CONCEPTUAL REVIEW STAFF COMMENTS
1. The existing electric feed is located in the alley behind the property (3
phase, single phase also available). Acknowledged
2. Normal development fees will apply, and the closer the transformer to
the service in the alley, the better. Acknowledged
ENVIRONMENTAL PLANNING
Contact Info: Dana Leavitt, 224-6143, dleavitt@fcgov.com
1. A trash enclosure large enough to accommodate recycling services
will be required. Acknowledged
2. Please indicate whether you intend to preserve or remove any existing
trees on the property. Tree removal must be approved by City
Forester, Tim Buchanan, and may require mitigation. For more
information contact Tim at 221-6361. Acknowledged
ADVANCE PLANNING
Contact Info: Clark Mapes, 221-6376, cmapes@fcgov.com
1. This property falls within the North College Corridor Plan area. This
plan calls for corporate prototype buildings to be modified to local
circumstances and variation in building massing. Tax increment
financing may be available for this project. Please contact me for
more information. Acknowledged. Please see planning objectives for
more information.
CURRENT PLANNING
Contact Info: Shelby Sommer, 221-6750, ssommer@fcgov.com
1. This development proposal is subject to all applicable standards of the
Fort Collins Land Use Code (LUC), specifically Article 3 General
Development Standards, and Division 4.23 Commercial — North
College District. Acknowledged
2. The entire Fort Collins Land Use Code (LUC) is available for your
review on the web at
http://www.colocode.com/ftcollins/landuse/begin.htm Reviewed
3. An overview of the Development Review Process can be found online
at http://fcqov.com/currentplanninq. Reviewed
4. You will be required to submit a Project Development Plan (PDP) for
review. The PDP fee schedule and submittal requirements can be
found online at http://fcgov.com/currentplanninq/submittals.php.
Reviewed
5. Please contact me if you have any questions about the code
requirements or need some help figuring out your next steps in the
Development Review Process. Acknowledged
6. When you are ready to submit your PDP application please call the
Development Review Center at 970-221-6760 to schedule a PDP
submittal appointment. Acknowledged
11
ia
CityofFortCollins CONCEPTUAL REVIEW STAFF COMMENTS
5. You will be responsible for dedicating additional right-of-way and utility
easements as needed. College Ave. is classified as a 4 lane arterial
and you will be required to dedicate a total 57'/2 feet of right-of-way,
or potentially a little more to accommodate a % median in the future
(See Long Term Access Plan and LCUASS 7-2F). Hemlock must be
constructed as a Commercial Local (See LCUASS 7-6F) and there is
adequate existing right-of-way. Acknowledged
6. Standard utility easements are required behind the right-of-way on
College, Hemlock and the alley. A 15 foot utility easement will be
required along College, a 9 foot utility easement is required along
Hemlock and an 8 foot utility easement is required along the alley. No
structures may be located in utility easements. Please see letter to get
a variance granted for the easement on Hemlock.
7. Utility Plans, a Development Agreement (DA), Development
Construction Permit (DCP) and Subdivision Plat will be required.
Provided
8. A CDOT permit will be required with this proposal. Please see
attached
9. Alley improvements will be required along this property's alley
frontage to the nearest street. See LCUASS 7-11 F or 12F for alley
standards. Acknowledged
10. Damaged curb, gutter and sidewalk existing prior to construction, as
well as streets, sidewalks, curbs and gutters, destroyed, damaged or
removed due to construction of this project, shall be replaced or
restored in like kind at the Developer's expense prior to the
acceptance of completed improvements and/or prior to the issuance
of the first Certificate of Occupancy. Acknowledged
11. Any existing overhead utility lines will need to be undergrounded with
this project. Acknowledged
12. The short term access plan for this area requires a
consolidated/shared access on College with the adjacent property.
