Loading...
HomeMy WebLinkAboutPECK APARTMENTS - PDP/FDP - FDP130031 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTA %4 0 LOCATION: PROJECT NO: COMPUTATIONS BY SUBMITTED BY: DATE: 100yr ORIFICE PLATE SIZING Detention Pond Outlet Sizing (100 yr event) 218 Laurel Street 348-0 l ppk North Star Design, Inc 7/23/2013 Submerged Orifice Outlet: release rate is described by the orifice equation, Qo = COAO sqrt( 2g(h-E,)) where Qo = orifice outflow (cfs) Co = orifice discharge coefficient g = gravitational acceleration = 32.2 ft/s Ao = effective area of the orifice (ft') E. = greater of geometric center elevation of the orifice or d/s HGL (ft) h = water surface elevation (ft) Qa = 0.08 cfs outlet pipe dia = D = 6.0 in Invert elev. = 4996.15 ft Eo = 4996.22 ft h = 4997.50 ft - 100 yr WSEL Co = 0.63 solve for effective area of orifice using the orifice equation Ao = 0.014 ftz 2.0 in orifice dia. = d = 1.60 in Check orifice discharge coefficient using Figure 5-21 (Hydraulic Engineering) d / D = 0.27 kinematic viscosity, u = 1.22E-05 ft2/s Reynolds no. = Red = 4Q/(pdu) = 6.26E+04 Ca = (K in figure) = 0.63 check Use d = 1.60 in Aa = 0.014 ft2 = 2.01 in' Q mar = 0.08 cfs Detention pond.xls N u Northstar Design, Inc 700 Automation Drive, Unit I Windsor CO, 80550 (970)686-6939 LOCATION: PROJECT NO: COMPUTATIONS BY SUBMITTED BY: DATE: Proposed Stage/Storage 218 Laurel Street 348-01 TDS North Star Design 7/23/2013 V = 1/3 d ( A + B + sgrt(A'B)) where V = volume between contours, ft3 d = depth between contours, It A = surface area of contour REQ. 100 YR DETENTION VOL. = 550 Cu.Ft. Stage (ft) Surface Area W) Incremental Storage (cu-ft) Total Storage (cu-ft) 96.15 0 97.00 537 152.150 152 97.50 1140 409.903 562 455 945 Detention pond.xls Stage -Storage t Northstar Design, Inc 700 Automation Drive, Unit I Windsor CO, 80550 (970) 686-6939 LOCATION: ITEM: COMPUTATIONS BY: SUBMITTED BY: DATE: WATER QUALITY POND OUTLET SIZING 218 Laurel Street Detention Pond PPK North Star Design, Inc 7/23/2013 From Urban Storm Drainage Criteria Manual, June 2001 (Referenced figures are attached in Appendix D) Use 40-hour brim -full volume drain time for extended detention basin Water Quality Capture Volume = WQCV = (required storage/12)'(tributary drainage area) MAJOR BASIN Trib. area (ac) % Imperv. Req. Storage (in. of runoff) WQCV (ac-ft) DWQ (ft) req. vol WQCV `1.2 (ac-ft) req. area/row (in 2/row) Pond 1 0.12 61.00 0.240 0.002 0.50 0.003 0.22 Required Storage = 1 " ( 0.91 " 1A3 - 1.19 " IA2 + 0.78 " 1 ) WQ outlet sizing From Figure 5, for 1/2 in. hole diameter Area of hole = 0.20 in # of columns = 1 Area provided/row = 0.20 in Area Required/row = 0.22 in Use 1 column of 112" diam holes Detention pond.xls WQCV-NOT USED 125 cf Fr 10 v -4 100 YEAR MINIMUM DETENTION VOLUME REQUIRED FAA METHOD LOCATION: 218 Laurel Street PROJECT NO: 348-01 COMPUTATIONS BY: ppk SUBMITTED BY: North Star Design, Inc DATE: 7/23/2013 Equations: Qo = CiA V; = T*CiA = T*Qo Vp -In*QPo*(60*T) S=V; -Vo Rainfall intensity from Larimer County Area I IDF Curve A trib. To pond = 0.12 acre C100 = 0.61 Developed C*A = 0.07 acre QPo = 0.08 cfs tc = 5.1 min Storm Duration, T (min) Rainfall Intensity, i (in/hr) QD (cfs) Vol. In V; (ft3) Outflow Adjustment Factor, m Vol. Out Vo (ft3) Storage S (ft3) Storage S (ac-ft) 5 9.95 0.7 197 1.00 25 171 0.004 10 7.72 0.6 305 0.76 38 267 0.006 20 5.60 0.4 443 0.63 63 379 0.009 30 4.52 0.3 536 0.59 88 448 0.010 40 3.74 0.3 591 0.56 1 114 478 0.011 50 3.23 0.2 638 0.55 139 500 0.011 60 2.86 0.2 678 0.54 164 514 0.012 70 2.62 0.2 725 0.54 189 536 0.012 80 2.38 0.2 753 0.53 214 538 0.012 90 2.22 0.2 790 0.53 240 550 0.013 100 2.05 0.2 810 0.53 265 545 0.013 110 1.93 0.1 839 0.52 1 290 549 0.013 120 1.80 0.1 854 0.52 315 539 0.012 130 1.60 0.1 822 0.52 340 482 0.011 140 1.40 0.1 775 0.52 366 409 0.009 150 1.20 0.1 712 0.52 391 321 0.007 160 1.15 0.1 727 0.52 416 311 0.007 170 1.10 0.1 739 0.52 441 298 0.007 180 1.05 0.1 747 0.51 466 281 0.006 Required Storage Volume: 550 ft 3 0.013 acre-ft APPENDIX C DETENTION POND CALCULATIONS C North Star Design, Inc. 700 Automation Drive, Unit I Windsor, CO 80550 RATIONAL METHOD PEAK RUNOFF (100-YEAR) LOCATION: 218 Laurel PROJECT NO: 348-01 COMPUTATIONS BY: PPK DATE: 7/23/2013 DIRECT RUNOFF TOTAL Inlet Capacity REMARKS DESIGN POINT SUBBASIN ID A (ac) Cino