[4/10/09] Can be done at Final Compliance.
[2/27/091 Please add text in the drainage report to compliment the calculations stating how the flows are
less than the previously approved drainage report.
Number:41 Created:2/27/2009 Pending
[4/101091 Can be done at Final Compliance.
[2/27/091 If the private drive south to Timberline Church is to be built with this replat, sizing and design of
the culvert would need to be included.
Number:42 Created:4/6/2009 Pending
[4/6/09] PDP can go to a hearing. More comments may follow during Final Compliance.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: WaterMastewater
Number:49 Created:4/7/2009 Pending
[4/7/09] Revise Construction Note 2 on sheet PDP-4 as shown on the redlined plans.
Number:50 Created:4/712009 Pending
[417/091 Mark the sewer service to Lot 3 "private".
.:
Staff Review Comments
FCollins
fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan
shall be submitted for approval prior to installation. In addition to the design criteria already contained in
relevant standards and policies, any new fire lane must meet the following general requirements:
• Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting
fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at
construction sites.
• Have appropriate maintenance agreements that are legally binding and enforceable.
• Be designated on the plat as an Emergency Access Easement.
• Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at
least one long side of the building when the structures are three or more stories in height).
If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official
is authorized to increase the dimension of 150 feet. PLEASE NOTE: The area shown as Public Access
must also be designated on the plat as an EAE. Thank you for showing the3 FIRE LANE - NO PARKING
signs.
2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
Number:25 Created:2/25/2009 Unresolved
TURNING RADII: The required turning radii of a fire apparatus access road shall be a minimum of 25 feet
inside and 50 feet outside 2006 International Fire Code 503.2.4 and Appendix D103.3
Number:26 Created:2/25/2009 Pending
[4/8/09] PFA will have additional comments when Lots 2 and 3 are developed.
FUTURE PROJECTS: Please note that additional fire comments likely will be provided based on future,
proposed structures.
Department: Transportation Planning
Topic: General
Issue Contact: Jennifer Petrik
Number:27 Created:2/25/2009 Unresolved
[2/25/09] An access easement will be required for the private sidewalk. An easement will also be required
for the section of sidewalk located on the Church property.
Number:28 Created:2/25/2009 Unresolved
[4/14/091 Repeated comment (clarification). Please make the sidewalk connection to the pedestrian ramps
more organic to fit a more natural traveled path for wheel chairs, pedestrians etc.. The current angle is
sharp and would be difficult to maneuver.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: Plat
Number:48 Created:4/7/2009 Pending
[4/7/09] Add a note on Lots 2 and 3 that water services to these lots to be installed by builder/developer
when these lots are developed.
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Stormwater
Number:40 Created:2/27/2009 Pending
N.
Staff Review Comments ���'*�af
LL
Ins
Number:33 Created:2/27/2009 Pending
[4/7/09] Your response letter states that this was removed but in fact, it is still there. If this is meant to be a
horizontal control plan, then label it as such. If it is the site plan, please take it out but transfer all relevant
information to the grading and utility plan sheets.
[2/27/091 Please remove the site plan from the utility set or did you mean this to be more of a horizontal
control plan?
Number:34 Created:2/27/2009 Pending
[4l7/09] Repeat comment.
[2/27/091 Please show removals and approximate street cuts. Please note that if the existing curb and
gutter can not be removed in such a way that the street asphalt is not damaged, then all street patching
must be done in accordance with city standards. Just an fyi..that means that the street patch occurs at the
lane line or in the middle of the travel lane when a cut is made parallel to the curb and gutter.
Number:47 Created:41712009 Pending
[4/7/09] What is the private drive constructed out of? Please provide a typical cross section as well.
Department: Forestry Issue Contact: Tim Buchanan
Topic: General
Number:29 Created:2/27/2009 Unresolved
[2/27/09] Street tree will be required along Timberline with future PDPs.
Department: PFA Issue Contact: Carle Dann
Topic: Fire
Number:23 Created:2/25/2009 Pending
[4/8/09] Per our discussion at Staff Review, if a hydrant is not added to the site (internal hydrant), the
building will be required to have an approved automatic fire -sprinkler system.
WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having
jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements
based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at
20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter;
residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400
feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20
psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter.
These requirements may be modified if buildings are equipped with automatic fire sprinkler systems.
PLEASE NOTE: Applicant will need to install an additional fire hydrant internal to the project (adjacent to
private drive). Please contact me about an approved location for this hydrant. Also, because of the size of
the water main, hydrants in the area should meet minimum flow requirements and does not need a flow
test.
2006 International Fire Code 508.1 and Appendix B.
Number:24 Created:2/25/2009 Unresolved
REQUIRED ACCESS: Fire access roads (fire lanes) shall be provided for every facility, building or portion
of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the
facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from
fire apparatus access as measured by. an approved route around the exterior of the building or facility. This
N
Pending
[4/7/09] The site and utility plan sets need to show all existing features within 150' of the project limits and
identify all offsite easements. Please refer to LCUASS chapter 2 and 3 for basic information that must be
shown on all plan sets in addition to specific chapters dealing with onsite design. Appendix E4, the
checklist, is a good start but it is not all inclusive.
