HomeMy WebLinkAboutCSU SOUTH FOOTHILLS ANNEXATION & ZONING, STRUCTURE PLAN AMENDMENT - 15-07 - CORRESPONDENCE -Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 6 Created: 6/27/2007 [6/27/07] PFA's main concern along the foothills is that an adequate water supply can be provided. Water pressure historically is very low in this area; many commercial buildings require fire pumps to be able to meet minimum water -flow needs for automatic fire -sprinkler systems, because hydraulic calculations show the unassisted pressure and flow do not meet minimum requirements. The minimum flow and spacing requirements for fire hydrants for commercial buildings is 1,500 gpm at 20 psi residual pressure; no building shall be farther than 300 feet to a fire hydrant, with hydrants located on 600-foot center. Department: Stormwater-Water-Wastewater Topic: Stormwater Number: 3 [6/25/07] No Comments. Department: Stormwater-Water-Wastewater Topic: WaterlWW Number: 5 [6/26/07] No comments. Department: Zoning Topic: Zoning Number: 2 [6/13/07] No comments Issue Contact: Basil Hamdan Created: 6/25/2007 Issue Contact: Roger Buffington Created: 6/26/2007 Issue Contact: Jenny Nuckols Created: 6/13/2007 Larimer County Planning Department Issue Contact: Dan Kunis [6/20/07] It is Larimer County Engineering's expectation that as part of the annexation, the entire right of way of Larimer County roads adjacent to the property will also be annexed. If the annexation is approved and the project moves forward, Larimer County Engineering would recommend that a traffic impact study and drainage report be required. County Engineering would appreciate the opportunity to review these reports as to the impacts the development will have on the transportation and drainage facilities in the unincorporated portions of the County. County Engineering requests that any County transportation or drainage facilities that are not adequate to handle the additional development be made adequate. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6376. Sincerely, Timothy Wilder City Planner Page 2 aSTAFF PROJECT REVIEW City of Fort Collins Date: 07/06/2007 Brian J. Chase - Director of Facilities Colorado State University Fort Collins, CO 80523 Staff has reviewed your submittal for CSU SOUTH FOOTHILLS CAMPUS ANNEXATION & ZONING & STRUCTURE PLAN AMENDMENT, and we offer the following comments: ISSUES: Department: City Planning Issue Contact: Timothy Wilder Topic: General Number: 8 Created: 7/6/2007 [7/6/07] City staff is currently working on a proposed Intergovernmental Agreement (IGA) between the City and CSU that addresses various issues reviewed at the monthly City-CSU coordination meetings. The IGA will need to be finalized before the Initiating Resolution is reviewed by Council on August 21. The City Manager's Office will contact CSU Administration within the next two weeks to discuss the IGA further. In addition, changes will be requested of the Petition for Annexation in order to provide consistency with the proposed IGA. Number: 9 Created: 7/6/2007 [7/6/07] In addition to review of this Annexation Petition, the City will be concurrently proposing an expansion to its Growth Management Area to include the entire Foothills Campus as identified in City Plan, the City's Comprehensive Plan. Department: Current Planning Topic: Stormwater Number: 4 [6/26/07] No comments. Issue Contact: Dana Leavitt Created: 6/26/2007 Department: Engineering Issue Contact: Sheri Langenberger Topic: General Number: 7 Created: 6/28/2007 [6/28/07] Comments from Technical Services - 1) Boundary and legal close 2) Reception number for Minatta annexation is different in the legal and on the the plat. 3) Show row for CR 441 (Rampart Rd). What is the width? How was it dedicated? What is the geometry? Is it both a County road and Rampart Road? Department: Light & Power Issue Contact: Ellen Switzer Topic: Electric Number: 1 Created: 6/12/2007 [6/12/07] This annexation is within Xcel Energy electric service territory. No electric service rights fees will apply after the City assumes electric service to the area. Page 1