HomeMy WebLinkAboutPOUDRE VALLEY PLAZA WTF (AT&T) - PDP - 6-09 - CORRESPONDENCE -w 1 4
lines (based on field locates) to the site plan and maintain 10 feet of separation between the
proposed facilities (including the underground electrical service) and the water/sewer lines
(including the water services extending south of the water main).
Department: Zoning Issue Contact: Jenny Nuckols
Topic: zoning
Number: 1 Created: 2/3/2009
[2/3/09] No comments.
This development request has been scheduled for an Administrative Public Hearing in front
of a City -assigned Hearing Officer on Thursday evening, March 5, 2009. The comments
expressed in this letter can be addressed with the required Final Plan submittal after the
public hearing. Be sure and return all red -lined plans when you submit the Final Plans for
review.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970)221-6341.
Yours Truly,
*Steve
Olt
City Planner
cc: Sheri Langenberger
Fred Croci
Current Planning file #6-09
Page 3
Department: Engineering Issue Contact: Sheri Langenberger
Topic: zoning
Number: 2 Created: 2/3/2009
[2/3/09] A drainage easement exists where the building is desired to be placed. A structure
can not be placed within an easement. In order for the building to be placed as shown the
area underneath the building will need to be vacated.
I would suggest checking with Stormwater to determine if a portion of the easement can be
vacated before submitting a request to do so. Engineering charges a $400 processing fee for
vacating an easement. The applicant is responsible for providing a legal description (which
is required to be prepared by a licensed surveyor) and the fees for filing fees. Please contact
Sheri Langenberger at 221-6605 for an informational sheet on the vacation process.
Department: Light & Power Issue Contact: Alan Rutz
Topic: zoning
Number: 3 Created: 2/ 17/2009
[2/17/09] Existing transformer is 120/208 volt three phase.
Number: 4 Created: 2/17/2009
[2/17/09] Electric meter must be placed on the outside of the enclosure
Number: 5 Created: 2/ 17/2009
[2/17/09] Contact Light and Power with load requirements and billing data.
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 9 Created: 2/19/2009
PFA has no comments or concerns at this time.
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Stormwater
Number: 7 Created: 2/19/2009
[2/19/09] The blanket drainage easement will need to be vacated for the limits of the
structure.
Number: 8 Created: 2/19/2009
[2/19/09] Drainage currently sheet flows through this area to the northeast. Drainage should
be diverted around this structure. This can be done with curb & gutter. Please show on the
site plan how drainage will be directed around the structure.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington.
Topic: Water/Wastewater
Number: 6 Created: 2/18/2009
[2/18/09] There are existing water/sewer lines in the drive adjacent to the proposed
building/tower site. The water line extends east to Centennial. Add the location of these
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
TerraTecTonics, for AT&T Mobility Date: 2/20/2009
c/o Mike Matzko
P.O. Box 3600
Avon, CO 81620
Staff has reviewed your submittal for Poudre Valley Plaza / AT&T Wireless
Telecommunication Facility (WTF), Project Development Plan (PDP) - Type 1, and we
offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Genera[
Number: 10 Created: 2/20/2009
[2/20/09] Please revise the Landscape & Elevations Plans to show the existing trees and
shrubs in the island at the west end of this facility.
Number: 11 Created: 2/20/2009
[2/20/09] Please add West to Horsetooth Road on the Site Plan for the entire Poudre Valley
Plaza center. Please label Century Drive, along the east side of the center, on the same Site
Plan.
Number: 12 Created: 2/20/2009
[2/20/09] Please put "Poudre Valley Plaza" in the middle of the center on the overall Site
Plan.
Number: 13 Created: 2/20/2009
[2/20/091 Rick Lee of the Building Department is forwarding to the applicant a copy of the
2008 Commercial / Multi -Family Codes & Standards that will apply to this development
request.
Number: 14 Created: 2/20/2009
[2/20/09] Technical Services indicated that a portion of the Title Block is missing on the
11" x 17" drawings. Also, the legal description for the Poudre Valley Plaza center, and
possibly the portion of the center where this WTF will be located, must be added to the
Overall Site Plan.
Number: 15 Created: 2/20/2009
[2/20/09] Signature blocks for the Owner's Certification, a Notary Public (to notarize the
owner's signature), and the Director of Planning must be added to the overall Site Plan.
Page 1