Loading...
HomeMy WebLinkAboutPOUDRE SCHOOL DISTRICT, EAST PROSPECT ROAD SERVICE FACILITY - ODP - 44-08 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTDETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method Pond C 100-Year Event LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: es DATE: 12/23/2008 Equations: Area trib. to pond = Developed flow = Qo = CIA C (100) = Vol. In = Vi = T C I A = T Qp Developed C A = Vol. Out = Vo =K QPo T Release rate, QPo = storage = S = Vi - Vo K = Rainfall intensity from City of Fort Collins OF Curve with (3.67") rainfall 3.6 acre 0.91 3.3 acre 0.70 cfs 1.0 (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, I (in/hr) Qp (cfs) Vol. In Vi (ft) Vol. Out Vo (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 32.6 9779 210 9569 0.22 10 7.72 25.3 15174 420 14754 0.34 20 5.60 18.3 22015 840 21175 0.49 30 4.52 14.8 26654 1260 25394 0.58 40 3.74 12.3 29405 1680 27725 0.64 50 3.23 10.6 31744 2100 29644 0.68 60 2.86 9.4 33730 2520 31210 0.72 70 2.60 8.5 35774 2940 32834 0.75 80 2.34 7.7 36796 3360 33436 0.77 90 2.17 7.1 38388 3780 34608 0.79 100 1.99 6.5 39115 4200 34915 0.80 110 1.87 6.1 40432 4620 35812 0.82 120 1.75 5.7 41278 5040 36238 0.83 130 1.66 5.4 42418 5460 36958 0.85 140 1.57 5.1 43204 5880 37324 0.86 150 1.48 4.8 43636 6300 37336 0.86 160 1.42 4.7 44658 6720 37938 0.87 170 1.36 4.5 45445 7140 38305 0.88 180 1.29 4.2 45641 7560 38081 0.87 Required Storage Volume: 38305 ft3 0.88 acre-ft Detention Pond D.xls,FAA-100yr Design -Procedure Form: Extended Detention Basin (EDB) Sedlmentatlon_Faclllty_4-' Designer: ES Company: Interwest Consulting Group Date: December 23, 2008 Project: PSD Location: Basin C 1. Basin Storage Volume A) Tributary Area's Imperviousness Ratio (i = 1,/ 100 ) B) Contributing Watershed Area (Area) C) Water Quality Capture Volume (WQCV) (WQCV =1.0' (0.91 " 13 - 1.19 " Iz + 0.78' 1)) D) Design Volume: Vol = (WQCV / 12)' Area' 1.2 2. Outlet Works A) Outlet Type (Check One) B) Depth at Outlet Above Lowest Perforation (H) C) Recommended Maximum Outlet Area per Row, (A,) D) Perforation Dimensions: i) Circular Perforation Diameter or ii) Width of 2" High Rectangular Perforations E) Number of Columns (nc, See Table 6a-1 For Maximum) F) Actual Design Outlet Area per Row (N) G) Number of Rows (nr) H) Total Outlet Area (A,J 3. Trash Rack A) Needed Open Area: A, = 0.5' (Figure 7 Value)' A, B) Type of Outlet Opening (Check One) C) For 2", or Smaller, Round Opening (Ref.: Figure 6a): I) Width of Trash Rack and Concrete Opening (W..) from Table 6a-1 ii) Height of Trash Rack Screen (HT) la = 70.00 % Area = 3.600 acres WQCV = 0watershed inches Vol '0 0990-?Wacre-feet e X Orifice Plate Perforated Riser Pipe Other. H = 0.00 feet Ao F7F~ l 7V-'2,i square inches D = Pa"e�`-^-;-i250 inches W = Wz&?V�%W inches nc =,r1F number �)squareinches nr i==0�1° 'r�) number Age = Ef:00'- square inches ' f. ,�,Ta..' Ai t"�, , <_0 . �s,., squareinches 2" Diameter Round High Rectangular Other: W.., ,.