HomeMy WebLinkAboutBY DESIGN (500 S. WASHINGTON AVE.) - PDP - 6-07 - CORRESPONDENCE - (6)V Number:43 Created:3/15/2007 [3/15/07] (FC) Missing two lot corner spot elevations. p K Department: Stormwater-Water-Wastewaterlssue Contact: Wes Lamarque Topic: Floodplain Number: 36 Created: 2/27/2007 [3/20/07] Repeat Comment. [2/27/07] 1. Please include the 100-year floodplain boundaries on the plat. f3k f 2. A floodplain use permit is required for construction of the driveway since it is in the floodplain. ✓Topic: Stormwater Number: 49 Created: 3/20/2007 [3/20/07] Stormwater is ready for a hearing. No more comments before Hearing. Vi Department: Stormwater-Water-Wastewaterlssue Contact: Roger Buffington Topic: Water/Wastewater Number: 45 Created: 3/19/2007 [3/19/07] As shown on the plans, it's doubtful that the sewer service could be installed or maintained without encroaching where there is no easement. It appears that two 45-degree bends are needed. Kt�-OC-Amp s5rVcle� Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, &Wbq Shelby Sommer Associate City Planner Page 3 Topic: Plat Number: 26 Created: 2/23/2007 [3/15/07] (FC) [2/23/07] Please see 3.2.7E for Vicinity Map scaling. ✓Number: 51 Created: 3/22/2007 [3/22/07] From Technical Services: Boundary closes. / Number:52 Created: 3/22/2007 [3/22/07] From Technical Services: Typo in legal. Should be Northwest 1/4, not Northeast. CW /Number: 53 Created: 3/22/2007 [3/22/07] From Technical Services: Would like to see title changed to: Westlawn Addition ... Replat of Lots 1 and 2, Block 1. t+` K From Engineering: Please change title to match plat on all plan sets (site, landscape, utility). d5j< /Topic: Site/Landscpae Plan if Number: 39 Created: 3/1512007 [3/15/07] (FC) Since your company likes to use a different project name in the title block, please place the project title to match the utility and plat plans across the top of the site and landscape plan so that we at the city can file them correctly. Thanks. Topic: Utility Plans Vumber: 17 Created: 2/22/2007 /15/07] (FC) In addition to those shown, please provide details 701, 1601 and 1602. a> K [2/22/07] Please provide all appropriate details (Final Compliance). Topic: Utility Plans - General Number: 38 Created: 3/15/2007 [3/15/07] Great submittal! This project is ready for hearing pending the receipt of the letters of intent. I have a few comments but they are all for final compliance. I will include them with this review just so we can get through Final Compliance with one review and then straight to mylars. Thanks for the great job you did! V Number:44 Created: 3/15/20 07 [3/15/07] (FC) See redlines for other comments. D}C qa1� ✓Topic: Utility Plans - Grading Number: 42 Created: 3/15/2007 [3/15/07] (FC) Add the note: The top of foundation elevations shown are the minimum elevations required for protection from the 100-year storm. pk Page 2 L: City of Fort Collins STAFF PROJECT REVIEW BY DESIGN HOMES PO BOX 270457 FORT COLLINS, CO 80522 Date: 03/23/2007 Staff has reviewed your submittal for BY DESIGN (500 S WASHINGTON AVE) PDP- TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Shelby Sommer Topic: Landscape Plan /Number: 48 Created: 3/20/2007 1/ [3/20/07] (Final Compliance) Since the site and landscape plans have been separated onto 2 sheets, you only need to include the signature blocks (owner and Director of Planning) on the Site Plan. oK /Number: 50 Created: 3/21 /2007 [3/21/07] (Final Compliance) Please add tree protection and general landscape notes to landscape plan (see attached document for information). Also, use different symbols for existing vs. proposed landscaping. Please clearly show which tree is proposed to be removed. 6 K Topic: Modification Request Number: 4.6 Created: 3/20/2007 [3/20/07] (Before Hearing) Thank you for providing the modification of standards request. In your request, please provide a direct citation of the code language v/(Division 4.7(D)(1)) in addition to the information that you provided. Also, please provide record,of your modification request on the site plan next to the density calculation. c >)C `Topic: Site Plan Number: 47 Created: 3/20/2007 [3/20/07] Please be aware*that if the south wall of the new house exceeds 18 feet in height, the side yard setback along the south side will need to be increased. U-K - 00-Ga Why MoY�D Department: Engineering Issue Contact: Susan Joy Topic: General umber: 40 Created: 3/15/2007 [3/15/07] (FC) Minimum residential driveway widths are 12' to the row. You can narrow it down after that if you like, no problems there. K EYI5GP -r'o I Z' Aumber: 41 Created: 3/15/2007 [3/15/07] (FC) All plan sets - the proposed offsite easements need to be labeled as "15' Utility Easement dedicated by separate document, reception # XXXXX". P�*Asr'-Mlok+s j;��MovI,ID Page 1 f