HomeMy WebLinkAboutMOUNTAIN VIEW COMMUNITY CHURCH - FDP - 31-07/A - SUBMITTAL DOCUMENTS - ROUND 1 -There is a landscape island that includes two shade trees and a light fixture with double lamps. Over the long term, this will result is less illumination reaching the surface of the parking lot. Please consider moving the light fixture away from the trees to avoid light loss. The light fixture has been moved from the parking island. The fixtures in the luminaire schedule need to be specified as "full cut-off." The specification sheet stating "full cut-off' for the light fixtures has been added to the photometric sheet Please let us know if you have any other issues. Sincerely, Sandy McFeron Project Manager V.F. Ripley Associates, Inc. Kevin Brazelton Project Engineer Northern Engineering Services Department: Stormwater- Water- Wastewaterlssue Contact: Wes Lamarque Topic: Floodplain Number: 39 Created: 111912007 [12/18/07] The building is not in any 100-year f/oodplain, but the building is in the Poudre River 500-year foodplain. No critical facilities would apply. This includes daycare as stated in the conceptual comments. Please contact Marsha Hilmes- Robinson for more information at 224- 6036 [1119107] Please discuss in the text of the report that the building will not be located in any foodplain. Acknowledged. Topic: Stormwater Number: 42 Created: 1211812007 [12118107] Please update text in drainage report. See redlines. The text has been updated. Number: 43 Created: 1211812007 [12118107] Stormwater is ready for a hearing. Acknowledged. Please consider a "multi -use" detention pond. It may be advantageous for the church to provide for outdoor recreation, informal gathering or passive recreation in such a large detention pond. There are two examples where this was successfully done and both on South Timberline Road. The first is just north of Lowe Street near GK Gymnastics and Triple Crown Sports. The second is just north of Battlecreek Drive. The Stormwater Utility is willing to work with the applicant on creative approaches that can provide dual use. The detention pond has been re -configured and the pans relocated to allow for a more useable outdoor space such as ball fields. Comment from Current Planning: Please shift or add shrubs to screen the electrical transformer from Buckingham Street. The transformer has been relocated and screened on three sides with shrubs. Number: 35 Created: 11/7/2007 [12118107] The response letter indicated that drainage is being directed under the sidewalk with a culvert though / don't see this indicated on either side of the driveway. [11/7/07] 1 wasn't able to ascertain if drainage is being directed off the driveway onto Buckingham over the sidewalk. How much spillage (if any) occurs over the sidewalk? The water from the driveway is being directed in the interim condition to the existing roadside swale on the south side of Buckingham. The construction project will be redefining this swale. In the ultimate condition the water will continue in curb and gutter to an inlet/curb chase as shown on the preliminary Buckingham plan and profile. Number. 45 Created: 1211812007 [121181071 At the time of final plan submittal please specify curb and gutter extent along Ninth Street with stationing. The curb and gutter has been stationed along Ninth Street on the construction plans Topic: General Number: 20 Created: 111612007 [12118107] I'm fine with the applicant's response, though / believe some sort of acknowledgement from PRPA should be received prior to hearing that they don't object to the project going to hearing (or have no comment/concerns with the propsal.) [1116107] It appears that the Platte River Power Authority would need to be a signatory to the plat as well as construction drawings, having an exclusive easement and facilities within the property boundary. Tom McCormick with PRPA provided comments that were forwarded to the City. Tom McCormick stated that PRPA does not need to sign the Plat or Construction drawings, but will continue to review them as the project proceeds. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 46 Created: 1211912007 [12119107] PFA has no additional comments or concerns at this time. Acknowledged. only need to include construction costs (curb and gutter, pavements, etc.) (The design should demonstrate that the curb and gutter installed along the western property boundary can remain otherwise curb and gutter in this location would also need to be included in the escrow). If the project's design along Buckingham is limited to the preliminary portion only then the local street portion escrow will need to include design costs to ensure curb and gutter and pavement can be built to an ultimate condition. The preliminary design information has been added. Number. 25 Created: 111612007 [12/18/071 Shouldn't the truncated dome alignment on the north side of Buckingham be angled to direct a pedestrian towards the southwest rather than southeast? [1116107] I'd like to do some further follow-up on the existing asphalt sidewalk and how it is affected by the widening shown for the left turn lane. It appears that the asphalt sections of walk may need to be reconfigured with the road widening. Also, it may be necessary to provide detectable warnings (truncated domes) for the walks as they approach the intersection. The truncated dome alignment has been updated. Number: 26 Created: 111612007 [12118107] The angle point elimination is evident on the striping portion of Buckingham Street though an angle point is specified at the edge of pavement (19+75.7). Can this also be revised to be a curved section? [1116107] The Lemay design for the turn lanes creates angle points where the transitions occur for the left turn lanes, I'd like to see these shown smoothed out with curves rather than the angle points for driveability concerns. The angle point has been eliminated on the edge of pavement. Number: 27 Created: 111612007 [12118107] The cross slopes appear fine in the revised drawing. Please note that I did not come across a variance request letter for the .4% grade specified in the response letter, though I don't see this being required prior to hearing. [1116107] The cross sections for Lemay show instances where the additional pavement widening is at less of a cross slope than the existing portion, which is of concern and does not meet standards. Acknowledged. An additional hard copy of the variance request has been submitted. a ^ V �IPIt,=yASSCCIATES INC Landscape Architecture Urban Design Planning February 27, 2008 Mr. Ted Shepard Fort Collins Planning Department 281 North College Avenue Fort Collins, CO 80524 RE: Mountain View Community Church PDP — TYPE I Response to staff Project Review comments Dear Mr. Shepard: We have reviewed the staff letter dated December 20, 2007 and have the following comments: ITEM: Request for neighborhood community church COMMENTS: Department: Engineering Issue Contact: Marc Virata Topic: Construction Plans Number: 22 Created: 111612007 [12/18/07] Carried over for reference. [11161071 Please add the preliminary design information for Lemay and Buckingham done with the Lincoln Park project onto the construction plan set (as was done on the site plan). This information isn't as necessary on the site plan, but should be shown on the construction plan set as a reference. This information should be complete with stationing, tangent and curve data. The preliminary design information has been added to the preliminary Buckingham Street Plan and Profile sheet. Number: 23 Created: 111612007 [12118107] Carried over for reference. [11/6/07] The construction plan set needs to show vertical design information specific to Buckingham/Duff carried from the Lincoln Park project and then have it preliminarily designed along this project tying back to the west. If the project were to then also do a full design of Buckingham (flowline and centerline design, cross sections, etc.) then the local street portion escrow for Buckingham would Phone 970.224.5828 Fax 970.224.1662 401 West Mountain Ave. Suite 201 Fort Collins, CO 80521-2604 vhipley.com