Number:46 Created:4/7/2009 Pending
[4/7/09] Please provide directional ramps at the driveway entrances.
Topic: Plat
Number:38 Created:2/27/2009 Pending
[4/7/09] Still not quite right.
[2/27/09] Please correct the first paragraph of the Statement of Ownership. I can email that document to
you if you email the request to me at sjoy@fcgov.com
Topic: Site Plan
Number: 45
Created:4/7/2009 Pending
[4/7/09] This is not a site plan ... it is more like a utility plan. Please see your project planner for site plan
requirements.
Topic: Utility Plans
Number:4 Created:2/24/2009 Pending
[417109] You missed quite a few items that are required on the plan sets before going to public hearing and
labeled them instead as NA. This is not correct. Please go through Appendix E4 and address all
highlighted items that are not shown or shown incorrectly on your plan set. Please call if you have
questions so we can avoid unnecessary rounds of review.
[2/24/09] Please see LCUASS for all utility plan requirements and go through and complete all highlighted
items in Checklist E4 with the next round of review. All highlighted items must be designed in the plan sets
before the project may go to hearing. All other applicable items must be completed in Final Compliance
and prior to final plan approval.
Number: 18
Staff Review Comments
art Collins
4. The bearings on site, grading and utility plans do not match the plat. The basis of bearings on cover
sheet (PDP) does not match the plat either.
5. We would prefer to NOT use "Block" on this plat, just lots 1, 2 and 3.
Number: 44 Created: 4/7/2009
Created:2/25/2009 Pending
[4/7/09] Again, your line weights are off. Please use dark lines for proposed and grey lines for existing.
The way the utilities are currently shown, it appears that several street cuts are required but only one is
shown.
[2/25/09] Please show the approximate location of the street cut on the utility sheet in accordance with
Chapter 25 of LCUASS and add the street cut note:
Limits of street cut are approximate. Final Limits to be determined in the field by the City Engineering
Inspector. All repairs to be in accordance with City street repair standards.
v
Staff Review Comments
Date: 4/14/2009
art Collins
RIGDEN FARM,15TH FILING PDP - TYPE I (formerly 1st filing tract A Replat)
SELECTION CRITERIA: Status = Unresolved
ISSUES:
Department: Current Planning Issue Contact: Emma McArdle
Topic: Site Plan
Number: 51 Created:4/14/2009 Pending
[4/14/091 Please see the example Site Plan included with Redlines. There is also a copy of the site plan
requirements with the applicable requirements highlighted for you. The site plan should be a stand alone
document. It should not be included in the Utility Plans.
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number:5 Created:2/24/2009 Pending
[4/7/09] Repeat comment. A formal variance request is required if proposing anything other than a 15'
curb return radius. Please see LCUASS 1.9.4 for variance request requirements.
[2/24/09] All driveways must be constructed in accordance with LCUASS detail 707. Curb return radii must_
meet LCUASS table 8-2 requirements.
Number:14 Created:2125/2009 Pending
[4/7/09] 1 will need at minimum a letter of intent from the church property before allowing this project to go
to hearing. The actual easement itself will be required in Final Compliance and prior to final plan approvals.
[2/25/09] Is there an access easement on the Timberline Church property allowing access to their private
driveway? If not, one will be needed before this development can be approved. A letter of intent to grant
this easement signed by the Church property owner will be required prior to hearing and the actual
easement itself will be required prior to final plan approval.
[4/14/09] The letter of intent has been forwarded on to Engineering. (Emma McArdle)
Number:16 Created:2/25/2009 Pending
[4/7/09] Again, what triggers the vacation of this easement?
[2/25/091 There is a 25' wide temporary slope easement dedicated off the back of Timberline... what
triggers the vacation or termination of the easement?
Number:17 Created:2/25/2009 Unresolved
[2/25/091 The easements do not match from plat to utility plan.
Number: 43
[4/7/09] From Technical Services:
Created:4l7/2009 Pending
1. Plat boundary and legal close.
2. Plat: Easement dimension along east line of Lot 3 does not match the linework when scaled.
3. Scanning issues on grading, utility and drainage plans.
•l
it
' of
FortColtins
April 14, 2009
Scott Maier
Armstrong Development Properties, Inc.
1610 Wynkoop Street, Suite.120
Denver, CO 80202
Dear Scott,
Current Planning
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov. com/currentplanning
The attached are comments from City Staff concerning the request for Rigden Farm, Fifteenth
Filing, which was presented before Staff Review on April 8, 2009.
This is a request to replat Tract A of Rigden Farm Filing One into three (3) separate lots and
dedicate an access easement on the 2.7 acre site. The site is bounded by South Timberline Road
to the west, Custer Drive to the north, Illinois Drive to the east and the Timberline Church to the
south. This is the first of four potential PDPs. The entire site is in the NC, Neighborhood
Commercial zoning district.
Following Staff Review, it was determined that staff shall require a third round of review for this
proposal. Please make revisions per staffs comments prior to next submittal. If you have
questions regarding any comments please get in touch with the contact that raised the particular
issue.