Department: Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number: 1 Created: 4 / 9 / 2008
[4/9/08] No Comments
This completes staff (and outside reviewing agencies) review and comments
at this time. Red -lined plans from City departments are included with this
comment letter. Additional comments and red -lined plans may be
forthcoming. Another round of staff review is determined to be necessary.
This proposal is subject to the 90-day revision re -submittal
requirement (from the date of this comment letter, being April 22,
2008) as set forth in Section 2.2.11(A) of the Land Use Code. Be sure
and return all red -lined plans when you re -submit. The number of copies of
each document to re -submit is shown on the attached Revisions Routing
Sheet. Once re -submitted, the revisions will go through a 2-week round of
review before being discussed at a Wednesday morning staff review meeting.
If you have any questions regarding these issues or any other issues related
to this project, please feel free to call me at 221-6341.
Yours Truly,
40be &w
Steve Olt
City Planner
cc: Susan Joy
J*R Engineering
Current Planning file #9-08
Page 6
.-
•
Number: 3 Created: 4/ 11/2008
[4/ 11 /08] WATER SUPPLY: Fire hydrants, where required, must be the
type approved by the water district having jurisdiction and the Fire
Department. Hydrant spacing and water flow must meet minimum
requirements based on type of occupancy. Minimum flow and spacing
requirements include:
• Commercial, 1,500 gpm at 20 psi residual pressure, spaced not farther
than 300 feet to the building, on 600-foot centers thereafter
• Residential within Urban Growth Area, 1,000 gpm at 20 psi residual
pressure, spaced not farther than 400 feet to the building, on 800-foot
centers thereafter
• Residential outside Urban Growth Area, 500 gpm at 20 psi residual
pressure, spaced not farther than 400 feet to the building, on 800-foot
centers thereafter.
These requirements may be modified if buildings are equipped with
automatic fire sprinkler systems. 97UFC 901.2.2.2
Number: 4 Created: 4/ 11 /2008
[4/ 11/08] ADDRESS NUMERALS: Address numerals shall be visible from
the street fronting the property, and posted with a minimum of 6 inch
numerals on a contrasting background. (Bronze numerals, on brown brick
are not acceptable). 97UFC9O1.4.4
Department: Stormwater-Water-Wastewater Issue
Contact: Wes Lamarque
Topic: Stormwater
Number: 25 Created: 4/ 18/2008
[4/ 18/08] Please provide a note on the grading plan stating that a detailed
lot grading plan for Lot 2 will be required before a building permit can be
pulled on Lot 2. Also, the proposed grading on Lot 2 can be removed with
just the existing grades shown on the plan for now.
Number: 26 Created: 4/ 18/2008
[4/ 18/08] The irrigation ditch owners will need to approve any changes
made to the ditch. Also, suggest investigating all aspects of the ditch
including route, usage, etc.
Number: 27 Created: 4/ 18/2008
[4/ 18/08] Even though detention is not required due to the low impervious
ratio, drainage can not negatively impact downstream property owners. If
additional drainage over existing conditions is being conveyed downstream
onto other properties, a drainage easement may be required from those
property owners. Another option is to design a small detention area that
will reduce the flows to match existing conditions.
Page 5
-i
Number: 22 Created: 4/ 16/2008
[4/ 16/08] Any conflicts between 15' Utility Easement adjacent to Kechter
Road and 20' Ditch Easement need to be resolved before Light & Power can
use the Utility Easement. Fort Collins Light & Power will have to cross the
ditch in the 20' easement adjacent to Kechter Road, as well as the ditch in
the 10' easement to the north of the existing house. Any ditch crossing
issues should be resolved prior to construction by Light & Power.
Number: 23 Created: 4/ 16/2008
[4/ 16/08] There will be no charge to transfer the existing property to Fort
Collins L&P since it is an annexation. The new lot to the north of the
existing property (Lot 2) will be subject to normal development charges.
Number: 24 Created: 4/ 16/2008
[4/ 16/08] If no utility easement can be obtained from Kingdom Hall to the
Thorland Subdivision, L&P will construct the new electric system in the
R.O.W. at no additional cost to the applicant. This may create some
difficulties to transfer power to properties between Kingdom Hall and the
Thorland Subdivision should they be annexed before Kechter Road is
improved, and the acquisition of a utility easement would be preferred.
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 2 Created: 4 / 11 / 2008
[4/ 11/08] REQUIRED ACCESS: Fire access roads (fire lanes) shall be
provided for every facility, building or portion of a building hereafter
constructed or moved into or within the PFA's jurisdiction when any portion
of an exterior wall of the first story of the building is located more than 150
feet from fire apparatus access as measured by an approved route (from a
public street) around the exterior of the building or facility. This fire lane
shall:
❑ Be designed as a flat, hard, all-weather driving surface (asphalt or
concrete) capable of supporting fire apparatus weights. Compacted road
base shall be used only for temporary fire lanes or at construction sites.
❑ Have appropriate maintenance agreements that are legally binding and
enforceable.
❑ Be designated on the plat as an Emergency Access Easement.
❑ Maintain the required minimum width of 20 feet throughout the length
of the fire lane.
A fire lane plan shall be submitted for approval prior to installation.
If a fire lane is not provided, all buildings out of access (exceeding the 150-
foot requirement) shall be equipped with an approved automatic fire -
sprinkler system. 97UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1
Page 4
Number: 18 Created: 4/ 16/2008
[4/ 16/08] Just verifying that the 15' UE easement off Kechter Road is
starting at the back of the ultimate ROW - the plat looks correct but the
dimensioning arrows on sheet 6 of the Utility Plan set start at the existing
row.
