Loading...
HomeMy WebLinkAboutHIDDEN POND ESTATES - FDP - 11-07/A - CORRESPONDENCE -11. Please specify the type of well screen that will be used in conjunction with the water quality plate. 12. Please indicate on plans where the headwall detail will be used. 13.The silt fence is shown to be wrapped around the swale between lots 7 and 8. A temporary straw bale check dam might work better in that situation. 14. Please see redlined plans for additional comments. Topic: Water/wastewater Number: 56 Created: 9/19/2007 [9/19/07] Please add a legend to all utility plans. Will need one more round of paper review before proceeding to mylars stage. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterAvastewater Number: 57 Created: 9/19/2007 [9/19/07] Revise the plans to show the fire hydrant assemblies in the cul-de-sacs using swivel tees with a plug and thrust block at the end of the tee. (See sketch on redlined plans.) Number: 58 Created: 9/19/2007 [9/19/07] It is noted that the FCLWD water service which previously served the existing house is being converted to an irrigation tap for the development. As a result, water development fees will be due for the new water service supplying water to Lot 1. These fees include the Water Plant Investment Fee (WPIF) and Raw Water Requirement (RWR) which are based upon the number of living units (in this case - one) and the lot area. For large lots, these fees are calculated on a maximum of a half acre. If the RWR is satisfied with cash, the total water development fees for Lot 1 will be nearly $18,700 based upon 2007 fees. The 2008 fees will likely be higher for the WPIF's. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, '4&q lg� Shelby Sommer Associate City Planner Page 5 Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 53 Created: 9/18/2007 [9/18/07] An additional fire hydrant needs to be installed to better provide a water supply for the structures to be built on Hidden Pond Drive. The best location would be the east end of Lot 1 or west end of Lot 2, adjacent to Hidden Pond Drive. Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan Topic: Stormwater Number: 55 Created: 9/19/2007 1. [9/19/07] Please specify how the roadside swales will be vegetated. Add a note indicating who will be responsible for maintaining these. 2. Trees within roadside swales should be planted on top of bank, add a note to landscape plan to that specifying that trees shall not be placed in a manner that would impede drainage flows. 3. Grading plan does not specify lot grading. How will these be certified? A plot plan showing individual lot grading will be required prior to building permit. 4. Approval by the FCRID irrigation company (North Poudre Irrigation) will be required prior to final plan approval by the City of Fort Collins. 5. Please specify a minimum cover for all storm lines on storm line profile sheet. 6. Plat should include roadside swale in a drainage easement along with tract for paved area. Plat notes should indicate who maintains roadside swale and what type of landscaping can be done. No landscape rocks or other materials that can be washed out will be allowed. 7. Please add a legend to the grading plan. Show limits of disturbance. 8. Please add a note stating that the area downstream of the pipe between lots 7 and 8 might need permanent erosion protection. In the event of erosion problems or head cutting, within the first five years of construction, the developer shall install structural stabilizing measures to be reviewed and approved by the City of Fort Collins. 9. Pond C seems to have no freeboard. Please show spillway design in cross- section, and request a variance in the drainage report if the one foot freeboard cannot be achieved as currently stated in report. 10. Specify which water quality outlet detail will be used. The modified water quality outlet detail that is shown on the plans is to be used, please add a TxT maintenance pad in front of box, and make sure it is keyed into the soil. Page 4 [9/20/07] The private drives need to be placed in a Tract - not defined as easements across the lots. This is necessary to meet the definition of a private drive and for the private drive to be named. Number: 60 Created: 9/20/2007 [9/20/07] Comments from Technical Services: 1) Boundary and legal close. 