Loading...
HomeMy WebLinkAboutADVANCE AUTO PARTS - PDP - 26-07 - SUBMITTAL DOCUMENTS - ROUND 2 -ADVANCE AUTO PARTS FUTURE ACCESS TO SOUTH 09/18/2007 PUBLIC IMPROVEMENTS I. TRANSPORTATION 1 6" Vertical curb and gutter LF $16.00 45 $720.00 2 5" Asphaltic Pavement SY $16.00 66 $1,057.76 3 Concrete walk SY $46.00 12 $552.00 TOTAL $2,329.76 Number. 4 Created. 811712007 [8117/07] The "site data table" on the site plan lists the land use as "commercial'. The specific use or uses proposed must be listed in order to ensure that the proposed uses are Type 1 uses, not Type 2 uses. The site data table has been updated. Number: 5 Created: 811712007 [8117107] Need 3 to 4 trees in the 5' landscape strip along the south lot line (Section 3.2.1(E)(4). Need foundation plantings per Section 3.2.1(E)(2)(d) Low-water foundation plantings have been provided along the south boundary. We may not water in this area due to the neighboring building being located right on the property line. Therefore, trees cannot be located in the 5-foot strip. Trees have been provided in the landscaped islands near the south boundary. Number: 6 Created. 811712007 [81171071 Note #1 on the site plan indicates that the dumpster enclosure is wood. However, the enclosure detail on the exterior elevation page indicates it's block. Which is it? The dumpster enclosure is block Number: 7 Created: 811712007 [81171071 Remove the monument sign elevation from the exterior elevations sheet. Monument sign has been removed. Number: 8 Created: 811712007 [81171071 Wall mount light fixtures are shown on the elevations. Need to add note that they will be down directional, shielded, etc. Note added Page 13 [8128107] City records show only one sanitary sewer in the alley; however, utility plans show two. Please clarify. The plans have been revised to correctly show only one sanitary main in the alley. Number: 27 Created: 812812007 [8128107] If separate irrigation meter is planned, a second water service is required from the main to the meter. The two water services (domestic and irrigation) may be in the same trench approximately 3 feet apart. A separate tap for the irrigation meter is now provided. Number: 28 Created: 8/28/2007 [8128107] If any sewer service clean -outs are in hard surfaced areas, label as "traffic rated" and include City standard detail. The clean -outs in the pavement are now labeled as "traffic rated". Number: 29 Created: 8/28/2007 [81281071 Sewer service and gas service are very close together. City does NOT maintain the sewer service; however, from a maintenance standpoint, this will be difficult for owner to maintain. The sanitary service lines have been relocated. Number. 30 Created: 812812007 [81281071 See plans for other minor comments. Redlined comments have been addressed. Department: Zoning Issue Contact: Peter Barnes Topic: Zoning Number: 3 Created: 811712007 [8117107] The lot depth dimension on the site plan is indicated to be 190'. However, an additional 17.5' of ROW is being dedicated, meaning the lot depth is only 172.5. The site plan needs to reflect the new lot dimensions and the property lines need to be labeled as such on the site plan. The site has been labeled with the new property dimensions after the ROW is dedicated. Page 12 Number: 55 Created: 813112007 [8131107] EMERGENCY NOTIFICATION: The HMIA states that in the event of a problem with hazardous materials, employees are to call Advance's Environmental Health and Safety Program. Please stress to employees the importance of calling 911 for an emergency response in the event of a serious hazardous materials incident. Noted Department: Stormwater-Water-Wastewaterlssue Contact: Wes Lamarque Topic: Floodplain Number: 64 Created: 813112007 [8131107] Please add a note on the plat, site plan, and grading plan stating the entire site is within the FEMA Dry Creek 100-year Floodplain. Note has been added as requested. Number: 65 Created. 813112007 [8131107] Please add a note on the Drainage Plan stating what the regulatory elevation for the structure is ( BFE + 18 inches), that a variance is being requested for BFE + 12 inches, and state the BFE elevation. A note has been added to the Drainage Plan as requested. Number: 66 Created. 813112007 [8131107] Please edit the text in the report per redlines. Redlined comments in the report have been addressed. Topic: Stormwater Number. 53 Created: 813012007 [8130107] Please revise detention calculations to reflect one 2-year release rate. This basin defines the release rate to be .2 cfs per acre and dual release rates are not utilized. The detention pond release rate has been revised to 0.2 cfs per acre. Number. 67 Created: 813112007 [8131107] If the sidewalk along the detention pond is to be moved next to the pond, the sidewalk can act as the spillway and provide erosion protection. The rip -rap for the emergency overflow weir has been deleted because the sidewalk is now located immediately east of the detention pond. Department: Stormwater-Water-Wastewaterlssue Contact: Roger Buffington Topic: WaterMastewater Number: 26 Created: 8/28/2007 Page I 1 [81311071 E 114 misslabeled in legal on Plat. Section corner label has been corrected. Number. 