t, (min) i (in/hr) O100 (cfs) Oiuo Total (cfs) (cfs) EX 1 EX 1 0.15 0.58 5.9 9.55 0.85 0.9 DEV 1 DEV 1 0.12 0.61 5.1 9.91 0.76 0.8 DEV 2 DEV 2 0.03 0.73 5.0 9.95 0.23 0.2 Q=CiA Q = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from OF curve A = drainage area (acres) Flow site.xls 0100 s North Star Design, Inc. 700 Automation Drive, Unit I Windsor, CO 80550 RATIONAL METHOD PEAK RUNOFF (10-YEAR) LOCATION: 218 Laurel PROJECT NO: 348-01 COMPUTATIONS BY: PPK DATE: 7/23/2013 DIRECT RUNOFF TOTAL Inlet Capacity REMARKS DESIGN POINT SUBBASIN ID A (ac) Coo t� (min) i (in/hr) Qio (cfs) Quo Total (cfs) (cfs) EX 1 EX 1 0.15 0.42 5.9 4.67 0.30 0.3 DEV 1 DEV 1 0.12 0.48 5.1 4.85 0.29 0.3 DEV 2 DEV 2 0.03 0.64 5.0 4.87 0.10 0.1 Q=CiA Q = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from OF curve A = drainage area (acres) Flow site.xls Q 10 North Star Design, Inc. 700 Automation Drive, Unit I Windsor. CO 80550 RATIONAL METHOD PEAK RUNOFF (2-YEAR) LOCATION: 218 Laurel PROJECT NO: 348-01 COMPUTATIONS BY: PPK DATE: 7/23/2013 DIRECT RUNOFF TOTAL Inlet Capacity REMARKS DESIGN POINT SUBBASIN ID A (ac) C2 tc (min) i (in/hr) Qz (cfs) Qz Total (cfs) (CIS) EX 1 EX 1 0.15 0.28 5.9 2.73 0.12 0.1 to alley DEV 1 DEV 1 0.12 0.37 5.1 2.84 0.13 0.1 to Linden DEV 2 DEV 2 0.03 0.57 5.0 2.85 - 0.05 1 0.1 Ito alley Q=CiA Q = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from IDF curve A = drainage area (acres) Flow site.xls Q2 North Star Design, Inc. 700 Automation Drive, Unit I Windsor, CO 80550 TIME OF CONCENTRATION LOCATION: 218 Laurel PROJECT NO: 348-01 COMPUTATIONS BY: PPK DATE, 7/23/2013 SUB -BASIN DATA INITIAL OVERLAND TIME (t;) TRAVEL TIME I GUTTER OR CHANNEL FLOW (Q) t, CHECK (URBANIZED BASIN) FINAL I� REMARKS DESIGN POINT SUBBASIN ID (1) Area (ac) (2) Cs (3) Length (ft) (4) Slope (ft/ft) (5) t, (min) (6) Length (ft) (7) Slope (ft/ft) (8) Chan. Type C, Vel. (fNs) (9) I, (min) (10) t� = ti+❑ (11) Total L (ft) (12) t�= (1/180)+10 (min) (13) (min) (14) EX 1 EX 1 0.15 0.35 23 0.020 5.2 68 0.007 F 20 1.7 0.7 5.9 91 10.5 5.9 DEV 1 DEV 1 0.12 0.42 10 0.040 2.5 164 0.005 E 15 1.1 2.6 5.1 174 11.0 5.1 DEV 2 DEV 2 0.03 0.60 18 0.050 2.3 84 0.007 F 20 1.7 0.8 3.1 102 1 10.6 5.0 EQUATIONS: t�=ti+I, I, = (0.395 (1.1 - CS ) Lo.S ] / S 1/3 tt = L/V V = C `So.s final t, = minimum of D, + tt and urbanized basin check minimum t, = 5 minutes Channel Type C„ A Heavy Meadow 2.5 B Tillage/Field 5.0 C Short Pasture/ Lawn 7.0 D Bare Ground 10.0 E Grassed Waterway 15.0 F Paved 20.0 Flow site.xls T005 North Star Design, Inc. 700 Automation Drive, Unit I Windsor, CO 80550 RUNOFF COEFFICIENTS & % IMPERVIOUS LOCATION: 218 Laurel PROJECT NO: 348-01 COMPUTATIONS BY: PPK DATE: 7/23/2013 Recommended % Impervious from Urban Storm Drainage Criteria Manual Impervious Roofs: 90% Streets and Parking (Asphalt) 100% Concrete Drives and Walks 90% Packed Gravel: 40% Landscaped Areas (Clayey soil, 0-1 % SUBBASIN ID TOTAL AREA (ac.) TOTAL AREA (sq.ft) ROOF AREA (sQ.ft) ASPHALT AREA (s4.ft) CONCRETE AREA (sg.ft) GRAVEL AREA (sQ.ft) LANDSCAPE AREA (sq.ft) % Impervious RUNOFF COEFF. Ci RUNOFF COEFF. Cs RUNOFF COEFF. CID RUNOFF COEFF. Goo EX 1 0.15 6,653 1,573 403 786 340 3,551 40% 0.28 0.35 0.42 0.58 DEV 1 0.12 5,425 3,240 0 35 0 2,150 54% 0.37 0.42 0.48 0.61 DEV 2 0.03 1,398 0 0 1,210 0 188 78°/ 0.57 0.60 0.64 0.73 Flow site.xis Cval APPENDIX B HYDROLOGIC COMPUTATIONS .�� 11111 -- -- ■II� iC all-� Ell lillli==■illl:!■�Il:iill� ��='illlllll@ ice= Pup ;F-1 ff- FIT I u -- �1 - n9w'i I�PROJECT-II LOCTI AON - i Ir? i EAST ELIZABETH STREET wriEAST PITKIN u VICINITY MAP APPENDIX A VICINITY MAP ►r] 7. REFERENCES City of Fort Collins, "Storm Drainage Criteria Manual", (SDCM), dated March, 1986. 2. Urban Drainage and Flood Control District, "Urban Storm Drainage Criteria Manual", Volumes 1 and 2, dated March, 1969, and Volume 3 dated September, 1992. 