`,<0 "(; ...s inches Hra inches Sheet 1 of 3 ' UD-BMP_v2.06 Pond D.xls, EDB 12/23/2008, 11:41 AM DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method Pond B 100-Year Event LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: es DATE: 12/23/2008 Equations: Area trib. to pond = Developed flow = Qo = CIA C (100) = Vol. In = Vi = T C I A = T Qp Developed C A = Vol. Out = Vo =K QPo T Release rate, QPo = storage = S = Vi - Vo K = Rainfall intensity from City of Fort Collins OF Curve with (3.67') rainfall 51 acre 0.91 46.4 acre 10.20 cfs 1.0 (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, I (in/hr) Qp (cfs) Vol. In Vi (ft) Vol. Out Vo (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 461.8 138534 3060 135474 3.11 10 7.72 358.3 214971 6120 208851 4.79 20 5.60 259.9 311875 12240 299635 1 6.88 30 4.52 209.8 377592 18360 359232 8.25 40 3.74 173.6 416576 24480 392096 9.00 50 3.23 149.9 449713 30600 419113 9.62 60 2.86 132.7 477837 36720 441117 10.13 70 2.60 120.7 506797 .42840 463957 10.65 80 2.34 108.6 521277 48960 472317 10.84 90 2.17 100.7 543832 55080 488752 11.22 100 1.99 92.4 554135 61200 492935 11.32 110 1.87 86.8 572792 67320 505472 11.60 120 1.75 81.2 584766 73440 511326 11.74 130 1.66 77.0 600917 79560 521357 11.97 140 1.57 72.9 612055 85680 526375 12.08 150 1.48 68.7 618181 91800 526381W12.08160 1.42 65.9 632661 97920 534741170 1.36 63.1 643800 104040 539760180 1.29 59.9 646584 110160 536424 r equired Storage Volume: 539760 ft3 12.39 acre-ft Detention Pond B-C.xls,FAA-100yr ' Desi ri Procediire Form: Extended Detention Basln EDB 9 ( ) Sedimentation Facilit � h Y ' Designer: ES Sheet 1 of 3 Company: Interwest Consulting Group Date: December 23, 2008 ' Project: PSD Location: Basin B [I [1 1. Basin Storage Volume la = 70.00 % A) Tributary Area's Imperviousness Ratio (i = la / 100) i 0. 70M B) Contributing Watershed Area (Area) Area = 51.000 acres C) Water Quality Capture Volume (WOCV) WOCVOt28.')17watershed inches (W OCV = .19 12) 111 .ol Volume: * Area D) Design Volume: Vol = (W OCV / 12)' Area ' 1.2 (W CV Vol e 1sA(2�7,1] acre-feet 2. Outlet Works A) Outlet Type (Check One) X Orifice Plate ' Perforated Riser Pipe Other. B) Depth at Outlet Above Lowest Perforation (H) H = 0.00 feet C) Recommended Maximum Outlet Area per Row, (Aa) A. = square inches D) Perforation Dimensions: _ i) Circular Perforation Diameter or D ''d inches ii) Width of 2" High Rectangular Perforations W='s'AT.89inches E) Number of Columns (nc, See Table 6a-1 For Maximum) nc a:;=,j 1^'!?' number F) Actual Design Outlet Area per Row (Aa) Aa = ��=15 8 square inches G) Number of Rows (nr) nr = EMT 700—! 77 number H) Total Outlet Area (Aa) Am0 0* r, square inches 3. Trash Rack A) Needed Open Area: A, = 0.5' (Figure 7 Value)Aa, A, 07e�"-_- square inches B) Type of Outlet Opening (Check One) ' t`.-Y. _ S 2' Diameter Round ' W a-,,X1: F„T; 2" High Rectangular Other. C) For 2", or Smaller, Round Opening (Ref.: Figure 6a): i) Width of Trash Rack and Concrete Opening (W..) from Table 6a-1 Wiz ` x%t 4"?-2 inches ii) Height of Trash Rack Screen (HTR) HTR m= �4inches ' UD-BMP_v2.06 Pond B-C.xls, EDB 12/23/2008, 11:47 AM DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method Pond A 100-Year Event LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: es DATE: 12/23/2008 Equations: Area trib. to pond = Developed flow = Qp = CIA C (100) = Vol. In = Vi = T C I A = T Qp Developed C A = Vol. Out = Vo =K QPo T Release rate, QPo = storage=S=Vi -Vo K= Rainfall intensity from City of Fort Collins IDF Curve with (3.67") rainfall 34 acre 0.63 21.4 acre 6.80 cfs 1.0 (from fig 2.1) Storm Duration, T (min) Rainfall