60 Created: 813112007 [8131107] Add - Being a replat of ....... (see redlines) "A replat of..." has been added at the top of the sheet as requested. Number: 61 Created: 813112007 [81311071 Show Hickory in Vicinity Map. Hickory has been added to the vicinity map. Number: 62 Created: 813112007 [8131107] Show how College ROW varies ... how was College dedicated (Plat of Riverside Park) The ROW width does not vary in front of the project site. Recording information for College Avenue has been added to the plat. Number: 63 Created: 813112007 [81311071 Line over text issues to be corrected on the Site Plan. See redlines for additional minor comments. Line over text issues have been corrected. Department: Light & Power Issue Contact: Alan Rutz Topic: General Number. 25 Created: 812812007 [81281071 Power is available at the southwest corner of the site. Contact Light and Power to discuss transformer location. Transformer location has been discussed with Light and Power. Department: PFA Issue Contact: Carie Dann Topic: Fire Number. 54 Created: 813112007 [81311071 WALL HYDRANT.- What is labeled the site plan (actually, it's elevations) shows item #20 on the building as being a wall hydrant. Is this actually what it's supposed to be? Should it actually be a sprinkler FDC? What would be the need for having a wall hydrant, if that's what it actually is? As per Advance Auto Prototype there will be a Hose Bibb, commonly known as a Wall Hydrant. Page 10 Number: 52 Created: 812912007 [81291071 Please revise the Site and Landscape plans accordingly to reflect all changes requested on the Utility Plans related to sidewalks, ramps, on -site medians etc... Site and landscape plans have been updated. Number. 56 Created: 813112007 [81311071 The parking spaces off of College Avenue do not meet the minimum set back requirement (measured from future flow line which is 16 feet from ROK9. Please see LCUASS Table 19-6 for set back requirements based on the ADT provided in. the traffic study submitted. Minimum set back is 50 feet but could be more based on ADT. The parking lot has been pushed back to be a minimum of 50 feet from the ultimate curb line. 2. Traffic Engineer for development requested a reduced 'Minimum Off Street Parking Setback Distance" from 75' (per LCUASS) to 50 feet. Reviewing the site and traffic characteristics of the area I can support the request. (Email received from Shelby Sommer 9117107) Number: 57 Created: 813112007 [8131107] As discussed in the staff review meeting, the cross lot access area (SE corner near driveway) may be landscaped and money may be escrowed for future paving, curbs, ramp and sidewalk. A detailed cost estimate must be prepared by the developer and submitted for review. The escrow will be specified in the development agreement and will be due at the time of building permit. The access easement will need to be dedicated on the Plat to ensure a future connection can be made and utilized if needed. The access to the south has been deleted and landscaped. A cost estimate is provided with this resubmittal. An access easement has been added to the plat. Number: 58 Created: 813112007 [8131107] It is estimated that College improvements in front of this site may be started as early as 2009 to accommodate the new Vine Drive alignment intersecting College Ave. This may require widening College in front of this site to accommodate two left turn lanes onto Vine. This will require the access on College to be permanently closed. Please provide a bold note on the Plat that indicates that the City or CDOT may close the College access at the time improvements are completed. This phase of College improvements may not affect other parcels on College with existing access driveways ... not all accesses will likely be closed at this time. Reviewing with Counsel Topic: Technical Services Number: 59 Created: 813112007 Page 9 A public access easement has been added to the plat and utility plan as requested. Number: 44 Created: 8/29/2007 [8129107] Please show and label the approximate limits of street cut needed for utility connections and add the standard street cut note to the plans. Street cuts for utility construction have been added to the plans. Number: 46 Created: 812912007 [8129107] Please provide cross sections with the grading plan to show how the on - site landscaped medians at the perimeter will tie into the existing grades will not drain water onto the adjacent property. Cross -sections have been added to the grading plan as requested. Number: 47 Created: 8/29/2007 [8129107] Please show the existing building location on the adjacent parcel to the south. The existing building to the south has been more clearly labeled. Number: 48 Created: 812912007 [8129107] The plans show a 2 foot sawcut to install curb and gutter on College. The pavement will also need to be milled and overlayed to the nearest lane line along the length of the street cut. Please show and label this on the plans. A note to mill and overlay to the nearest lane line has been added to the plans. Number. 50 Created: 8/29/2007 [81291071 An access permit is required from CDOT. You may submit an application to CDOT concurrently with the City review and the City will coordinate with CDOT such that the access permit can be issued when the plans are approved. CDOT permit being processed. Number. 