HomeMy WebLinkAbout226 PETERSON STREET ACCESSORY BUILDING W/ HABITABLE SPACE - PDP - 39-06 - CORRESPONDENCE - (9)Responses to Comments of 1/12/07 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I Department: Stormwater-Water-Wastewaterlssue Contact: Wes Lamarque Topic: Stormwater Number. 12 Created: 11812007 (1/8/07] Please submit a grading plan for the rear half of the lot. This is needed due to the fact more than 350 sf of impervious area is being added. This can be done on the site plan. Response: The grading of the driveway slab is shown on the site plan as sloping @ a 2% grade toward the alley. The north, west and south side yards are level with less than 6 inch grade change over the area of proposed work. Therefore, no grading contours are shown. Site grading will be performed such that run off from the north, west and south sides of the proposed structure will be contained on the site property and not impact adjacent properties. Department: Zoning Issue Contact: Jenny Nuckols Topic: ZONING Number- 1 Created. 12/28/2006 [12/28/06] Please see comment #11 from Shelby regarding the 1 1/2 story limitation. Response: Comment noted, see response to comment #11. Number.• 14 Created: 1/9/2007 [1/9/07] Page,1 - Proposed Accessory Building calculations are incorrect. The main floor of the building has to count towards the square footage and to be considered accessible based on building code requirements must have a minimum ceiling of 7'6". The main floor comprises 600 sq ft which is maximum square footage for an accessory building with habitable space. The second floor or half floor, ceiling height cannot exceed 7'5" in order not to be counted towards the total square footage which again, cannot exceed 600 square feet total. Response: The revised plan has eliminated the upper half story. The total floor area is now 600 sq. ft. Responses to Comments of 1/12/07 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I Response: The electrical power to the accessory building will come.from the existing house panel as indicated on Sheet 1 of 2 (Site Plan). Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 18 Created: 1110/2007 [1/10/07] ACCESS: To be considered within fire department access, the front door of the proposed structure is required to be no more than 150 feet (as a hose would lay) from the Peterson Street curb. Because the building is out of access, an approved, automatic fire -sprinkler system is required (NFPA 13R). Response: Front door is 169 feet from the Peterson Street Curb. The north side of the accessory building is within 150 feet of the Olive Street curb via the rear alley. The structure is a garage with no dwelling space. This structure is comparable in type and location to other structures on this block and in this neighborhood with no sprinkler systems. Number. 19 Created: 111012007 [1/10/07] ADDRESSING: The approved address for the proposed structure (226 B) shall be clearly mounted on the front side of the building, in minimum 6-inch numerals/letters, with a color that contrasts with that of the structure siding. Response: The proposed structure is a garage (accessory building) and does not need a separate address. Department: Transportation Planning Issue Contact: David Averill Topic: General Number. 15 Created: 111012007 [1/10/07] What type of walkway is proposed for pedestrian access the public sidewalk on Peterson St. ? Response: There is no needed or proposed pedestrian access to the public sidewalk on Peterson St. Department: Stormwater-Water-Wastewaterlssue Contact: Roger Buffington Topic: General Number.' 17 Created: 111012007 [1/10/07] If this building is not a dwelling unit now or in the future, water and sewer service may be extended from the house to the accessory building. If, on 'the other had, this will ever be a dwelling unit, separate water/sewer services will be required, and the associated development fees will be due. Response: This building is not now nor will ever be a dwelling unit. Responses to Comments of 1/12/07 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I Number. 22 Created. 1/12/2007 [11121071 See Appendix E6 of the Larimer County Urban Area Street Standards (LCUASS) for scanning requirements. Response: Appendix E6 has been reviewed. Please advise if, based on your experience, the revised plans will scan satisfactorily and what changes are recommended. Number- 23 Created: 1/12/2007 [1/12/071 Please add this note to the cover sheet: "General Construction Notes #1 through 18, 20 through 39, and 42 through 46 as listed in Appendix E-1 of the Larimer County Urban Area Street Standards (LCUASS) shall apply and be followed for this project." "The Construction Notes under subsection Street Improvement Notes and Traffic Signing, and Pavement Marking Construction Notes in Appendix E-2 of the Larimer County Urban Area Street Standards (LCUASS) shall apply and be followed by this project as applicable. " Response: The requested notes have been added to Sheet 1 of 2 as requested. Number. 24 Created. 1/12/2007 [1/12/07] From Technical Services: Please label the accessory building. Response: The Accessory Building has been labeled on the Sheet 1 of 2 (Site Plan). Number- 25 Created: 1/12/2007 [1/12/07] From Technical Services: Please show lot and block4egal information on the site plan. Response: The lot and block information has been added to the Sheet 1 of 2 (Site Plan) as requested. Department: Light & Power Issue Contact:. Bruce Vogel Topic: General Number- 4 Created: 11412007 [114107] Owner needs to decide how he wants to bring power to the new building. If he brings it from existing panel- no involvement from us. If he wants a separate feed- development charges will apply. Responses to Comments of 1/12/07 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I Number. 