HomeMy WebLinkAboutOLD OAK ESTATES (5227 STRAUSS CABIN RD.) - PDP - 25-07A - CORRESPONDENCE - (5)3. The nomenclature describing the 25-foot private drive is different on the plat, the site
plan and landscape plan. Please use a consistent description on all plans.
All of the 25-foot emergency & private access & utility easements are
labeled consistently.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely:
Ted Shepard
Chief Planner
P�icc 0
Comment noted and will comply.
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Stormwater
Number: 57 Created: 2/1 /2008
[2/1/08] The eastern third of the site needs to show that the flows for the minor and major
storms are not increasing by this area free releasing. The basin for this analysis needs to
include the area of the site flowing east and half of Straus Cabin Road and Big Dipper Drive
along your frontage.
In the historic conditions, 1.87 and 8.15 cfs are conveyed to the southeast corner in the
2- and 100-year storm events, respectively. In the developed conditions, 1.84 and 7.99
cfs are conveyed to the southeast corner in the 2- and 100-year storm events,
respectively. Therefore, we are not increasing the flows to the swale along the west
side of Straus Cabin Road.
Number: 58 Created: 2/1 /2008
[2/1/08] Please include in the drainage report the master plan update looking at the big
picture and how the flows have decreased in this area.
Please refer to Appendix D in the preliminary drainage report. In this appendix, there is
an exhibit showing the impacts of this development in the big picture.
Number: 59 Created: 2/1 /2008
[2/1/08] Please revise the hydrology calculations to the City of Fort Collins's criteria per the
Storm Drainage Criteria Manual.
Acknowledged: The rational method calculations have been revised.
Number: 60 Created: 2/1 /2008
[2/1 /08] A drainage easement is required for the on -site storm sewer and for certain lot
lines. See redlines.
Drainage easements have been added to the plans.
Number: 61 Created: 2/1 /2008
[2/1/08] See redlines for remaining comments.
Please see redlines for written response to redlines.
Comments from Current Planning:
1. Please revise and add notes to the Site Plan as indicated on the redlines.
Revisions have been made to the Site plan per your redlines.
2. Please add notes to the plat as indicated on the redlines.
Notes have been added to the Plat per your redlines.
Page 5
[1/28/08] Please mask all text in the street, storm sewer and sanitary sewer profiles. The
line over text conflicts do not meet LCUASS Appendix E scannability requirements. (TYP).
All text has been mask in the profiles for Sanitary Sewer, Storm and Centerline design.
Number: 55 Created: 1 /28/2008
[1/28/08] The new proposed sidewalk that terminates to the north on Strauss Cabin shall be
barricaded. Please show and call out the barricade with a detail.
A barricade and a callout has been added to the plans.
Number: 56 Created: 1 /28/2008
(1/28/08] Please refer to the redlines for additional minor comments related to drafting
and/or labeling.
Please see redlines for written response to redlines.
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 22 Created: 10/10/2007
[1/30/081
[10/10/07] WATER SUPPLY: Fire hydrants, where required, must be the type approved by
the water district having jurisdiction and the Fire Department. Hydrant spacing and water
flow must meet minimum requirements based on type of occupancy. Minimum flow and
spacing requirements include: residential within Urban Growth Area, 1,000 gpm at 20 psi
residual pressure, spaced not further than 400 feet to the building, on 800-foot centers
thereafter. These requirements may be modified if buildings are equipped with automatic fire
sprinkler systems.
97UFC 901.2.2.2
Comment noted. Proposed fire hydrants have been place at a maximum distance of
400 feet from any proposed building.
Number: 24 Created: 10/10/2007
[1/30/08] As was discussed today at Staff Review, approved signage is required at the
intersection of Big Dipper and the private drive, showing the addresses of the residences on
Lots 2-6. Also, the address numerals are required to be mounted in the residences (as well
as the sign on Big Dipper). Address numerals for both the structures and the signs are
required to be at least 6 inches in height.
Comment noted and will comply.
[10/10/07] ADDRESSING: ADDRESS NUMERALS
Address numerals shall be visible from the street fronting the property, and posted with a
minimum of six-inch (6) numerals on a contrasting background. (Bronze numerals on brown
brick are not acceptable). In addition to posting the numerals on the structures, if all lots are
addressed off Big Dipper Drive, the addresses shall be posted in an acceptable manner on
Big Dipper Drive, at each of the two driveways, showing which addresses are accessed off
each driveway. Numerals must be at least six inches in height and visible at night (reflective
and/or lit). 97UFC 901.4.4
Page 4
Number: 49 Created: 1 /28/2008
[1/28/08] Please label and call out the sidewalk chase drains proposed on Strauss Cabin
Road. You may want to consult with Wes Lamarque in Stormwater as it is his opinion that
these sidewalk chase drains are not desired or required. You may be able to remove them
and allow drainage to flow over the sidewalk in heavy rain events.
Per the discussion on January 30, it was felt that the chase drains would allow for
better drainage.
Number: 50 Created: 1 /28/2008
[1/28/08] With Willow Brook, there was a trail and enhanced mid -block crossing over Big
Dipper near Northern Lights Drive that was designed with the approved plans. This project
will need to construct that mid -block crossing so it must be shown on the plans. I am
providing you with a copy of the crossing from the approved plans as well as the standard
detail. Please show the crossing on your plans and provide the detail in your plan set. I am
assuming that money was escrowed with the City for all of the off -site Big Dipper
improvements and are reimbursable items but you should contact Matt Baker in Street
Oversizing to determine how much was collected for this future construction. Please at least
show the mid block crossing on your plans prior to a public hearing review. There may be
additional street signage requirements for this mid -block crossing which will be determined
at final compliance review.