Acknowledged
13. Parking setbacks must be met on College and Hemlock.
Acknowledged
14. Only one curb cut will be allowed onto the alley. It may be possible to
have another curb cut on Hemlock for circulation when the College
access is eliminated. Acknowledged
15. No signage is allowed in the right-of-way. Acknowledged
16. You will be required to escrow money for the future College Ave.
improvements. Acknowledged
LIGHT & POWER
Contact Info: Janet McTague, 221-6700, utilities@fcgov.com
on
CONCEPTUAL REVIEW STAFF COMMENTS
2. The property must be located within 300 feet of a fire hydrant capable
of providing a water supply of 1,500 gallons per minute.
Acknowledged
3. The property address shall be mounted on the building in six inch
numerals visible from College Ave. Acknowledged
4. A hazardous materials impact analysis will be required with this
proposal. Provided
TRANSPORTATION PLANNING
Contact Info: David Averill, 416-2643, daverill@fcgov.com
1. No attached sidewalks are allowed in this area. You will be required
to provide a 6 foot detached sidewalk along College Ave. and a 5 foot
detached sidewalk along Hemlock. Acknowledged
2. You will be required to provide a connecting walkway between the
street sidewalk(s) to the building entrance(s). Acknowledged
3. This property will be subject to the requirements of the North College
Access Control Plan. This plan will eventually require the existing
curbcut to be eliminated and access will be shared with the property to
the south. At this time it is unclear what will be required of this
property with respect to the existing curbcut along College, and follow-
up will be required with CDOT. Since there is a building along the
south property line, we have proposed a joint access on the property
that would allow for future joint access should the adjacent property
owner choose to use it. CDOT and the City Engineer have supported
this proposal. Please see attached letter from Gloria Hice-Idler, CDOT
Region 4.
4. Please provide a bicycle rack convenient to the building entrance for
customers and employees. Acknowledged
ENGINEERING
Contact Info: Randy Maizland, 221-6605, rmaizland@fcgov.com
1. Larimer County Road Impact fees and Street Oversizing fees will
apply to this development. Contact Matt Baker at 224-6108 or
mbaker(a)fcgov.com for more information. Acknowledged
2. The Transportation Development Review Fee will apply to the change
of use project. More information is available online at
http://fegov.com/engineering/dev-review.php. Please contact Randy if
you need help estimating the fee for this proposal. Acknowledged
3. A Transportation Impact Study (TIS) will be required for this project.
Please contact Eric Bracke in Traffic Operations at 224-6062 or
ebracke .fcgov.com for further information. Provided
4. Any public improvements must be built according to Larimer County
Urban Area Street Standards (LCUASS). Acknowledged
4
6a
Ciryo(FortCollins CONCEPTUAL REVIEW STAFF COMMENTS
2. The city wide development fee is $3,070/acre ($0.0705/sq.ft.) for new
impervious area over 350 sq.ft. No fee is charged for existing
impervious area. This fee is to be paid at the time each building
permit is issued. Acknowledged
3. A drainage and erosion control report and construction plans are
required and they must be prepared by a Professional Engineer
registered in Colorado. Acknowledged
4. In the Dry Creek basin the two year historic release rate is 0.2 cfs/acre
or show that the development can release storm water from the area
into the larger system without increasing the peak discharge in the
larger system. Extended detention is required to treat the runoff.
Acknowledged
5. Floodplain Comments: Requesting a variance
- This site is located in the Dry Creek 100-year FEMA designated
floodplain. It is entirely in the flood fringe.
- The Dry Creek Flood Control Project has physically removed the
site from the floodplain; however, it will be 12-24 months before
the FEMA floodplain map is changed. Therefore, floodplain
regulations do apply however we will be happy to work with you on
how to meet them and support any variances that may be needed
while the floodplain map is being revised. Please contact the
Floodplain Administrator, Marsha Hilmes-Robinson at 224-6036.
- An approved Floodplain Use permit ($25) or Floodproofing
Certificate is required prior to release of the building permit. A
Floodplain Use permit is also required for all site improvements in
the floodplain.