Number: 20 Created: 4/ 16/2008
[4/ 16/08] This development is responsible for the design and construction
of Kechter Road along its frontage plus the design and construction of Sage
Creek Road. In lieu of actually designing and constructing these
improvements, engineering is agreeable to obligating the owner of the lots to
the future improvements at such time the road needs to be built and will
place this requirement in the Development Agreement. However, the
sidewalk does need to be installed at the ultimate location, per
Transportation Planning, and Type III barricades installed at either end.
Topic: Plat
Number: 15 Created: 4/ 16/2008
[4/ 16/08] From Technical Services:
1. Boundary closes.
2. Bearing on north line of subdivision does not match Blehm Subdivision
or Thorland Annexation No. 1.
3. See typos "unincorporated" and sheet 2 and LS # for sw corner of
Section 5, sheet 1 and 2.
4. Please add "ties" for access and utility easement along Kechter Road
ROW.
5. The 51' ROW should be "Sage Creek Road".
6. Do we need easements on each side of Sage Creek Road? (Yes, per
Engineering, 9 ue's are required on either side)
Topic: Utility Plans
Number: 19 Created: 4/ 16/2008
[4/ 16/08] Grading - sheet 7: Off -site grading is shown. Please pull the
contours back onto the property or offsite easements will be required.
Department: Light & Power Issue Contact: Justin Fields
Topic: General
Number: 21 Created: 4/ 16/2008
[4/ 16/08] Poudre Valley REA agreed to change current easements to say
'utility easement' instead of 'REA easement.' This may eliminate the need
for a separate Fort Collins Light & Power easement along the eastern
property line. The 30' REA easement intersecting the property from east to
west is not being used by the REA (except for guying an existing pole) and
they are willing forfeit that easement (except for guying as required). Please
contact Terry Willis at Poudre Valley REA for more details (282-6432).
Page 3
Home Owners Associations of private property owner rights to use resource
saving devices or techniques under certain conditions. Said note shall read:
Private Conditions, Covenants, and Restrictions (CC&R's), or any other
private restrictive covenant imposed on landowners within the
development, may not be created or enforced which has the effect of
prohibiting or limiting the installation of xeriscape landscaping,
solar/photo-voltaic collectors (if mounted flush upon any established
roof line), clothes lines (if located in back yards), odor -controlled
compost bins, or which has the effect of requiring that a portion of any
individual lot be planted in turf grass.
Department: Current Planning Issue Contact: Steve Olt
Topic: Subdivision Plat
Number: 10 Created: 4/ 15/2008
[4/ 15/081 The 51' right-of-way (ROW) to be dedicated with this plat must
be named Sage Creek Road. As other properties to the east redevelop or
develop this street could ultimately connect to Sage Creek Road in the Sage
Creek development to the east.
Number: 11 Created: 4/ 15/2008
[4/ 15/08] Can the 15' wide utility easement along the north side of Kechter
Road be within the existing 20' wide ditch easement?
Number: 12 Created: 4/ 15/2008
[4/ 15/081 There is a 10' wide ditch easement running east - west across
the property on the south side of the 30' existing REA easement. The
easement should be labeled 10' existing ditch easement.
Number: 13 Created: 4/ 15/2008
[4/ 15/08] Tim Varrone of the City's Geographical Information Systems
Department indicated that the new lot, the 3.90 acre parcel, will likely
receive a new address of 2230 Kechter Road.
Number: 14 Created: 4/ 15/2008
[4/ 15/08] Gene Fischer, the attorney for the New Mercer Ditch
Company, indicated that a $500.00 review fee must be paid in advance for
storm drainage.
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 16 Created: 4/ 16/2008
[4/ 16/08] 9' utility easements are required either side of Sage Creek Road.
Number: 17 Created: 4/ 16/2008
[4/ 16/08] Please label Sage Creek Road, all plan sets.
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
Miles and Jennifer Thorland Date: 4/22/2008
4918 Bluestem Court
Fort Collins, CO 80525
Staff has reviewed your submittal for THORLAND SUBDIVISION, PROJECT
DEVELOPMENT PLAN (PDP) - TYPE 1, and we offer the following
comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: General
Number: 5 Created: 4/ 15/2008
[4/ 15/08] The applicants have submitted a subdivision plat and utility
plans. Are there plans for the required Kechter Road street design?
Number: 6 Created: 4/ 15/2008
[4/ 15/08] Several of the sheets in the utility plan set should be signed by
the City's Environmental Planner. Please see the red -lined plans.
Number: 7 Created: 4/ 15/2008
[4/ 15/08] On Sheet 5 of 8 - Existing Conditions and Demolition Plan,
please remove the internal solid lines that represent the annexation
boundary between the Thorland No. 1 and Thorland No. 2 Annexations.
They are not relevant to this plan.
Number: 8 Created: 4/ 15/2008
[4/ 15/08] On Sheet 6 of 8 - Horizontal Control and Overall Utility Plan, the
word "field" is misspelled in the label for the future leaching field.
Number: 9 Created: 4/ 15/2008
[4/ 15/08] On Sheet 7 of 8 - Grading and Drainage Plan, it appears that
there will be some storm water flows that will leave this property and go
onto Lot 2, to the east. Will that property owner have to grant a drainage
easement on their property for these flows?
Department: Current Planning Issue Contact: Dana Leavitt
Topic: Plat
Number: 28 Created: 4 / 22 / 2008
[4/22/081 In order to, promote compliance with Sections 12-120, 12-121
and 12-122 of the City Code related to Resource Conservation, a note must
be placed on the PDP Site Plan (when one is submitted, probably with a
Building Permit application) and the Subdivision Plat (now) alerting future