13 IX R I, _ 9�4) II �I 10 s 0 10 20 SCALES 1' 10' EOP ¢� 090 I I III ati TDID I PROPOSED LANDSCAPE WALL 1 W-9).5 BW-9).0 -- - - - -- - "ail ���� T I .I � 1 I I. w I � I I'-IXrt I 1' I � I I I 1 I D y I I I SIR I : I I. I W J y� 15 I I' I I I �/ ' /W.6) � pi51 I I� I I- I RX k -IXR TOP OP BERM-499).Sdo q��ryryEO� TOP OF BERM-4997.5 ---- - - --- - h - ,-------? , ------ - -_ - -- - - I So1.ww PROPOSED ,• WIDE PROPOSED lANDSLAPE METAL 9"" CULVERT. ; WAIL W/1.6" Dim ORENwG _ sAWESAm T WALK As FEESSARt M WSTALL MEC CUT T WOE OPENING IN E10511NG "o HEAD WEST LAUREL STREET GRADING PLAN SF I I I DETENTION POND I I I •, I i T 12 0.4 DETENTION POND HWEL-41197.51 J� WEST LAUREL STREET CALL UTLl7Y NOTIFICATION CENTER OF COLORADO 1-800-922.1987 (811) C 2-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG. GRADE. OR EXCAVATE FOR TIE MARKING OF UNDERGROUND MEMBER UTILITIES. THIS SECTION OF SILT FENCE To BE REYOMED PRIOR TO GONCRETE INSTALLATION. ALL OTHER SILT FENCE SHALL REMI FDA THE DURATION OF THE CONSTRUCTION I LEGEND I iT FT ISNED ROOD PROPERTY BOUNDARY FC FINISHED CRADF — RI.1-OF-WAY iLO ADJACENT PROPERTY LINE 1 NP NIGH ON, O - EASEMENT LINE 1 LP LOW POMi '-m _.910- - - - - - EXISTING CONTOURS 1 EOA EDGE OF ASPHALT 491, PROPOSED CONTOURS RE EDGE OF CONCRETE PROPOSED ROWI TOA TOP OF ASPHALT PROPOSED 2 CONCRETE PAN TCC TOP OF CONCRETE _ _ _ _ _ _ _ _ _ _ = E JSTNG DRAINAGE PIPE I • TOW TOP OF WALK gIPRAP 1 EN EXISTING A. J I DESIGN PONT J - Q .I BASH CRITERIA I _ 0.26 0.9 5 m RUNOFF COFFFlCIENT AREA IN ACRES ^ ROW DIRECTION D 60L1 R 9TI IF a¢R 6¢ BASIN BWNDART I 1 O—SF—SF— SILT FENCE - I 1 ® _ VEHICLE mACKwc PAD CW CONCRETE WASNOUT AREA II I! i RS� ROCK SOLI( STRAW WATRE r� I I! I I. 5' WE UD WALE SEE DETAIL SNIEE-E 5 _ . . - .. W615CA➢E WALL WTH T.o- 4 DIAM OPENING FOR DEIENTpN RELEASE , DRAINAGE & EROSION CONTROL PLAN w 0 O t „�pOp /REd�p2 O O:'LNKEp a �R 12(yC•"Os'p�J�6 �q2 Q 2PC�• r W W I.:L Z �J d W z OfO O� � o z Q O J 0 fJ z H Qo W 00 fi LLJ Go City of Fort Collins. Colorado N UTILITY PLAN APPROVAL APPROVED: City Enpnm D.I. SHEET CHECKED BY: wotw h wmb.otw oUitr oete CHECKED BY: s4 tm.�.Ob. uuny and CHECKED BY: Pw4. h flmw\im Date 4 OF 6 CHECKED BY: huNc E.9—. G.t. CHECKED BY: Job No. 348-0I D.t. of any pollutants to downstream waters. 7) Inspection & Maintenance: It is required that routine site inspections are performed to effectively address maintenance and repair of Best Management Practices (BMP's). The site inspections are to performed by the contractor or an inspector designated by the administrator at a minimum of once every fourteen (14) calendar days on active construction sites and after any significant storm event (an event causing runoff). As part of the site inspections the inspector is required to keep documentation of all inspections and BMP maintenance, including an updated Site Map indicating new BMP's or the removal of BMP's since the previous inspection. Any maintenance, repair, or necessary installation of BMP's that are noted during the inspection must be completed within seven (7) calendar days from the date of the inspection. 6. CONCLUSIONS 6.1 Compliance with Standards All computations that have been completed within this report are in compliance with the City of Fort Collins Storm Drainage Design Criteria Manual and the Old Town Master Drainage Plan. 6.2 Drainage Concept The proposed drainage concepts presented in this report and on the construction plans adequately provide for conveyance of runoff to the detention areas. Conveyance elements have been designed to pass required flows and to minimize future maintenance. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit would be required. 12 minimize the transport of sediment (mud) by runoff or vehicles tracking onto the paved surface. Any mud tracked to public roads shall be removed on a daily basis and after any significant storm that causes sediment to be transported. It is unlawful to track sediment/mud onto public streets and may be enforced by the City of Fort Collins or by the State of Colorado. 5) Waste Management and Disposal: Portable toilets will be anchored & periodically maintained by waste management company. Dumpsters on site will be covered & periodically emptied by waste management company. Concrete waste will be allowed to harden and then will be removed from site. No washing activities will occur on site. Location of the concrete washout will be determined by the contractor. The washout will be sufficiently deep to accommodate all anticipated concrete truck wash water. Waste concrete will be allowed to harden and be removed from site periodically as the washout reaches 50% of its capacity. Truck wash water will not be allowed to reach the curb & gutter or any other water course. 