Intensity, I (in/hr) Qo (cfs) Vol. In Vi (ft) Vol. Out 'Vo (ft) Storage S (ft) Storage S (ac-ft) 5 9.95 213.1 63939 2040 61899 1.42 10 7.72 165.4 99217 4080 95137 2.18 20 5.60 120.0 143942 8160 135782 3.12 30 4.52 96.8 174273 12240 162033 3.72 40 3.74 80.1 192266 16320 175946 4.04 50 3.23 69.2 207560 20400 187160 4.30 60 2.86 61.3 220540 24480 196060 4.50 70 2.60 55.7 233906 28560 205346 4.71 80 2.34 50.1 240589 32640 207949 4.77 90 2.17 46.5 251000 36720 214280 4.92 100 1.99 42.6 255755 40800 214955 4.93 110 1.87 40.1 264366 44880 21.9486 5.04 120 1.75 37.5 269892 48960 220932 5.07 130 1.66 35.6 277346 53040 224306 5.15 140 1.57 33.6 282487 57120 225367 5.17 150 1.48 31.7 285314 61200 224114W*5.1160 1.42 30.4 291997 65280 226717170 1.36 29.1 297138 69360 227778180 1.29 27.6 298423 73440 224983 Required Storage Volume: 227778 ft3 5.23 acre-ft Detention Pond A.xls,FAA-100yr I r LL Deslg Y, _io dure Form _Extended DetenUonlBasm (EDB)_ Sedimentation Faculty _. r N Sheet 1 of 3 Designer: ES Company: Interwest Consulting Group Date: December 23, 2008 Project: PSD Location: Basin A 1. Basin Storage Volume I, = 40.00 % A) Tributary Area's Imperviousness Ratio (i = I,/ 100) B) Contributing Watershed Area (Area) Area = 34.000 acres C) Water Quality Capture Volume (WQCV) . WQCV=ERTTA8 F1watershed inches (WQCV =1.0' (0.91h- 1.19' IZ+0.78' M D) Design Volume: Vol 1.2 Vol =,ate 0:6115,;. acre-feet �- = (WQCV / 12)' Area' 2. Outlet Works A) Outlet Type (Check One) X Orifice Plate Perforated Riser Pipe Other: B) Depth at Outlet Above Lowest Perforation (H) H = 0.00 feet C) Recommended Maximum Outlet Area per Row, (AJ A. = 7,6.9 51' square inches D) Perforation Dimensions: i) Circular Perforation Diameter or D ,u inches it) Width of 2" High Rectangular Perforations Winches E) Number of Columns (nc, See Table 6a-1 For Maximum) nc number F Actual Design Outlet Area per Row r,m6:9`"w=A s uare inches G) Number of Rows (nr) nr =+i0 �t` number H) Total Outlet Area (k,) Fyi = ? >t:(0:0�?;:°,; ';- square inches 3. Trash Rack A) Needed Open Area: At = 0.5' (Figure 7 Value)' A,, Ar t .:. 0` s square inches B) Type of Outlet Opening (Check One) < 2 Diameter Round >X^.; 2" High Rectangular Other: C) For 2", or Smaller, Round Opening (Ref.: Figure 6a): i) Width of Trash Rack and Concrete Opening (W..) from Table 6a-1 Wmm «ai� `;`y; inches ii) Height of Trash Rack Screen (Hm) HTa =2v=dinches ' UD-BMP v2.06 Pond A.xls, EDB 12/23/2008, 11:40 AM Interwest Consulting Group 1218 West Ash, Suite C Windsor, Colorado RATIONAL METHOD PEAK RUNOFF (100-YEAR) LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: ES DATE: 12/23/2008 100-yr storm, Cf = 1.25 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Des. Point Area Design. A (ac) C Cf tc (min) i (new) (in/hr) Q (100) (cfs) from Design Point Q (100) (cfs) Q(100)tot (cfs) A A 34.00 0.63 17.4 6.05 128.5 128.5 B B 51.00 0.91 17.6 6.00 277.3 277.3 C C 3.60 0.91 7.7 8.55 27.9 27.9 Q=CiA Q = peak discharge (cfs) C = runoff coefficient I = rainfall intensity (in/hr) from IDF curve A = drainage area (acres) NOTE: Intensity based on Figure 3-1, 1999 (Regional Analysis) Flow.xls Q100 Interwest Consulting Group 1218 West Ash, Suite C Windsor, Colorado RATIONAL METHOD PEAK RUNOFF (10-YEAR) LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: ES DATE: 12/23/2008 