51 Created: 812912007 [81291071 Please show the street tree locations on College on the Utility Plans. The location of street trees on College is important such that the trees will not need to be removed or relocated when College is widened. Please space the trees with respect to the ultimate sidewalk location rather than centering them in the parkway between the sidewalk and curb. Street tree locations have been added to the Utility Plans. Street trees have been placed in conformance with the ultimate roadway section. Page 8 Number 35 Created: 812912007 [8129107] The detached sidewalk on College must be located in the ultimate location at the ROW line so that it will not need to be removed when College is widened (when Vine is relocated). The sidewalk will also need to be a min. of 6 feet wide to meet the arterial standard. Due to the detention ponds location with respect to the ROW on College, a safety hand rail will be required where the pond is adjacent to the sidewalk. It appears the overflow weir will also need to be modified where the sidewalk conflicts. The sidewalk has been moved to the ultimate location, and is now shown and labeled as 6 feet wide. The rip -rap protection for the overflow weir has been deleted, and a handrail is specified for the retaining wall. Number: 38 Created: 8/29/2007 [81291071 The detached sidewalk on College will need to extend all the way to the south property line in the ultimate location with a type III barricate installed at the south end. This will require the cross lot access dsign to change or narrow. If the cross lot access is reduced to less than 20 feet wide it may need to be a one way controlled access with signage installed. Please indicate with your next submittal how this cross lot access to the south adjacent parcel will function. The access drive and sidewalk to the property to the south has been deleted. Number: 39 Created: 8/29/2007 [8129107] The College driveway access must be constructed per LCUASS DWG 707 with ped ramps and connecting sidewalks on both sides. Please show and call out on the plans. The driveway and handicap ramps have been drawn per Drawing 707. Number: 40 Created: 8/29/2007 [8129107] The sidewalk on Hemlock should be straightened on both ends and standard directional ramps should be installed at the alley intersection and across Hemlock at College. The sidewalk has been straightened as requested. A directly handicap ramp has been provided at College and Hemlock. A ramp is not required at the alley crossing, but truncated domes have been called out at this location. Number. 41 Created: 8/29/2007 [8/29/07] A public access easement must be dedicated on the Plat and shown on the Utility Plan drawings which connects the adjacent parcel to the south (cross lot access) to the alley. The public access easement must be a minimum of 20 feet wide. Please see redlines for clarification. Page 7 Please contact Megan at 970-498-7065 if you have questions regarding these comments. All of Lot 7 is now included on the plat, and the owner of the south portion of Lot 7 has been added as a signatory. The legal description point of commencement has been corrected. Topic: Site Plan Number: 10 Created: 812012007 [8120107] Please clearly label right-of-way, easements and building setbacks on the site plan. See redlined site plan for small typos and corrections. Lines on the site plan have been clarified as requested. Department: Current Planning Issue Contact: Dana Leavitt Topic: Site Plan Number. 36 Created: 8/29/2007 [81291071 In addition Peter Barnes' comments regarding the trash enclosure, the interior space must be able to accommodate both trash containers and recycling containers. Show a plan with dimensions for both length and width with containers within structure per Section 3.2.5 of the Land Use Code. Department: Engineering Issue Contact: Randy Maizland Topic: Engineering Number: 33 Created. 812912007 [8129107] No alley improvement design was submitted. The 20 foot alley off of Hemlock must be improved to either 7-11 F or 7-12F and 500 feet of off -site preliminary design must be provided. The alley intersection must also be reconstructed to the current standard. A sheet has been added to the set for a plan and profile of the alley. We do not currently have mapping for the portion of the alley south of the project site. The design will be enlarged to include this area once mapping has been obtained. Number. 34 Created. 8/29/2007 [8129107] The existing street flowline on College Avenue is not in the ultimate location. Any new curb and gutter construction/reconstruction on College is only an interim condition. This development will be required to escrow money for future ultimate curb and gutter on College for the entire length of the College frontage. The College access will be permanently removed and replaced with curb and gutter in the future. The escrow payment will required prior to the issuance of a building permit and will be specified in the development agreement. The developers engineer shall prepare a cost estimate for the City to review for design and construction. A cost estimate of future construction quantities and costs is provided with this resubmittal. Page 6 Plant selections have been revised per redlined comments. Number. 