6) Groundwater and Stormwater Dewatering: No groundwater encountered during soils exploration therefore not anticipated to be an issue. If groundwater is encountered a groundwater discharge permit shall be obtained and a detailed report shall be completed describing the location and the route of where pumped groundwater will be conveyed and the measures taken to prevent the transport 2 Materials Handling and S ill Prevention: Materials Handling & Spill Approximate location on site Applicable to this Prevention BMP Project Portable toilets, anchored & Contractor to determine X located away from drainages Fuel storage located in bulk tanks with secondary containment & spill kit Mobile fueling performed at least 200 feet away from drainages & Contractor to detennine X fully attended Fertilizers, form oil, solvents, cleaners, detergent stored in 55 gal Contractor to determine X or smaller containers, kept in storage units Dumpsters containing used chemicals containers & liquid Contractor to determine X wastes kept covered Equipment cleaning (on site) uses no detergents & flows to onsite retention basin In case of a release of fuel or other chemicals, absorbent booms or earthen berms will be immediately Location of spill X constructed to contain the spill & prevent runoff to adjacent surface waters MSDS sheets for onsite chemicals will be kept at the construction Contractor to determine X trailer to facilitate spill response & cleanup 3) Dedicated Asphalt or Concrete Batch Plant: Not proposed with this development. 4) Vehicle Tracking Pad: Vehicle tracking control pad shall be installed wherever construction vehicle access routes intersect paved public roads. Vehicle tracking control pads shall be installed to E SEDIMENT/EROSION CONTROL BEST MANAGEMENT PRACTICES (BMPs) COST OPINION SPREADSHEET 218 West Laurel Street Item No. BMP ID Unit Installation Unit Cost Maintenance as % of Installation Installation & Maintenance Unit Cost Quantity Cost 1 Check Dam CDR LF 25% $0.00 $0.00 2 Check Dam (Reinforced) CDR LF 25% $0.00 $0.00 3 Concrete Washout Area CWA EA $1,200.00 200% $3,600.00 1 $3,600.00 4 Construction Fence CF LF 25% $0.00 $0.00 5 Construction Markers CM LF 50% $0.00 $0.00 6 Culvert Inlet Filter CIF LF 25% $0.00 $0.00 7 Dewatering DW EA 50% $0.00 $0.00 8 Diversion Ditch (Unlined) DD LF 25% $0.00 $0.00 9 Diversion Ditch (ECM or plastic) DD LF 10% $0.00 $0.00 10 Sediment/Erosion Control Matting ECM SY 25% $0.00 $0.00 11 Inlet Protection IP LF 50% $0.00 $0.00 12 Reinforced Rock Berm RRB LF 25% $0.00 $0.00 13 Sediment Basin (1) SB LF 25% $0.00 $0.00 14 Sediment Control Log (Wattle) SCL LF $4.60 25% $5.75 0 $0.00 15 Seeding and Mulching SM AC 50% $0.00 $0.00 16 Silt Fence SF LF $3.00 75% $5.25 370 $1,942.50 17 Rock Sock RS LF $10.00 10% $11.00 30 $330.00 18 Stabilized Staging Area SSA SY 50% $0.00 $0.00 19 Surface Roughening SR AC 25% $0.00 $0.00 20 Temporary Stream Crossing TSC EA 25% $0.00 $0.00 21 Topsoil (6-inch Lift) TSL AC $2,500.00 25% $3,125.00 0.06 $187.50 22 lVehicleTrackin Control(2) VTC EA $1,500.00 100% $3,000.00 1 $3,000.00 Contractor Added BMP(s) (3) 23 % $0.00 24 % $0.00 25 % $0.00 26 % $0.00 27 % $0.00 P8 % $0.00 SUBTOTAL COST $9,060.00 CONTINGENCY 15% $1,359.00 TOTAL COST lot $10,419.00 erosion control associated with each phase in order to comply with the SWM Plan and Permit that is obtained by the contractor (or owner) for the site. Phase 1 — Mobilization Install silt fence, Install rock socks, set dumpster. Phase 2 — Clear site, Overlot Grading Clear existing house, concrete and treess. Cut and fill on site to achieve subgrade elevations Phase 3 - Utilities Excavate and install for water service, fire line and sewer service modification, excavate and install dry utilities Phase 4 — Install Concrete Foundation Establish temporary concrete washout area, cut for building foundation, place concrete foundation. Phase 5 — Concrete Site Paving Remove silt fence in pavement area, Install sub base, install Concrete pavement. Remove concrete wash out. Phase 6 — Building construction Complete vertical building construction Phase 7 — Landscape installation Final shaping of detention pond, install LID Swale, final shape planting areas, Install irrigation system, Install soil amendments, Landscape plant installation, Install mulch ground cover Phase 8 — Final Stabilization Final stabilization is complete when