The mid -block ramps and crosswalk stripping has been added to the plans
Number: 51 Created: 1 /28/2008
[1/28/08] Please provide an intersection detail per LCUASS 7-27 at final compliance for the
intersection of Big Dipper and Strauss Cabin.
Intersection details will be provided upon final compliance.
Number: 52 Created: 1 /28/2008
[1 /28/08] Please provide an intersection detail per LCUASS 7-27 for the intersection of Big
Dipper and Northern Lights to show how the crown transition occurs and to justify granting a
variance for a centerline grade of less than 0.5 percent. Flowline grades must be
maintained at 0.5 percent or more. Where the road has a sump for the inlets, a vertical
curve must be provided to comply with LCUASS 7.4.1.B.4 (c).
Intersection details will be provided upon final compliance. A crown transition has
been designed and will be provided upon final compliance to avoid the need for a
grading variance.
Number: 53 Created: 1 /28/2008
[1/28/081 Check with the water district, I believe they only want the signature block on the
cover sheet of the Utility Plan set. They may not want to sign every sheet. Please confirm
with Mr. DiTullio or Mr. Farrill on this.
The district requires their signature blocks on every sheet of the Utility Plan set.
Number: 54
Created: 1 /28/2008
Page 3
All street cuts occurring in Strauss Cabin Road have been shown.
Number: 43 Created: 1 /28/2008
[1/28/08] The proposed sewer connection on the north side of Lot 2 is outside the property
boundary and will require an off -site easement. This easement may be dedicated by
separate document as labeled on the plans, the on -site portion of that easement may be
dedicated by the Plat ... it's your choice. The City will need a letter of intent to dedicate this
easement from Sunrise Ridge 2nd Filing prior to scheduling a public hearing. If there is an
existing utility easement that encompasses this proposed sewer connection, please show
the easement on the plans and reference where it is recorded.
The District requires all sanitary sewer easements to be recorded by separate
document on the District's standard form.
Number: 44 Created: 1 /28/2008
[1/28/08] Please clearly show and label the existing utility easement for the existing sewer
main that runs from Sunrise Ridge through Willow Brook off -site.
The utility easement has been clearly shown and labeled, the GPS department for the
district will provide us with the reception number and we will add the number to our
plans at final compliance.
Number: 45 Created: 1 /28/2008
[1/28/08] Please correct the driveway labeling for the access to Lot 1 and call it out with
LCUASS Detail 706.
The drive has been corrected and labeled as LCUASS Detail 706.
Number: 46 Created: 1 /28/2008
[1/28/08] The easterly driveway proposed on Big Dipper closest to Strauss Cabin Rd. will
need to be paved to a minimum of 20 feet beyond the property boundary to reduce dirt and
debris track out from this shared driveway access. Please show, dimension and clearly
label this on the plans. Can be concrete of asphalt, beyond that the driveway can be gravel.
The access drive has been modified and dimensioned through call outs
Number: 47 Created: 1 /28/2008
[1/28/08] There are a few areas on the grading plan where proposed grading appears to go
off -site. You will need to either pull back the grading so that it ties into existing grades on -
site or you will need to get temporary construction easements for off -site grading. Any off -
site easements will require letters of intent prior to scheduling a hearing.
The grading has been modified in all location except for within the off -site sanitary
sewer easement. Grading within this easement is needed to provide adequate depth
over the proposed sanitary sewer main.
Number: 48 Created: 1 /28/2008
[1/28/08] Please clearly show and label the existing edge of asphalt on Strauss Cabin Road
and ROW/property boundary limits on all four sides on the Utility and Grading Plans.
The edge of asphalt line type has been thickened and labeled.
Page 2
STAFF PROJECT REVIEW
2= Fort Collins
April Hutchison/Kim Dall Date: 2/5/2008
Northern Engineering
200 South College Ave
Fort Collins, CO 80524
Staff has reviewed your submittal for OLD OAK ESTATES PDP - TYPE I, and we offer the
following comments:
ISSUES:
Department: Engineering Issue Contact: Randy Maizland
Topic: Engineering
Number: 38 Created: 1/28/2008
[1/28/08] Plat — The private drive cannot be a named, improved private drive unless it is
dedicated in a separate tract of land. I am under the assumption this cannot be done
because it will reduce the lot sizes below minimum allowable size. Therefore, the private
drive will need to be a standard driveway access and the properties will need to be
addressed off of Big Dipper Drive with an address kiosk at the driveway entrance for PFA.
The private drive will remain unnamed and a mail kiosk will be placed at the end of the
private drive.
Number: 39 Created: 1 /28/2008
[1/28/08] Plat — No application has been submitted for a proposed ROW vacation of 4.5 feet
along Big Dipper Drive. An application for the vacation and all application/review fees must
be submitted prior to scheduling a public hearing.
All of the right-of-way vacation applications & applicable fees are provided with this
submittal.
Number: 40 Created: 1 /28/2008
[1/28/08] Please insert the Plat into the Utility Plan set for reference as indicated on the
cover sheet Index.
The plat sheets have been added to the Utility Plan set and the note "For Reference
Only" has been added to the cover sheet.
Number: 41 Created: 1 /28/2008
[1/28/08] All construction & standard LCUASS details will be required with the final
compliance submittal.
All details will be provided upon final compliance.
Number: 42 Created: 1 /28/2008
[1/28/08] Please show any proposed street cuts that may be required along Strauss Cabin
Road in order to tie into Big Dipper Drive and make connections to the water main for Lots 5
and 6. Hatch the approximate limits of street cut and reference note 16 on sheet U1. Please
also clearly show and label the existing edge of asphalt on Strauss Cabin Rd.
Puce I