2) Can not name easements (see comment #59) 3) Plat needs "Natural Area Buffer" Note. Need to define on the plat what a natural area buffer is (i.e. what is allowed and not allowed in this area). Number: 61 Created: 9/20/2007 [9/20/07] Need to add the private drive maintenance note to the plat. Number: 62 Created: 9/20/2007 [9/20/07] There is a conflict in the Tract numbering/lettering. The plan view shows lettering, but the table numbers them. Department: Engineering Issue Contact: Susan Joy Topic: Plat Number: 45 Created: 9/11 /2007 [9/11/07] The row was vacated by council so it needs to be labeled as "row vacated by ordinance #xx" or something to that effect. This needs to be carried throughout all of the various plan sets as well. Topic: Site Plan Number: 48 Created: 9/11 /2007 [9/11/07] Remove the words "Final Plan" out of the project title and title block title. Number: 49 Created: 9/11 /2007 [9/11/07] See Appendix E6 for all scanning requirements and bring the plan set up to standard. Remove the shading, correct all line over text labeling, etc. Topic: Utility Plans Number: 44 Created: 9/11 /2007 [9/11/07] Beautiful job! The only comment I might offer is the shading of the private drive ... I talked to JR and he said you can leave it on the horizontal control sheets but to please take it off the utility, grading and drainage sheets. Department: Light & Power Topic: Utility Plans Number: 54 [9/18/07] No comments Issue Contact: Janet McTague Created: 9/18/2007 Page 3 Department: Current Planning Issue Contact: Shelby Sommer Topic: Plat Number: 8 Created: 5/23/2007 [9/12/07] The Tract Table lists the Tracts as 1, 2, 3 but the plat shows Tracts A, B, C. Please correct. [5/23/07] Please add a tract table to the subdivision plat. This table should include ownership and maintenance information for each tract in the subdivision. Also, remember that as required in cluster developments, at least 50 percent of the site area must be preserved as permanent, private open space. It looks like Tract C will satisfy this requirement, but please indicate so in the tract table. Topic: Site Plan Number: 11 Created: 5/23/2007 [9/12/07] The fence symbol is still difficult to see underneath the darker boundary symbol. Please add a label and try to adjust the overlapping. [5/23/07] Is any new fencing proposed? The symbol for the existing fence along the western edge of the property did not print clearly. Will this remain or will you be removing it? Number: 51 Created: 9/12/2007 [9/12/07] See highlighted areas on the site plan that may have scanning issues. Please try to make these areas as clear as possible and avoid overlapping symbols and text. The landscaping outlines on the site plan are very light and will not scan or reproduce. Please remove or darken these symbols. Department: Engineering Issue Contact: Susan Joy Topic: General Number: 50 Created: 9/11 /2007 [9/11/07] No redlines to return with this round and I do not need another round of review prior to going to mylars. Just please be sure to address the few comments I had before printing them however. If you have any questions about the scannability of the plan sets, please see JR in Tech Services as I will be on vacation from 9/14 to 9/23. Topic: Landscape Plan Number: 46 Created: 9/11 /2007 [9/11/07] Removing the contours should help with the scannability of the plan sets. See Appendix E6 for other scanning requirements. Number: 47 Created: 9/11 /2007 [9/11/07] Remove the words "Final Plan" out of the project title and title block title. Department: Engineering Issue Contact: Sheri Langenberger Topic: Plat Number: 59 Created: 9/20/2007 Page 2 STAFF PROJECT REVIEW JASON AND WEND[ BELD 6215 WESTCHASE RD FORT COLLINS, CO 80528 Date: 09/24/2007 Staff has reviewed your submittal for HIDDEN POND ESTATES PDP - TYPE II, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Shelby Sommer Topic: General Number: 41 Created: 8/28/2007 [8/28/07] The following departments have no further concerns: Water Conservation, Poudre School District, Number: 42 Created: 9/11 /2007 [9/11/07] Don Kapperman (Comcast): The overall site plan shows side lot and rear lot easements, and the plat map does not show a 6' easement for Comcast/Quest. Number: 43 Created: 9/11 /2007 [9/11/07] Lisa Thieme (Assessment Technician, Larimer County Assessor's Office): The review copy shows the owners of the property as Beld Developments. The name of the owner should read "Beld Developments, LLC." Please contact me at 498-7097 if you have questions. Topic: Landscape Plan Number: 52 Created: 9/12/2007 [9/12/07] The existing landscaping bubbled areas on the Landscape Plan are difficult to see and will not scan properly. Please use a different line weight or symbol. Department: Current Planning Issue Contact: Dana Leavitt Topic: Landscape Plan Number: 37 Created: 6/4/2007 [9/12/07] An important part of the discussion has not been addressed. The existing pasture areas need to be broken up prior to reseeding to allow the native grasses to succeed. Removing incompatible landscape materials is cited in Section 3.4.1(E)(1)(g) of the Land Use Code. It was verbally agreed that a total eradication program was not needed, but to use a less intrusive method of breaking up the grass to allow for new species of grasses to grow. [6/4/07] The open space shall be revegetated with native grass and shrub species. A mix of native plant and pasture gasses is not compatible. Page 1