constructed improvements are in place, Inspect completed construction for possible sources of erosion and amend the plan as required to trap sediments. E No area shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. Temporary& Permanent non-structural BMP's: Non -Structural BMP Approximate location on site Applicable to this Project' Surface roughening Entire site X Soil stockpile height limit (less than 10') Perimeter vegetative buffer West boundary of site X Minimization of site disturbance Mulch Seed & mulch stockpiles after 30 days Stockpile toe protection (silt fence, wattles or ditch) Preservation & protection of West boundary of site X existing vegetation & trees Good site housekeeping (routine Entire Site X cleanup of trash & constr debris) Heavy equip staged on site, properly maintained & inspected Staging area X daily (no onsite maintenance) 5.5 BMP Implementation 1) Phased BMP Implementation BMP's are expected to change as the construction progresses and it is the responsibility of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction sequence. All BMP's shall be inspected and repaired or replaced as required to satisfy the conditions of the Stormwater Discharge Permit. All BMP's must be maintained and repaired as needed to assure continued performance of their intended function. The following phase depictions and erosion controls are suggestions to the contractor only and are in no way intended to dictate construction phasing or control of the work on site. The contractor shall be responsible to control construction phasing and provide adequate N All BMP's shall be installed per the details shown on the construction plan set. Temporary & Permanent Structural BMP's: Structural BMP Approximate location on site Applicable t this Project Silt Fence Site perimeter, refer to site map X Straw bale dams Rock Socks At proposed sidewalk culverts, refer to site map X Earthen diversion darns Vegetated swales Sediment trap/pond Pipe slope drains Geogrid Inlet/outlet protection Culverts Riprap Erosion control unats Inlet protection Non -Structural Practices for Erosion and Sediment Control: Soils exposed during the earthwork phase and landscape prep phase shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control is installed. No large amount of soils (in excess of 15 yards) will be allowed to be stock piled on site. Overburden from the utility pipe trenching will be piled adjacent to trenches upstream of sediment controls and will be replaced in the trenches within 72 hours. Excess excavated materials from the demolition and grading phases of the project that cannot be reused on site will be exported as it is excavated. This includes any asphalt pavement from the existing site that is to be removed. A vehicle tracking pad will be installed at a location most beneficial to the site construction as determined by the contractor. Vehicles will not be permitted in the excavated area if soil is muddy. Gravel sub base will be placed and compacted in the areas indicated for pavement following excavation. In the current pre construction state the site enables tracking of silt onto the adjacent streets during wet conditions. During construction activities the street will be monitored for foreign debris tracked out of the site and mechanical sweeping and clean up will be performed as needed. 7 m 5.3 Identification and location of all potential pollution sources Potential Pollutant Source Activity Potential Pollutant'Generated Applicable to this project Disturbed Areas Sediment X Soil stockpiles Sediment X Travel to adjacent public streets Tracked sediment X Contaminated soils Sediment, chemicals Loading and unloading chemicals Chemicals Outdoor storage of chemicals Chemicals On site equipment maintenance Oil, grease On site equipment fueling Diesel, gasoline X Dust generating activities Particulates, sediment X Use of fertilizer, pesticides, herbicides Fertilizer, pesticides Use of detergents, solvents, oils Detergents, solvents, oil X Waste dumpsters, waste piles Chemicals X Concrete washout Concrete, sediment X On site equipment washing Detergents, oil On site asphalt batch plant Asphaltic cement, sediment On site concrete batch plant Cement, sediment Portable toilets Domestic sewage X 5.4 Best Management Practices (BMP's) for Stormwater Pollution