006 [ 11 / 21 / 06] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire. Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Spacing and flow requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter. 97UFC 901.2.2.2 Number: 49 Created: 11 / 21 / 2006 [ 11 / 21 / 06] KNOX BOX REQUIRED: Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97UFC902.4; PFA BUREAU POLICY 88-20 Number: 50 Created: 11 / 21 / 2006 [ 11 /21 / 06] ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of six-inch (6) numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 97UFC 901.4.4 Number: 51 Created: 11 / 21 / 2006 [11/21/061 ASSEMBLY AREAS: Will any areas of the building be considered an Assembly Occupancy? Number: 52 Created: 11 / 22 / 2006 [11/22/06] TURNING RADII: Minimum turning radii (drive aisle) is 25 feet inside, 50 feet outside. Department: Traffic Operations Issue Contact: Eric Bracke Topic: Traffic Number: 1 Created: l l / 1 / 2006 [ 11 / 1 / 06] No issues or concerns from Traffic Operations. The TIS is accepted. R Page 6 N Number: 41 Created: 11 / 21 / 2006 [ 11 / 21 / 06] See redlines. Topic: Utility Plans Number: 42 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Cover Sheer -Project title is incorrect. Provide 2 benchmarks. Add line 49 and reference the soils report. Provide a soils report. Corrections required to line 19 and 40. Number: 43 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Sheet 2 - Add notes from E2. Number: 44 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Remove the word "min" when dimensioning row, etc. Must dimension the actual. Number: 45 Created: 11 / 21 / 2006 [ 11 / 21 /06] Grading plan - label all slope ratios. Grades behind a public walk need to be flat to nearly flat for a minimum of two feet. Label TOW and BOW. Depending on height of retaining wall, details may be required. A sidewalk chase is proposed in the ramp off Conifer and needs to be moved. A 12" HDPE storm pipe is shown terminating at the detention pond - please add the appropriate FES or will this be a "weep hole" in the wall? Number: 46 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Telephone pedestals, electric vaults, etc are shown in the sidewalk. Are these existing? Proposed? Will need to move some of them. Department: Light & Power Issue Contact: Janet McTague Topic: General Number: 11 Created: 11 / 9 / 2006 [11/9/06] Need to coordinate a transformer location within 10 feet of a paved surface. Number: 12 Created: 11 / 9 / 2006 [11/9/06] We'll need a C-1 form indicating electrical requirements for the building. Number: 13 Created: 11 / 9 / 2006 [11/9/061 Relocation of existing electric facilities, if necessary, is paid for by the developer. Page 5 Number: 19 Created: 11 / 20 / 2006 [11/20/061 The correct row, parkway widths, sidewalk & utility easements were not dedicated and designed. Please see 7-5F for Conifer and 7-6F for Blue Spruce. You have the option of dedicating additional row to the back of the sidewalk or dedicating an access easement, whichever is acceptable to you. There are pros and cons to each. Number: 20 Created: 11 / 20 / 2006 [11/20/061 Grades behind a public sidewalk need to be flat to nearly flat for a minimum of 2'. Label all slope ratios on the grading sheet. Number: 21 Created: 11 / 20/ 2006 [11/20/061 Both driveways need to be designed and SHOWN on the plans in accordance with 706. Number: 22 Created: 11 / 20 / 2006 [ 11 / 20 / 06] Please label all easements as "proposed" or "existing". Number: 23 Created: 11 / 20/ 2006 [11/20/061 The emergency access easement requires a 50' outside turning radius and 25' inside turning radius. Number: 24 Created: 11 / 20 / 2006 [11/20/061 The Horizontal Control Plan is missing a lot of information. Please dimension all sidewalks, parkways, row, UE's (existing and proposed), parking stall widths and lengths (or label as typical if typical), etc. Number: 37 Created: 11 / 21 / 2006 [ 11 / 21 / 06] You can vacate the access easements for the shared driveways by this plat and not worry about vacating the easement on the neighboring property. Those property owners can do that when they (re)develop. Number: 39 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Show existing features (driveways, sidewalks, etc) within 150' of the project boundaries (all plan sets). Number: 40 Created: 11 / 21 / 2006 [ 11 / 21 / 06] There are no sight distance easements required with this project. Sight distance easements are only required where they fall outside the row and this is not happening with this project. Topic: Site Plan Number: 38 Created: 11 / 21 / 2006 [ 11 / 21 / 06] Remove all contours. Page 4 way. Therefore, a request for a modification of this standard must be submitted for review by staff and the Planning and Zoning Board. * Please reference Section 2.8.2(H) of the Land Use Code for the criteria to use in the requests for modifications of the standards. Number: 61 Created: 11 /28/2006 [11/28/061 The details at the bottom of the Site Plan need to be slightly enlarged to make them legible. Number: 62 Created: 11 / 28/ 2006 [11/28/061 On the Vicinity Map, East Vine Drive does not run north - south east of the SITE. That