49 Created: 812912007 [8129107] Planting Plan labeling needs to be accurate and clear to read. See redline comments. Plant schedule and quantities list should be combined, with unique symbols for each species of plant. Planting plan has been revised per redlined comments. Department: Current Planning Issue Contact: Shelby Sommer Topic: Lighting Plan Number. 18 Created: 812112007 [81211071 Maximum on -site lighting levels shall not exceed 10 foot candles. Please see problem areas highlighted on lighting plan, specifically the recessed lighting near the building entrance. I would recommend that you reduce the quantity of fixtures in this area to provide better uniformity and transition. Light levels measured 20 feet beyond the property line shall not exceed 0.1 foot candle (see highlighted areas that exceed this level). Noted and corrected Number. 19 Created: 812112007 [8121107] Light pole finish color (Fixture type AA) should be a color other than red to blend in with the site, not stand out (black, silver etc.) Wall mounted fixtures should be in a color that matches and blends in with the building exterior. We have changed the light pole finish color to black Topic: Plat Number: 20 Created: 812112007 [81211071 Megan Harrity (Assessment Specialist - County Assessor's Office): I have reviewed the preliminary plat for the Advance Auto Parts PDP. I have a couple of concerns and I have enclosed two copies of the Assessor's Property Profile sheets, both of which may be part of the proposed Auto Parts plat. Lot 7 is split between two separate parcels. The North 22 feet belong to Rush Family LLC and the South 3 feet belong to Trinity Investments Limited, College Lofts LLC and E.L. & Linda Black. All owners of Lot 7 will need to sign the final plat. Also, the written portion of the legal description commences at the southeast corner of said section 2, when it should begin from the southeast quarter corner. Page 5 Number: 15 Created: 812012007 [8120107] Repeat comment from Zoning: foundation plantings and parking lot perimeter plantings are required. An alternative compliance request must be submitted if you cannot provide perimeter plantings as required due to the proximity of the existing building. Low-water plantings have been added along the north and east sides of the building, plus along the south boundary. Number. 16 Created. 812012007 [8120107] The southernmost landscape island in the parking lot must be at least 8 feet in its smallest dimension, and at least 80 square feet total. It looks like you're close to 8 feet wide, but not quite. Please confirm. The landscape island has been widened to 8 feet. Number: 17 Created: 812012007 [8120107] Please add the tree protection specifications located in Section 3.2.1(F) of the LUC to the landscape plan or add note that trees will be protected per the specifications in this section. Tree protection notes have been added to the landscape plan. Department: Current Planning Issue Contact: Dana Leavitt Topic: Landscape Plan Number: 42 Created: 8/29/2007 [8129107] Numerous spelling errors for species name on plan - correct. Show all plants at mature size. For example, an Autumn Purple Ash will have a canopy more than Pin diameter at 10 years and will continue to grow well beyond 20' by the 20th year. Spelling errors have been corrected. Plants and trees have been shown at mature size. Number: 43 Created: 8/29/2007 [81291071 Provide a list of native grass species and the application rate for seeding. Seeding specifications have been added to the landscape plan. Number: 45 Created. 812912007 [8129107] There are inappropriate selections of plant materials numerous locations. For example, the Colorado Spruce tree located between the loading dock and the trash enclosure will grow to overwhelm the 10' space in the island, thus reducing the function of both features. Refer to the plan for additional comments pertaining to selection. Page 4 Department: Current Planning Issue Contact: Dana Leavitt Topic: Grading Plan Number: 37 Created: 812912007 [81291071 Add Tree Protection Notes to the Grading Plan per Section 3.2.1 of the Land Use Code. Tree protection notes have been added to the grading and landscape sheets. Department: Current Planning Issue Contact: Shelby Sommer Topic: Landscape Plan Number: 1 Created. 811312007 [81131071 Please see the attached comment sheet from Water Conservation (Laurie D'Audney) regarding Landscape Plan requirements. Noted. Number. 11 Created. 8/26/2007 [8120107] Street tree selections must be from the City's approved street tree list (see attached). Swamp White Oak is not a species on this list. Approved street trees are now specified along College. Number. 12 Created: 812012007 [81201071 Street trees must be placed at 30 to 40 foot spacing. An additional street tree is required along College Ave. Three street trees are now shown along College at 35-foot intervals. Number. 13 Created: 812012007 [8120107] "Full tree stocking" is required along high visibility sides of the building. Please see Section 3.2. l (D)(1)(c) of the LUC for specifics. This pertains especially to the eastern edge of the building along College Ave. Low-water plantings have been added along the north and east sides of the building. Number. 