Prevention Structural Practices for Erosion and Sediment Control Structural practices for the site will consist mainly of silt fence and rock sock filters and are described in detail in the following paragraphs. These BMP's are expected to change as the construction progresses and it is the responsibility of the contractor to ensure appropriate BMP's are in place and/or removed at the appropriate time in the construction sequence. All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their intended function. Silt fence and rock sock filters shall be in place prior to commencement of construction activities. During clearing and grubbing necessary for silt fence installation, all cleared material shall be placed on the uphill side so that if erosion occurs from the cleared material, the sediment will be trapped and not transported downstream. Rock socks shall be implemented in the existing curb line as shown on the Drainage & Erosion Control Plan. 6 The locations of the rock socks will be in the areas of concentrated flow such as the existing curb and the proposed sidewalk culverts. The site may also utilize a vehicle tracking control pad to minimize sediment from being tracked onto adjacent pavements. Sediment that is tracked will be removed and placed within the site or permanently disposed of offsite. A concrete washout will be used on site during the concrete placement. All hardened concrete will be disposed of offsite. These BMP's have not been located on the site map due to the fact that the site is very small and these BMP's will need to be placed by the contractor in locations that are most beneficial and will minimize disruption of adjacent traffic. Permanent erosion control consists of covering the soils with a building, concrete walks, concrete drives and sod. No soil will be left exposed to erosion after the construction is complete. Refer to the landscape plan for areas of and instructions for placement of sod and soil amendments required prior to placement of sod. Refer to section 5.5 for the timing of the construction phases and the sequential installation of all BMP phasing for this site. Refer to the end of Section 5.4 for the Erosion Control Surety calculations. 5.2 SWMP contact information Permit holder: Name: Address: Phone Number: Email Address: Appointed agent: Name: Address: Phone Number: Email Address: f; I We are requesting a variance from the criteria that requires that 25% of the site pavements be impervious. This site has approximately 1200 square feet of concrete proposed on site which is entirely within Basin 1, a majority of which is in the driveways with a small portion being the sidewalk and the trash enclosure. Of the 1200 square feet, approximately 900 square feet can be driven on and 25% of this area would equate to 225 square feet of pervious pavement. We believe this amount of pervious pavement would have little to no impact on the quality of the runoff from this site. 4.3 Drainage Summary All runoff from this site and the adjacent sites will be safely conveyed via surface flow to the detention pond. The site will generally conform to the Old Town Master Drainage plan which this site is included in. The City of Fort Collins will be responsible for maintenance of the existing storm drainage facilities located within the right-of-way. The drainage facilities located outside of the right of way (including the detention pond) will be maintained by the property owner. 5. STORMWATER MANAGEMENT CONTROLS 5.1 Written Analysis The soils on this site are classified by the USGS Soil Survey as Fort Collins Loam and are classified in the hydrologic group B. The rainfall and wind erodibility is deemed to be moderate. The Group B soils are Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. The site is surrounded by developed sites including streets and paved areas. The construction shall utilize silt fence around the perimeter to control sediment transport from rainfall and from wind. The silt fence that is located in the proposed pavement areas will be removed prior to placing new pavement. Rock socks will be utilized in the existing curb to capture sediments that are not fully contained by the silt fence placement. 