street actually is Redwood Street. Topic: Subdivision Plat Number: 67 Created: 11 / 28 / 2006 [11/28/06] If the Building Envelopes as shown on the subdivision plat would need to be changed in the future then a formal replat of the property, going to a public hearing, would be required. The plat cannot be changed administratively through the Minor Amendment process. Topic: Utility Plans Number: 70 Created: 11 / 28 / 2006 [11/28/061 Len Hilderbrand of Xcel Energy indicated that they will need to open a street cut to install a new gas service to this development. There is a 6" MW gas main in Blue Spruce Drive. Department: Engineering Issue Contact: Susan Joy Topic: General Number: 14 Created: 11 / 20 / 2006 [11/20/061 Please title ALL plan sets "United Way Housing Services Day Center". Number: 15 Created: 11 / 20 / 2006 [ 11 / 20/ 06] There were a lot of comments given at the initial conceptual review that were not addressed with this submittal. More detailed comments to follow with Final Compliance. Number: 16 Created: 11 / 20/ 2006 [11/20/061 The plan sets do not conform to the scanning requirements set forth in Appendix E6. Number: 18 Created: 11 / 20 / 2006 [11/20/061 Directional ramps are required in the City of Fort Collins. Page 3 Topic: Site Plan Number: 53 Created: 11 / 28/ 2006 [11/28/06] The sidewalk along the east side of the entry drive from Conifer Street must be 10' wide. It currently is shown as 5' wide. Number: 54 Created: 11 / 28/ 2006 [11/28/06] There are overlapping utility facilities at the northeast corner of the site. Number: 55 Created: 11 / 28/ 2006 [11/28/06] Regarding bicycle parking on the site, with 30 vehicle parking spaces there must be at least 2 bicycle spaces (5% of vehicle parking, per the Land Use Code); however, considering the nature of the land use and clients using the facility, there should be additional bicycle parking provided. How many bicycles can the rack as shown accommodate? This should be indicated on the Site Plan. Number: 56 Created: 11 / 28 / 2006 [11/28/061 If the future 5,000 square foot building on Lot 2 were to develop as General Office use then there would be 2 parking spaces too many on that lot (3 spaces/ 1,000 square feet of building, per the Land Use Code). Number: 57 Created: 11 /28/2006 [11/28/06] What does EXT. mean in the fenced stor'g. areas? Number: 58 Created: 11 / 28 / 2006 [11/28/06] The handicapped ramps at the corner of Conifer Street and Blue Spruce Drive need to be "directional" ramps. Number: 59 Created: 11 / 28/ 2006 [11/28/06] The handicapped parking stall symbol as shown in the Legend is not being shown in the stalls on the plan. Number: 60 Created: 11 / 28/ 2006 [11/28/061 A request for a modification of the standard set forth in Section 3.5.3 of the Land Use Code, regarding the required "build -to" lines, must be submitted for review by staff and the Planning and Zoning Board. The Housing Services Day Center building does not satisfy this standard as it relates to Blue Spruce Drive. It is 17' from the street right-of-way. * Also, Neither the Housing Services Day Center building nor the future building on Lot 2 satisfy the standard set forth in Section 4.28(E)(2)(b) of the Land Use Code. Their setbacks from Conifer Street must be no more than 30' from the street right-of-way for at least.30% of the building face and they are shown as being 45' to 50' from the right -of - Page 2 ® STAFF PROJECT REVIEW City of Fort Collins Architecture West, LLC Date: 11/28/2006 c/o Heather Butler 4710 South College Avenue Fort Collins, CO 80525 Staff has reviewed your submittal for United Way Housing Services Day Center, PDP - Type 2 (Planning & Zoning Board review), and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 68 Created: 11 / 28/ 2006 [ 11 / 28 / 06] Rick Lee of the Building Department is forwarding a copy of the current Codes & Standards that his department will be enforcing. Also, a pre -submittal Code Review meeting is required prior to submitting for building permit. Topic: Landscape Plan Number: 63 Created: 11 /28/2006 [11/28/06] Per Section 3.2.1(E)(4)(a) of the Land Use Code, there must be 2 additional trees in the parking lot setback area along the west property line and 1 additional tree in the parking lot setback area along the north property line (see red -lined Landscape Plan). Number: 64 Created: 11 / 28/ 2006 [11/28/06] Per Section 3.2.1(E) (4) (b) of the Land Use Code, there must be additional shrub plantings, for screening purposes, in the setback areas to the parking lots along the west and north property lines (see red -lined Landscape Plan). Number: 65 Created: 11 / 28 / 2006 [ 11 / 28/ 061 Need additional shrub plantings along the south side of the south retaining wall for the detention pond along Conifer Street. Number: 66 Created: 11 / 28 / 2006 [11/28/06] There are 6 Juniper trees along the north property line that appear to be off of the property. If so, then a landscape easement will be required and must be obtained from the property owner to the north. Number: 69 Created: 11 / 28/ 2006 [11/28/06] A copy of comments from Tim Buchanan, the City Forester, is attached to this comment letter. Page 1