HomeMy WebLinkAboutOLD OAK ESTATES (5227 STRAUSS CABIN RD.) - PDP - 25-07A - CORRESPONDENCE -Department: Stormwater-Water-Wastewater Issue Contact:. Wes Lamarque
Topic: Stormwater
Number: 65 Created: 2/29/2008
[2/29108] It has been discovered that the spillway for the detention pond in
Observatory Village, which this site is connecting to with a storm sewer, is at an
elevation of 4989.5. This elevation is one foot higher than the finish floor elevation
of the existing house within Old Oak Estates. If Observatory Village's detention
pond were to be in a spill condition, the existing house in Old Oak Estates would be
inundated with one foot of water. A solution needs to be worked out to protect the
existing house and other downstream properties or connecting to this pond will not
be feasible.
Number: 66 Created: 2/29/2008
[2/29/08] The 100-year flows for the south half of Big Dipper Drive in sub -basin C
need to be contained within the right-of-way. Please provide calculations supporting
this.
Number: 67 Created: 2/29/2008
[2/29/08] Please provide details in the plan set for all drainage improvements to be
constructed.
Number: 68 Created: 2/29/2008
[2/29/08] Please provide a close-up view of the riprap rundown and a cross-section
detail. The riprap should be buried with 6-inches of topsoil.
Number: 69 Created: 2/29/2008
[2/29/08] Please provide the latest storm sewer calculations and show the HGL on
the profiles.
Comments from Current Planning:
Please see minor corrections to the Site Notes on the Site Plan.
2. Please see minor correction to Note number five on the Plat.
Be sure and return all of your redlined plans when you re -submit. If you have any
questions regarding these issues or any other issues related to this project, please
feel free to call me at (970) 221-6750.
S`innccerely:
/
Ted Shepard
Chief Planner
Page 2
�r
City of Fort Collins
April Hutchinson/Kim Dall
Northern Engineering
200 South College Ave
Fort Collins, CO 80524
STAFF PROJECT REVIEW
Date: 3/4/2008
Staff has reviewed your submittal for OLD OAK ESTATES PDP - TYPE I, and we
offer the following comments:
ISSUES:
Department: Light & Power Issue Contact: Doug Martine
Topic: Electric Utility
Number: 62 Created: 2/19/2008
[2/19/08] This comment is only a 'heads -up', not a condition for approval. After final
approval, please send an AutoCad drawing of the approved plat to Pat Colburn. Her
email address is PCOLBURN@FCGOV.COM. Thanks!
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 22 Created: 10/10/2007
[2/27/08] I'd like to see a proposed location, or at least estimated location, of the
new fire hydrant. Please be aware that the maximum 400=foot distance from hydrant
to structure is not "as the crow flies." The distance is based on the distance
emergency vehicles would travel over the roadway.
[ 1 /30/081
[10/10/07] WATER SUPPLY: Fire hydrants, where required, must be the type
approved by the water district having jurisdiction and the Fire Department. Hydrant
spacing and water flow must meet minimum requirements based on type of
occupancy. Minimum flow and spacing requirements include: residential within
Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further.than
400 feet to the building, on 800-foot centers thereafter. These requirements may be
modified if buildings are equipped with automatic fire sprinkler systems.
97UFC 901.2.2.2
Number: 63 Created: 2/27/2008
[2/27/08] Regarding the applicant's response to comment 38: 1 believe the correct
terminology is an "address kiosk" and not a "mail kiosk." I'm not exactly sure what a
"mail kiosk" is, but if it's just a row of mailboxes, that will not suffice for identifying
structure addresses for emergency use.
Number: 64 Created: 2/27/2008
[2/27/08] Regarding note 5 on the site plan: It states that lots 2, 3, 5 and 6 have
access from Old Oak Estates Lane. Should this be corrected to say that lots 2, 3, 5
and 6 will take access from the private drive?
Page 1