4 4. DRAINAGE FACILITY DESIGN 4.1 General Concept The runoff from this site will be collected in a grassed swale along the west property line and be conveyed to the detention pond on the south portion of the site. A small amount of runoff will be allowed to discharge directly to the existing alley on the east property line. A small amount of flow from the property on the west is anticipated to enter the site and will be conveyed to the detention area. The offsite flows will not be detained and will flow over the detention pond berm. 4.2 Specific Flow Routing A summary of the drainage patterns within each basin is provided in the following paragraphs. Basin 1 encompasses the majority of the proposed development including the building, front porch, front walk and the landscaping on the north, west and south sides of the site. A majority of the runoff flows to the grassed swale on the west property line which will convey the flows south to the proposed detention pond. This detention pond will have a very small release rate (0.08 cfs) which allows for a 1.6" diameter orifice on the outlet. The water quality extended detention is incorporated into the detention volume. In the east most portion of the pond, an LID swale is being incorporated into the detention pond also. The pond will have 0.5' of freeboard to the building finished grade and 1.25' of freeboard to the building finished floor. The pond will have a spillway all along the existing sidewalk on the north side of West Laurel Street. Basins 2 includes the proposed driveways on the east side of the site. The runoff from this basin will flow east directly into the alley and be conveyed to the south and into West Laurel Street or north eventually reaching West Myrtle Street. This flow path is the historic flow path for the runoff from this site. Because the runoff from this Basin exceeds the 2 year historic runoff from the site, the detention release allowed from Basin I has been reduced. 3 V. 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations This report was prepared to meet or exceed the "City of Fort Collins Storm Drainage Design Criteria Manual" specifications. Where applicable, the criteria established in the "Urban Storm Drainage Criteria Manual" (UDFCD), developed by the Denver Regional Council of Governments, has been used. 3.2 Development Criteria Reference and Constraints The runoff from this site has been routed to conform to the Old Town Master Drainage plan and the existing conditions on site. The Old Town Basin is restricted to a 2 year historic release rate with redevelopment. Because of the existing development on all four sides to this site, the east portion of the development (the driveways) will release directly onto the alley without detention. The runoff from the remainder of the site, including the entire proposed building, will be directed to a swale on the west property line that conveys the runoff to the proposed detention pond. The release rate for the detention pond has been reduced from the 2 year historic release rate in order to partially compensate for the free release runoff from the driveways. The detention pond will release directly into West Laurel via a sidewalk culvert and a curb opening. 3.3 Hydrologic Criteria Runoff coefficients calculations were prepared for the 2 and 10-year minor and 100-year major storm frequency utilizing the rational method. Detention is proposed on site (with incorporated water quality volume) with a release rate below the 2 year historic runoff rate. 3.4 Hydraulic Criteria No subsurface drainage conveyances are proposed with this development; therefore no hydraulic calculations were completed with this design. 2 V 4� 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location The site is located on the East '/z of the East % of Lots 12 and 13, Block 106 Harrison Addition in Section 5, Township 6 North, Range 68 West of the Sixth Principal Meridian, in the City of Fort Collins, Larimer County, Colorado. The address of the existing site is 218 West Laurel Street. See the location map in Appendix A. The project is located on the north side of West Laurel Street between South Mason Street and South Howes Street. The project is bounded on the north and west by existing (�S on the east by Rainbow Cafe and the alley and on the south by Laurel Street l J and CSU campus. V ut Gt 1 E- 1.2 Description of Property The entire site consists of approximately 0.15 acres of land. The land is currently developed with an existing house and concrete walks and drives. The site currently drains to the alley on the east and then to the north and south. Slopes on site range from approximately 0.5% to 1%. This project will include the development of a six-plex residential building, driveways and landscape area. The site will be reconfigured so that a majority of the runoff will be directed to the west propert line ine and south into the proposed detention and water quality 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description The proposed development lies within the Old Town Drainage Basin. 