- An approved as -built Elevation Certificate or as -built Floodproofing
Certificate is required prior to the release of the CO.
WATER S WASTEWATER
Contact Info: Roger Buffington, 221-6854, rbuffington@fcgov.com
1. Existing mains: 6-inch water in Hemlock, 8-inch water in College, 8-
inch sewer in N/S alley west of site. Acknowledged
2. Use or abandon at the main any existing water or sewer services that
are stubbed into the site. Acknowledged
3. Development fees and water rights due at time of building permit.
Acknowledged
POUDRE FIRE AUTHORITY
Contact Info: Carie Dann, 416-2869, cdann@poudre-fire.org
1. Fire containment or fire sprinklers are required for structures over
5,000 square feet. Your proposed 7,000 square foot building would
need to be sectioned off with a maximum of 5,000 feet per section in
order to meet the fire containment requirements. Acknowledged
3
ITEM:
MEETING DATE
CONCEPTUAL REVIEW STAFF COMMENTS
Proposed Advanced Auto Parts general retail store at the
southwest corner of Hemlock and North College Ave.
February 28, 2007
APPLICANT: Lucy Dinneen and Kay Christman
Cadence Capital Investments
8400 Orchard Rd., Suite 6900
Greenwood Village, CO 80111
IdineenCcDcadencecap.com
kch ristman (c-)cadenceca p. com
LAND USE DATA: Request to construct a 7,000 square foot general retail
building to be used for an Advanced Auto Parts store. The approximately
30,000 square foot property is located within the City of Fort Collins at the
southwest corner of Hemlock and North College Avenue and is zoned CN —
Commercial North College District.
COMMENTS: The following departmental agencies have offered comments for
this proposal based on a sketch plan and presentation to the review team:
ZONING
Contact Info: Gary Lopez, 416-2338, glopez@fcgov.com
1. General retail uses are permitted in the CN — Commercial North
College District, subject to administrative review and public hearing
(also referred to as a "Type 1 Project Development Plan").
Acknowledged
2. The building should be built to the corner of the site, no further than 15
from Hemlock and between 10 and 25 feet from North College Ave. In
the current site plan, the building is pushed up to the corner of N
College Ave and Hemlock with the above mentioned setbacks.
3. Based on the proposed 7,000 square foot building a maximum of 28
parking spaces (up to 4 spaces per 1,000 square feet) are permitted.
We have modified the site plan to have 26 parking spaces.
4. A minimum of 6% of the total interior space of the parking lot must be
landscape areas. Acknowledged
STORMWATER UTILITY
Contact Info: Glen Schlueter, 221-6700, gschlueter@fcgov.com
1. The design of this site must conform to the drainage basin design of
the Dry Creek Master Drainage Plan as well the City's Design Criteria
and Construction standards. Acknowledged
E
Community Planning and Environmental Services
Current Planning
City of Fort Collins
February 28, 2007
Lucy Dinneen and Kay Christman
Cadence Capital Investments
8400 Orchard Rd., Suite 6900
Greenwood Village, CO 80111
Idineen(a-)_cadencecap.com
kchristman(a-)cadencecap.com
Lucy and Kay:
For your information, attached is a copy of the Staffs comments for the
proposed Advance Auto Parts general retail development which was
presented before the Conceptual Review Team on February 26, 2007.
The comments are informally offered by staff to assist you in preparing the
detailed components of a project application. Modifications and additions to
these comments may be made at the time of formal review of this project.
The City's Current Planning Department coordinates the development review
process. I am the Project Planner for your project. I will be commenting as well
as assisting in the coordination process. If you have any questions regarding
these comments or the next steps in the review process, please feel free to call
me at 970-221-6750.
Sincerely,
Shelby Sommer
Associate City Planner
281 North College Avenue . P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6750 • FAX (970) 416-2020