10-yr storm, Cf = 1.00 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Design . Point Tributary Sub -basin A (ac) C Cf tc (min) i (new) (in/hr) Q (10) (cfs) from Design Point Q (10) (Cfs) Q(10)tot (cfs) A A 34.00 0.50 17.4 2.96 50.3 50.3 B B 51.00 0.73 17.6 2.94 108.6 108.6 C C 3.60 0.73 11.8 3.54 9.31 9.3 Q=CfCiA Q = peak discharge (cfs) C = runoff coefficient Cf = frequency adjustment factor I = rainfall intensity (in/hr) from IDF curve A = drainage area (acres) NOTE: Intensity based on Figure 3-1, 1999 (Regional Analysis) Flow.xls Q10 Interwest Consulting Group 1218 West Ash, Suite C Windsor, Colorado STANDARD FORM SF-2 TIME OF CONCENTRATION -100 YR LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: ES DATE: 12/23/2008 100-yr storm CIF = 1.25 SUB -BASIN DATA INITIAL /OVERLAND TIME (t0 TRAVEL TIME / GUTTER OR CHANNEL FLOW (tt) tc CHECK (URBANIZED BASIN) FINAL tc REMARKS DESIGN POINT SUBBASIN(s) (1) Area (ac) (2) C (3) C'Cf Length (ft) (4) Slope (%) - (5) ti (min) (6) Length (ft) (7) Slope (%) (8) n Manning rough. Val. (Ills) (9) ft (min) (10) tc = 5+it (11) Total (ft) (12) tc=(p180)+10 (min) (13) (min) (14) A A 34.00 0.50 0.63 300 0.5 18.7 1025 0.50 0.013 1.7 9.77 28.4 1325 17.4 17.4 B B 51.00 0.73 0.91 300 0.5 7.6 1075 0.50 0.013 1.7 10.25 17.9 1375 17.6 17.6 D C 3.60 0.73 0.91 100 0.5 4.4 350 0.50 0.013 1.7 3.34 7.7 450 12.5 7.7 EQUATIONS: tc=ti+tt ti = [1.87 (1.1 - CCt) L05 S It3 it = L/Vel. Velocity from Manning's Equation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves Flow.xls TOC-100 Internest Consulting Group 1218 West Ash, Suite C Windsor, Colorado STANDARD FORM SF-2 TIME OF CONCENTRATION -10 YEAR LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: ES DATE: 12/23/2008 10-yr storm Cf = 1.00 SUB -BASIN DATA INITIAL /OVERLAND TIME (ti) TRAVEL TIME / GUTTER OR CHANNEL FLOW (tt) tc CHECK (URBANIZED BASIN) FINAL tc REMARKS DESIGN POINT SUBBASIN(s) (1) Area (ac) (2) C (3) Length (11) (4) Slope (%) (5) 8 (min) (6) Length (R) (7) Slope (%) (8) n Manning rough. Vel. (f/s) (9) tt (min) (10) tc = tl+tt (11) Total L 00 (12) tc=(I/180)+10 (min) (13) (min) (14) A A 34.00 0.50 300 0.5 23.6 1025 0.5 0.013 1.7 9.8 33.3 1325 17.4 17.4 B B 51.00 0.73 300 0.5 14.7 1075 0.5 0.035 0.6 27.6 42.3 1375 17.6 17.6 C C 3.601 0.73 100 0.5 8.5 350 0.5 0.013 1.7 3.3 11.8 450 12.51 11.8 EQUATIONS: tc; =ti+tt ti=[1.87(1.1-CCI)L05]/St1' tt = L/Vel. Velocity from Manning's Equation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + It and urbanized basin check min. tc = 5 min. due to limits of IDF curves Flow.xls TOC-10 Inlerwesl Consulting Group 1218 West Ash, Suite C Windsor, Colorado RUNOFF COEFFICIENTS & % IMPERVIOUS LOCATION: PSD PROJECT NO: 1099-048-00 COMPUTATIONS BY: ES DATE: 12/23/2008 Recommended Runoff Coefficients from Table 3-3 of City of Fort Collins Design Criteria Recommended % Impervious from Urban Storm Drainage Criteria Manual Streets, parking lots (asphalt) Concrete Roofs Gravel Lawns (flat <2%, heavy soil) Runoff coefficient C % Impervious 0.95 100 0.95 96 0.95 90 0.50 40 0.20 1 0 SUBBASIN DESIGNATION TOTAL AREA (ac.) TOTAL AREA (sq.ft) HARD SURFACE AREA (sq.ft) CONCRETE AREA (sq.ft) ROOF AREA (sq.ft) GRAVEL AREA (sq.it) LANDSCAPE AREA (sq.ft) RUNOFF COEFF. (C) % Impervious REMARKS A 34 1,481,040 592,416 0 0 0 888,624 0.50 40 B 51 2,221,560 1.555,092 0 0 0 666,468 0.73 70 C 3.60 156,816 109,771 0 0 0 47,045 0.73 70 Total 88.60 3,859,416 2,257,279 0 0 0 1,602,137 1 0.64 58 Eauations - Calculated C coefficients & % Impervious are area weighted C=E(Ci Ai) /At Ci = runoff coefficient for specific area, Ai At = areas of surface with runoff coefficient of Ci n = number of different surfaces to consider At = total area over which C is applicable; the sum of all Ai's Flow.