14 Created: 812012007 [8120107] Several of the trees listed as deciduous shade trees are not deciduous species. Please include these in a separate table for coniferous species, with height specifications, not caliper. Deciduous and coniferous trees have been labeled correctly and placed in tables as requested. Page 3 without substantial variation including changes in height and projecting/recessed elements. We have added pilasters that are brick along the north side of the building to break the fagade of the wall along Hemlock. We have also increased the height difference in the center part of the wall to add interest. Number. 24 Created: 812812007 [8128107] Facades that face the street or connecting pedestrian frontage need to be proportioned for pedestrians with features such as windows, arcades, arbors etc. The North elevation facing Hemlock St needs to be revised to satisfy the standard located in Section 3.5.3(D)(3). Please refer to the North College Corridor Plan's guidelines for further standards relating to materials and architectural elements. We strongly encourage the use of brick instead of block, metal elements and a semi - industrial character to set the stage for future redevelopment in this area. We have added more brick as well as pilasters to create a more interesting fagade. Topic: General Number., 2 Created: 811712007 [8117107] The following departments/agencies have no concerns with this proposal: Park Planning, GIS, Real Estate Services, Comcast. Number: 9 Created: 812012007 [8120107] The Grading Plan should be included with the Utility Plan set, not the Site Plan. The Existing Conditions Plan is helpful, but not required and will not need to be recorded with the rest of the development plan documents. The grading plan and existing conditions plan have been removed from the site plan set. The grading is already included in the Utility Plan set. Number: 21 Created: 8/23/2007 [8123107] Attached are the applicable Building codes and standards. Please schedule the required Pre -Submittal Code Review Meeting. Noted Number: 22 Created: 8/23/2007 [8123107] Bonnie Ham (Growth Coordinator - US Postal Service): Mailbox will be a rural style box either on College or just inside parking lot. For more information contact Bonnie at bonnie.j.ham@usps.gov or USPS, 301 E. Boardwalk, Fort Collins, CO 80525. Noted Page 2 1'-G�� Olnlc r, "t b Gaw�w��v Department: Advance Planning Issue Contact: Clark Mapes Topic: Architectural Elevations Number. 31 Created: 812812007 [8128107] Per our previous conversations, Fort Collins has standards that "break the mold" of shoebox-style corporate boxes - refer to 3.5.3(C) and (D). Standards require responsive, creative architectural design. The 2007 North College Corridor Plan explains the approach to distinct local character in this area. This is particularly important to the community. The red brick is a positive element in this regard. However, additional variation in the height/width ratio should be added, with additional height used to highlight the street front and entrance.' The additional height offers opportunities for more architectural interest and character. The North College Plan describes a semi -industrial character, possibly in combination with traditional characteristics of Downtown, noting the use of brick instead of block, metal instead of artificial stucco in architectural design; use of glass, deep protrusions and recesses, juxtaposed forms, awnings, color, exposed structural elements, and significant, functional roof forms to add height and interest to one-story buildings. Staff will bring a number of redline questions and suggestions for further consideration and discussion with the developer and architect. In order to correspond with the North College Corridor Plan, we have made the height differences more dramatic both at the entrance and the north side facing Hemlock. We have made more surfaces with red brick and changed the color of the integral block to be a darker color to contrast with the red brick nicely. Topic: Site Plan Number: 32 Created: 812812007 [8128107] Sidewalks need minor adjustment and detailing for user -friendliness - e.g. ease corners, adjust alignments to remove minor discontinuities. Sidewalks have been revised as requested. Department: Current Planning Issue Contact: Shelby Sommer Topic: Architectural Elevations Number: 23 Created: 8/28/2007 [8128107] Per Section 3.5.3(D)(3) of the Land Use Code, no wall that faces a street or connecting walkway shall have a blank, uninterrupted length exceeding 30 feet without including at least 2 of the following: change in plane, change in texture or masonry pattern, windows, treillage with vines, or an equivalent element that subdivides the wall into human scale proportions. See redlines for areas that exceed this 30 foot requirement and revise elevations to meet the minimum wall articulation standards. Please include changes in height in addition to projected/recessed elements. Pay specific attention to the building entrance, the long, blank wall facing the parking lot near the building entrance and the Hemlock fagade. Massing of the building should not exceed a width to height ratio of 3 to 1 Page 1