13 Created: 1 /9/2007 [1191071 The FAR calculation is incorrect on the site plan. For the purposes of calculating density, "total floor area" shall mean "the total grass floor area of the ground floor of any accessory building larger than 120 sq. ft. plus that portion of the floor area of any second story having a ceiling height of at least 7 1/2 feet located within any such accessory building located on the lot." This definition should also be used to calculate the FAR. Using this definition, 1 calculate a FAR of .20 on the rear 50% of the lot, not .0777. Response: The revised FAR calculation is provided on Sheet 1, below the site plan. The upper half story has been removed from the proposed design. Therefore, the gross floor area is 600 sq. ft., the rear half of the lot is 4,875 sq. ft., resulting in a calculated FAR of 0.123. Department: Engineering Issue Contact: Susan Joy Topic: General Number.- 16 Created: 111012007 [1/10/071 Please show, dimension and label existing sidewalks, driveways, etc. More detailed comments will be given when the plans become clearer. Stormwater and Engineering has agreed that a site/landscape plan is sufficient and we will not require a utility plan set. However, to avoid problems pulling your building permit later, we will want to have 3 paper copies of the final signed mylars submitted for distribution once the project is ready to record. Since no utility plans will be filed, there is no other way for the certain departments to know that you have submitted any plan set whatsoever so we have to do it another way. No worries. Response: The existing front sidewalk is shown and dimensioned on the revised Site Plan as requested. There are no rear lot sidewalks. The rear drivewaylparking area is covered by the proposed 30' x 25' driveway slab. The requested paper copies of the final mylars will be provided once the Final design is approved and the mylars signed.. Number.- 21 Created. 1/12/2007 [1/12/07] All parking must be paved in accordance with the Land Use Code. See LCUASS for parking dimension requirements. Response: The proposed drive is concrete and will be constructed in accordance with the appropriate standards in Section 22.5 of LCUASS. Responses to Comments of i112/01 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I inches to the south). An 8 ft wide, 6 inch deep strip of aggregate will be placed on the south side of the structure to support side yard access. The existing maple trees and cotton wood trees will remain as shown. . Topic: Site Plan Number.- 5 Created: 11812007 [118107] Please include the Director of Planning and Owner Signature Blocks on the Site Plan (blank copies are attached). These Signature Blocks do not need to be signed or notarized until the project is finalized and ready to be recorded. Response: The Director of Planning and Owner Signature Blocks have been added to the revised Site Plan as requested. Number.• 6 Created: 11812007 [118107] Please dimension existing street sidewalk and parkway (area between curb and sidewalk) widths. Response: The dimensions of the existing street sidewalk and parkway have been included to the revised Site Plan as requested. Number 7 Created: 11812007 [1181071 The siteflandscape plan is difficult to read. Please differentiate between existing and proposed conditions by using varied line weights and symbols. For example, clearty identify the building footprint, concrete pad/sidewalk, irrigated beds and rock areas. Also, are there any existing fences on the property? If so, please indicate where/what type. Response: The requested improvements to the site/landscaping plan have been added. Number.' 8 Created: 11812007 [1181071 Please include a small vicinity map on the site plan. Response: The requested small vicinity map has been added to the site/landscaping plan. Number. 9 Created. 11812007 [118107] Please do your best to show existing adjacent buildings and uses on the site plan. Response: The small vicinity map that has been added to the site plan illustrates the existing adjacent buildings and uses. Responses to Comments of U12/07 226 PETERSON STREET ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I ISSUES: Department: Current Planning Issue Contact: Shelby Sommer Topic: General Number. 2 Created: 1WO07 [113107] The following departments and agencies have indicated that they have no concerns with this proposal: Comcast, Park Planning, Historic Preservation, Xcel Energy, Post Office, GIS, and Forestry. Response: Noted, thanks. Number. 3 Created: 11312007 [1131071 Rick Lee with the Building Department has attached a copy of the building codes and standards that will be enforced with this proposal. Response: Noted, Thanks. Number. 10 Created: 11812007 [118107] The Statement of Planning Objectives references letters of consent from adjacent land owners. Unfortunately I did not receive these letters in my packet of plans and would like a copy of these letters with the next submittal for the project file. Response: The Statement of Objectives should have only indicated a letter from one adjacent land owner, now included with this response. The upper half story has been removed from the revised design. However, as there is no longer any upper half story in the revised design, the issue of impacts to adjacent property privacy is moot, these windows provide interior light only. Number. 11 Created: 11812007 [118107] Several of your documents indicate that the proposed building will be 2 stories in height. Maximum building height for accessory buildings with habitable space is 1 1/2 stones (24 feet). Response: The identified references were intended address the upper half story shown in the design, not an entire 2nd story. The upper half story has been removed from the revised design. Number: 20 Created: 111112007 [1/11/07] Dana Leavitt (Environmental Planner): Please clearly show landscaping on site plan or provide separate landscape plan. Response: The landscape plan is identified on the revised Site Plan. Cedar mulch or equivalent will surround the rear lot and structure as shown (8 ft wide on North, 5 ft wide on West where it abuts existing irrigated turf, 18