>ds Cval 1 I 1 t 1] 1 I .NOTES: 1. APPROXIMATE ACCESS. WATER AND SEWER CONNECTIONPOINTSARE SHOWN ON THIS PLAN. THE — — — _ — — — — — — — — — — _ — ROU-nNGTHRWGti HESITEWILLBEDE RMINMD SPECIFICPROJECTSAREBRMGW FORWARD. ALL — — — , m� ACCESS WILL BE THROUGH MWATE DRIVES OR"LOCAV CITY STREETS. UTILITY ROUTES WILL BE IN THESE -- _ _ IS M To M—K/rCH�L WAY—'/ — M TRANSPORT'ATIONCORRIOORSORINUi1L EASEMENTSTHATMEACCESSIBLEBYTHEUPIfTY _ _ + w COMPANIES. --- _ y 2. ASTHESITEDEVELOPS.PROSPECTROADANDLCRS WILL ULTMATELYBEWIOENEDTO4 ANEARTERIAL STREETS. AS PROSPECT IS WIDENED, THE DITCH WILL BE RELOCATED APPROXIMATELY W NORTH OF US !I I I I I I I y PRESENTLOCATION. THEPH INGOFTHESEIMPROVEMENTSWI MOETERMINMD SPECIFIC I MAI001®�!]I I I I I I I LOTY PROJECTS ARE BROUGHT FORWARD. l.E yLL uwi�RLY 3. ALL STORM DETENTION PONDS ARE PRESENTLY DESIGNED TO DISCHARGE TO THE CACHE LA FOUDRE \ I I Al1E INLET DITCH AT 2-YEAR HISTORIC RATES THE ULTIMATE RATE WILL BE DETERMINED WITH THE DUCH I I I I I I COMPANY). THE DUCH COMPANY HAS STATED THAT THEY WILL ACCEPT STORMWATER TO THE DUCH. MIS LINELYTHAT"INTERIM" DETENTION MEASURES MAY BE BUILT IN THE INITIAL PHASES OF DEVELOPMENT. \ rI ICI I III I IiI I el 4. THERE ARE NO FLOODPLAINS ON THIS SITE. THERE IS NO EROSION BUFFER LIMIT ON THIS SITE. S. NONE OF THE EXISTING AR G STRUCTURES E PROPOSED TO REMAIN AFTER THE DEVELOPMENT OF THIS Ste' KrTCHE" —DIVISION 7bTCHELL SRrBO/Y/SrON CWSuBrmu 1\ CWSUBrAUBT I l\ d 5[yER rLL u/YA1D. I OosA:T m A I III OR STE Atmis I i II II III LOTS I I LOTS LOT7 LOTS Lor5 III LOT4 LOT3 I I 11 I III I I I J I\ �I m' umry Eair]!I/T ` � aTOERRY FESB III � I \ xlBvluY AVO CWsusrT7EAvr I / �Fwmnrr I \ �rwmnir RJID T MF1Nae( rLL B 4 / \ m' uB/IY AYl GP4AR2lAY.f), i � I /y \ E LIXX STME1s I_ `j A1F JI — — — / A0.FR \ — mr �/ \ IS ✓� NE,.IfM w . OTHat LOOPW amADOUS 1\ \ II �aa\ l - <SBI , NETAGAN A. 011401 LAGL Sl1EEl6 M \ \ \ SIDES Tu aNNrsr \ \ _ \ \ \ E � SAN A ; ,SITER \ _ ENSIN9 YAN�CT 1 / / \ `D •� m EnSiNa NIwI T fi r\ \\ AND ZY QMr\ t Nsnm THMXIOI 9TE ' —, \ NMTm TNPIXIOI \ e• wtER I \ ' \ \ \ \ pF.vrr rnMl�c � PIE ISRft�TR) AvnRar L sE LOr 5A1I�1R I \ NOR TN As rnawEc — \ a � � \ DETENnON aiNOATIRW _ AREA A S).S' ON AREA B 1. _ Tat aM — — — i \y \ s s S s , s s ��� Ir s s'w3r Ba6P S4rawrs s s DETENTION 7010XE2 6ABNEST I KO WA �PANOO --06 BEFE/ I I , i ' C217( Lorl TINIAN D r LOSTA]Es ^3 HOA�81FoK HwcNOEA®MRO %RmI EoHaN3O 0.3EBTA77B ZOLO2 aS I AP Lor3l DRAINAGE SUMMARY TABLE BASIN IT DETENTION AREA AREA (ACRES) DEV. C (10) I WV. C (100) I DU. 0 (10) (CFS) I OEV. 0 000) (CFS) I RELEASE RATE (CFS) I WO VOLUME (AC -FT) DETENTION VOLUME (AC -FT) A 34 0.50 0.63 1 50 1 129 1 6.8 I0.6 5.2 B 51 1 0.75 1 0.91 1 109 1 277 1 10.2 11.4 12.4 C 3.6 1 0.75 1 0.91 1 9 1 28 1 0.7 1 0.1 1 0.9 HOAEE37£AO ESTAMS LOT 79 i LOT) ODP OVERALL UTILITY AND DRAINAGE PLAN 120 60 O 120 240 BDA`E -120' POUDRE SCHOOL DISTRICT WAREHOUSE E. PROSPECT RD. AND COUNTY ROAD 5 FORT CC3LLlIVS, COLORA�O Rl! W.M SURc BY.A DESIGN, INC. • I.OAK .I NONE 4w R. COLLNUS. CO 111 • TL I9MI 223.7571 N4K v.. SRUS R. RI VR fupGoI A1.Vf p x IlR�eeT CONSULTING GROUP S H E E T 3 of 3 DECEMBER 24, 2008 r- c� SITE N Cn i PROSPECT FFIR- VICINITY MAP N.T.S. l I I I I l I I I I 1. 