HomeMy WebLinkAboutPOUDRE SCHOOL DISTRICT, EAST PROSPECT ROAD SERVICE FACILITY - ODP - 44-08 - CORRESPONDENCE -[12/31/08] The Land Use Data table on the cover sheet lists Parcels A, B and C. Sheet 2 of 3 shows Parcels A, B and D. Is "D" on this sheet supposed to be "C"? And if so, isn't "C" in the I zone? The Land Use Data table lists the parcels and the "permitted uses in Urban Estate". If "C" is in the I, then the table needs to be revised. Also, shouldn't the permitted uses column on the table show the "proposed" uses instead of the "permitted" uses. Additionally, the permitted UE uses listed include uses which aren't permitted in the UE zone (i.e. office and warehouse). I understand that they will pursue "an addition of permitted use" application, but until such time as that's approved, assuming that it might be, I don't think the uses should be listed at this time on the ODP plan. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Ted Shepard City Planner Page 5 Number: 20 Created: 1 /15/2009 HAZARDOUS MATERIALS Toxic, corrosive, or reactive materials, or flammable/combustible liquids (as defined in the Uniform Fire Code) if used, stored, or handled on site, must have a Hazardous Materials Impact Analysis (HMIA) completed and supplied to the Planning Department and the Fire Department. (What do you have? How much? How do you prevent it from being a public threat?) FCLUC 3.4.5 Number: 21 Created: 1 /15/2009 FUELING STATION Permits are required from PFA to install fueling systems. Two sets of plans shall be provided to PFA for review; these cut sheets shall show the number, size, contents and construction of the fuel tanks and their assemblies. Number: 22 Created: 1 /15/2009 ACCESS POINTS At least two vehicular access points to the site shall be provided. Number: 23 Created: 1 /15/2009 STORAGE/MAINTENANCE What type of storage will be in the warehouse? What type of operations (maintenance) will be conducted in the transportation facility? Will there be motor -vehicle repair? Welding? Please contact me with the answers. Number: 24 Created: 1 /15/2009 IDENTIFICATION OF FIRE PROTECTION EQUIPMENT Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, electrical rooms, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. 2006 International Fire Code 510.1 Department: Traffic Operations Issue Contact: Joe Olson Topic: Engineering Number: 10 Created: 1 /14/2009 Based on feedback at a neighborhood meeting a trip generation study for the existing PSD facility on LaPorte Avenue during the a.m. and p.m. peak hours should be conducted to verify the trip generation assumptions in the TIS. This study should be documented in the TIS and the study should be updated if higher trip generation estimates are warranted. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Fire Number: 25 Created: 1 /16/2009 [1/16/09] No comments for the ODP. Just a reminder that Ditch owner approval will be required during PDP review before a public hearing can be scheduled. The Ditch owner will have to approve the release from the ponds into their ditch and provide any necessary drainage easements for the conveyance from the ponds to the ditch. Department: Zoning Topic: Zoning Number: 4 Issue Contact: Peter Barnes Created: 12/31 /2008 Page 4 Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be installed in the following locations: 1. New buildings greater than 50,000 SF in size or addition(s) to an existing building that cause the building to be greater than 50,000 SF. For the purpose of this section, fire walls shall not be used to define separate buildings. 2. All new basements greater than 10,000 SF where the designed occupant load is greater than 50, regardless of the occupancy classification. 3. Existing buildings meeting the criteria of Items 1 and 2 of this section undergoing alterations exceeding 50 percent of the aggregate area of the building. Public -safety radio amplification systems shall be designed and installed in accordance with criteria established by Poudre Fire Authority. PFA Fire Prevention Bureau Administrative Policy 07-01. Number: 15 Created: 1 /15/2009 WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B. Number: 16 Created: 1 /15/2009 AUTOMATIC FIRE SPRINKLERS The addition shall be equipped with an approved automatic fire -sprinkler system. Number: 17 Created: 1/15/2009 FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed in an approved location, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2 and PFA Fire Prevention Bureau Number: 18 Created: 1 /15/2009 KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box') to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 Number: 19 Created: 1 /15/2009 FIRE LINE REQUIREMENT Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. NFPA 13 (2007) 23.1.3 Page 3 transformers, and a plat (or other drawing) showing the perimeter dimensions of the site. Given the VERY PRELIMINARY information available, these fees are estimated to be in the $750,000 range. Topic: Utility Plan Number: 2 Created: 12/29/2008 112/29/08] The developer will need to coordinate the installation, including depth, of the power facilities to be incorporated with the box culvert(s). This may be complicated by the depth of power line crossing the adjacent Greeley water transmission line. Number: 3 Created: 12/29/2008 [12/29/08] The developer will need to coordinate transformer location(s) with Light & Power Engineering (221-6700). It is encouraged that this coordination occur well prior to finalizing the utility and site plans. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 11 Created: 1 /15/2009 REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is Iodated more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: ❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ❑ Have appropriate maintenance agreements that are legally binding and enforceable. ❑ Be designated on the plat as an Emergency Access Easement. ❑ Maintain the required minimum width of 20 feet throughout the length of the fire lane. If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3 503.3, 503.4 and Appendix D Number: 12 Created: 1 /15/2009 ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 2006 International Fire Code 505.1 Number: 13 Created: 1 /15/2009 TURNING RADII The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 503.2.4 and Appendix D103.3 Number: 14 Created: 1 /15/2009 PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM Page 2 STAFF PROJECT REVIEW City of Port Collins BHA Design Inc Date: 01/29/2009 Cara Scohy 1603 Oakridge Dr Fort Collins CO 80525 Staff has reviewed your submittal for Poudre School District/Larimer County Joint Service Facility ODP, and we offer the follAwing comments: ISSUES: Department: Current Planning Issue Contact: Dana Leavitt Topic: General Number: 9 Created: 1 /8/2009 [1/8/09] All development shall comply with Section 3.4.1- natural habitats and Features, of the Land Use Code. Department: Engineering Issue Contact: Randy Maizland Topic: Engineering Number: 5 Created: 1 /8/2009 [1/8/09] The plan does not match the description of the proposed access addressed in the T.I.S. related to lining up with McLaughlin. The T.I.S. will need to be updated to address the access point as shown on the plan. See redlines for clarification. It appears that this alternate access location does meet minimum separation standards. Widening improvements will need to be determined for Phase I based on the traffic impacts. Additional widening and improvements may be requested with Phase I beyond just widening for an eastbound left tune lane on Prospect. Number: 6 Created: 1 /8/2009 [1/8/09] If the proposed access on the far west boundary off of Prospect is intended to serve a connection that crosses the site and extends to the north boundary, this connection will most likely need to be a dedicated public ROW. Please clarify the intended need for this access. Private drives are appropriate for roads that only serve the site and do not provide through connections to other developable property that may take access to this connection. Topic: Technical Services Number: 7 Created: 1 /8/2009 [1/8/09] The Vicinity Map should be revised to use a one line street map with no shading. The existing map will not scan or copy well. Number: 8 Created: 1 /8/2009 [1/8/09] The legal description text on the cover sheet is blurry and will not scan well. Please provide clear text. See redlines for clarification on scannability issues. Department: Light & Power Issue Contac:b Doug Martine Topic: Electric Fees Number: 1 Created: 12/29/2008 [12/29/08] Contrary to the response to a Conceptual Review comment, the Light & Power Electric Development Fees do apply to the school district. In order to determine these charges, Light & Power Engineering will need electric load information, locations of Page 1