2.2 Sub -basin Description This site has not been included in any known previous drainage study. TABLE OF CONTENTS TABLEOF CONTENTS............................................................................................................... iii GENERAL LOCATION AND DESCRIPTION 1.1 Location...................................................................................................................1 1.2 Description of Property............................................................................................I 2. DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description..........................................................................................1 2.2 Sub -Basin Description.............................................................................................I 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations..............................................................................................................2 3.2 Development Criteria Reference and Constraints...................................................2 3.3 Hydrologic Criteria..................................................................................................2 3.4 Hydraulic Criteria....................................................................................................2 4. DRAINAGE FACILITY DESIGN 4.1 General Concept......................................................................................................3 4.2 Specific Flow Routing.............................................................................................3 4.3 Drainage Summary ..................................................................................................4 5. STORMWATER MANAGEMENT CONTROLS 5.1 Written Analysis.....................................................................................................4 5.2 SWMP Contact Information...................................................................................5 5.3 Identification and location of all potential pollution sources..................................6 5.4 Best Management Practices (BMP's) for Stormwater Pollution Prevention ........... 6 5.5 BMP Implementation..............................................................................................8 6. CONCLUSIONS 6.1 Compliance with Standards..................................................................................12 6.2 Drainage Concept..................................................................................................12 7. REFERENCES..................................................................................................................13 APPENDICES A Vicinity Map B Hydrologic Computations C Detention Pond Calculations Y 4- North Star design 700 Automation Drive, Unit I Windsor, CO 80550 Phone:970-686-6939 Fax:970-686-1188 July 23, 2013 Glen Schlueter City of Fort Collins Stormwater 700 Wood Street Fort Collins, CO 80522-0580 RE: Final Drainage and Erosion Control Study for 218 West Laurel Street Dear Glen, I am pleased to submit for your review and approval, this Final Drainage and Erosion Control Study for 2118 West Laurel Street. I certify that this report for the drainage design was prepared in accordance with the Old Town Master Plan and the criteria in the City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, Patricia Kroetch, P.E. ii 9 4.- FINAL DRAINAGE AND EROSION CONTROLSTUDY 218 WEST LAUREL STREET Prepared for: Dana Lockwood Lockwood Architects 415 East Pitkin Fort Collins, CO 80524 Prepared by: North Star Design, Inc. 700 Automation Drive, Unit I Windsor, Colorado 80550. (970)686-6939 July 23, 2013 Job Number 348-01