11 I LIU MIMM City of Fort Collins OOP Drainage Report for Page 5 ' Poudre School District Warehouse December 2008 ' 4.0 [1 CONCLUSIONS 4.1 Compliance with Standards All computations that have been completed within this report are in compliance with the City of Fort Collins "Storm Drainage Design Criteria and Construction Standards" and the "Urban Drainage Storm Drainage Criteria Manual". 4.2 Drainage Concept ' The proposed drainage concepts presented in this report and on the Overall Utility and Drainage Plan adequately provide for an overall conveyance, detention and stormwater ' quality treatment of proposed impervious areas. Final drainage reports for this development will provide further design and information to ensure that this overall development plan will ' be followed and that flows will be conveyed safely. Final drainage reports will address erosion control and best management practices. ' 5.0 REFERENCES 1 1. "Storm Drainage Design Criteria and Construction Standards", City of Fort Collins, Colorado, May 1984. 2. Urban Storm Drainage Criteria Manual, Volume 1, Urban Drainage and Flood Control District, Denver, Colorado, June, 2001. City of Fort Collins ODP Drainage Report for Page 4 Poudre School District Warehouse December 2008 I 1 1 developed area and increased flows will be detained in proposed detention Pond B. These flows will also be released into the Ditch. Pond B will include water quality capture volume. Sub -basin C: This sub -basin consists of 3.6 acres, is located in the southwest corner of the site and is triangular in shape. No use is firm on this parcel. The Ditch is located to the northeast and Prospect Road is located to the south of this basin. CW Subtrust property is located to the west. This basin was analyzed assuming 70% impervious developed area and increased flows will be detained in proposed detention Pond C. These flows will be released into the Ditch. Pond C will also include water quality capture volume. Please refer to the Appendix for the hydrologic calculations for these basins. 3.0 DRAINAGE FACILITY DESIGN 3.1 General Concept The majority of the proposed development will be routed via sheet and gutter flow to the proposed water quality and detention ponds. The ponds will release the detained 100-yr flows into the Ditch. ' 3.2 Detention and Water Quality The detention ponds have been preliminarily sized using the U.S. Federal Aviation ' Administration Equation (FAA Method). The ponds are required to store the 100-yr developed flows and presently assumed to release at the 2-yr existing rate. The Urban Drainage Storm Drainage Criteria Manual was used to determine the water ' quality capture volume. A 40-hour brim -full volume drain time for extended detention basin was used. ' The ponds will be refined during final designs. Please refer to the Appendix for the FAA Method and WQCV calculations. City of Fort Collins CDP Drainage Report for Page 3 Poudre School District warehouse December 2008 ' 2.0 1 1 