Loading...
HomeMy WebLinkAboutCENTRE AVENUE RESIDENCES - MOD - 37-08 - CORRESPONDENCE -Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number: 1 Created: 12/2/2008 [12/2/08] No comments on the modification Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Steve Olt City Planner Page 3 Number: 6 Created: 12/3/2008 [12/3/08] FIRE LINE REQUIREMENT: Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. Number: 7 Created: 12/3/2008 [12/3/08] KNOX BOX REQUIRED: Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new building equipped with a required fire sprinkler system or fire alarm system. 97UFC 902.4; PFA BUREAU POLICY 88-20 Number: 8 Created: 12/3/2008 [12/3/08] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: • Commercial, 1,500 gpm at 20 psi residual pressure, spaced not farther than 300 feet to the building, on 600-foot centers thereafter • Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not farther than 400 feet to the building, on 800-foot centers thereafter • Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not farther than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2 Number: 9 Created: 12/3/2008 [12/3/08] ADDRESS NUMERALS: Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 97UFC901.4.4 Number: 10 Created: 12/3/2008 [12/3/08] REQUIRED ACCESS: Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route (from a public street) around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: ❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ❑ Have appropriate maintenance agreements that are legally binding and enforceable. ❑ Be designated on the plat as an Emergency Access Easement. ❑ Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet for buildings three or more stories in height). ❑ A fire lane plan shall be submitted for approval prior to installation. If a fire lane is not provided, all buildings out of access (exceeding the 150400t requirement) shall be equipped with an approved automatic fire -sprinkler system. 97UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1 Page 2 A d f.f� • • STAFF PROJECT REVIEW ON of Fort Collins VFR DESIGNS JENNIFER ALMSTEAD 401 W MOUNTAIN AVE FORT COLLINS CO 80521 Date: 12/3/2008 Staff has reviewed your submittal for CENTRE AVENUE RESIDENCES -MODIFICATION OF STANDARDS TYPE 11, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 11 Created: 12/3/2008 [12/3/08] This modification request, with the buildings to exceed 40 feet in height, is subject to the Special Building Height Review as set forth in Section 3.5.1(G) of the Land Use Code. This review must take place before the request can be schdeuled for a Planning & Zoning Board hearing. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 2 Created: 12/3/2008 [12/3/08] STANDPIPES AND FIRE PUMP: From a Fire Code perspective, this appears to be a four-story building (one level of parking, under three stories of residential. Buildings four or more stories in height are required to be equipped with firefighting standpipes in every stairwell. The standpipe system must be capable of supplying a minimum 100 psi to the top floor; an approved fire pump may be required to obtain this minimum pressure. IFC 905.3.1 Number: 3 Created: 12/3/2008 [12/3/08] STAIRWELL SIGNAGE: Approved stairwell identification signs shall be posted at each floor level in all enclosed stairways in buildings four or more stories in height. 97UFC1210.4 and Appendix I-C Number: 4 Created: 12/3/2008 [12/3/08] SPRINKLER REQUIREMENTS: The proposed buildings shall be equipped with approved, automatic fire -sprinkler systems Number: 5 Created: 12/3/2008 [12/3/08] FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. If possible, a fire hydrant shall be located within 100 feet of the FDC. PFA Bureau Policy Page 1