1 1 DRAINAGE BASINS AND SUB -BASINS 2.1 Major Basin Description The site does not lie within a City of Fort Collins master drainage basin. The majority of the site drains via overland flow to the Ditch were it is then conveyed east and discharges to the Timnath Reservoir. The site is within Timnath's Master Drainage Plan. No specific improvements are indentified for this site. 2.2 Developed Basin Description The proposed development will increase the amount of runoff that currently exists on the site because of an increase in impervious area due to development. Each developed basin is currently planned to detain the 100-yr developed conditions to the 2-yr existing release rate. For the purposes of this report, the 2-yr existing release rate was assumed to be 0.2 cfs/acre. Based on conversations with the Ditch Company, it is acceptable to release detained flows directly into the Ditch. Off -site detained flows from Kitchell Subdivision will pass through the site as they do today. For the purposes of the ODP, the site has been broken into three developed sub -basins: A, B and C. All developed sub -basins are delineated on the ODP Overall Utility and Drainage Plan included in the Appendix of this report. As the site develops, patterns and pond locations may be changed. The ODP plan will be used as a guide for future development. Sub -basin A: This sub -basin is located west of County Road 5 and is bounded by the Ditch to the south and Kitchell Estates to the north. This site is presently assumed to be a school site. It consists of 34 acres and was analyzed assuming 40% impervious developed area. Increased flows will be detained in proposed detention Pond A and will be released into the Ditch. Pond A will also include water quality capture volume. Sub -basin B: This sub -basin consists of 51 acres and contains the majority of the site. This portion of the site is assumed to be a transportation facilities use. It is bounded to the north by Kitchell Estates, to the east by sub -basin A and to the west by CW Subtrust property (a future industrial development). The Ditch is located to the south of this sub -basin. The basin was analyzed assuming 70% impervious City of Fort Collins CDP Drainage Report for Page 2 Poudre School District Warehouse December 2008 ' 1.0 GENERAL LOCATION AND DESCRIPTION ' 1.1 Location The proposed site is a tract of land located in Section 15, Township 7 North, Range 68 West of the Sixth Principal Meridian, City of Fort Collins, Larimer County, Colorado. In particular, it is located on the north side of East Prospect Road between I-25 and County ' Road 5. The proposed site is approximately 98.5 acres. Please refer to the Appendix for the vicinity map. ' 1.2 Description of the Property ' The proposed site is a rectangular shaped parcel that is currently covered by an irrigated farm field and slopes south at an average slope of 0.5%. An existing irrigation ditch, Cache La ' Poudre Reservoir Inlet (Ditch), runs along the south of the site. The proposed improvements to this site will generally consist of uses allowed in the UE, Urban Estate and I, Industrial ' Zoning Districts including but not limited to public facilities and schools. The property is currently owned by the Poudre School District and their intent is to share a warehouse and facility management project with Larimer County. There could be a future school on the ' easterly 34 acres of the property. Please refer to the Appendix for the Overall Utility and Drainage Plan. ' The site is not located within a Federal Emergency Management Agency (FEMA) designated ' floodplain. City of Fort Collins ODP Drainage Report for Page 1 ' Poudre School District Warehouse December 2008 [1 1 TABLE OF CONTENTS 1 1.0 GENERAL LOCATION AND DESCRIPTION................................................................ 1 1 1.1 Location ....................... ...................................................................................................1 1.2 Description of the Property ............................................................................................. 1 1 2.0 DRAINAGE BASINS AND SUB-BASINS....................................................................... 2 2.1 Major Basin Description................................................................................................. 2 2.2 Developed Basin Description.......................................................................................... 2 1 3.0 DRAINAGE FACILITY DESIGN..................................................................................... 3 3.1 General Concept.............................................................................................................. 3 ' 3.2 Detention and Water Quality .......................................................................................... 3 4.0 CONCLUSIONS...........:...............................................................................:.....................4 1 4.1 Compliance with Standards............................................................................................ 4 4.2 Drainage Concept............................................................................................................ 4 5.0 REFERENCES.................................................................................................................... 4 1 1 APPENDIX VICINITY MAP 1 OVERALL UTILITY AND DRAINAGE PLAN HYDROLOGIC CALCULATIONS 1 WQCV AND DETENTION VOLUME CALCULATIONS 1 1 1 1 1 1 INTE RWEST C O N S U L T I N G G R.O U P December 23, 2008 Glen Schlueter . City of Fort Collins Stormwater 700 Wood Street Fort Collins, CO 80522-0580 RE: Overall Development Plan Drainage Report for Poudre School District Warehouse Dear Glen, I am pleased to submit for your review and approval, this Overall Development Plan (ODP) Drainage Report for the Poudre School District Warehouse. This report is a general analysis of the Poudre School District Warehouse site and gives a general drainage design for the entire area. It is to be used as a guide for development of this area. This report for the drainage design was prepared in accordance with the criteria in the. City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, p oho :R�Q�r Michael Oberlander, P.E., L.S.I. A 1218 WEST ASH, SUITE C WINDSOR, COLORADO 80550 TEL. 970.674.3300 • FAX. 970.674.3303 CITY OF FORT COLLINS OVERALL DEVELOPMENT PLAN DRAINAGE REPORT FOR POUDRE SCHOOL DISTRICT WAREHOUSE PREPARED BY: INTERWEST C❑NSULTING GROUP 1 21 B WEST ASH, SUITE C WINDSOR, COLORADO 80550 PHONE: 970.674.330❑ FAX: 970.674.3303 DECEMBER 23, 2008 INTERWEST = CONSULTING GROUP