HomeMy WebLinkAbout318 WEST MYRTLE TOWNHOMES - PDP - 5-09 - SUBMITTAL DOCUMENTS - ROUND 8 - (2)i
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at 221-6341.
Yours
j �Tpruul(y`, ou
Stec/U OlZt W
City Planner
cc: Marc Virata
Current Planning file #5-09
Page 5
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Stormwater '
Number: 11 Created: 2/19/2009
[2/19/09] A more detailed grading plan needs to be submitted for review to determine if the
site will drain properly and without negatively affecting neighboring properties. The datum
used needs to be clarified on the plans. If the datum is not an official City of Fort Collins
datum, than please provide a note stating such.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: Water/Wastewater
Number: 6 Created: 2/17/2009
[2/17/09] Is the sewer service shown extending to 318 the existing service? If yes, will it be
re -used for the 5-plex?
Number: 7 Created: 2/17/2009
[2/17/09] Provide information on fire sprinkler system so that determination can be made
regarding fire line/domestic water service requirements. Add notes regarding the
abandonment on the existing 3/4-inch water service. The service must be abandoned at the
main. If coordinated with the new 1-inch service, this work can be done at the same time that
the new 1-inch service tap is installed.
Department: Zoning Issue Contact: Peter Barnes
Topic: Zoning
Number: 2 Created: 2/6/2009
[2/6/09] The drive aisle width in the parking lot needs to be 24' per Section 3.2.2(L).
Number: 3 Created: 2/6/2009
[2/6/09] Need one deciduous tree per every 40' lineal feet of the parking lot perimeter
landscape strip. Also need a 6' tall privacy fence along the north and west lot lines abutting
the parking lot (Sec. 3.2.1(E)(4)).
Number: 4 Created: 2/6/2009
[2/6/09] Please show all the cantilevers on the Site Plan.
Number: 5 Created: 2/6/2009
[2/6/09] Please show the building footprint dimensions on the Site Plan.
A "formal" re -submittal of the PDP documentation is not needed prior to the required
administrative public hearing. However, there are several issues that must be addressed with
the appropriate City department before the hearing can be scheduled. Be sure and return all
red -lined plans when you submit the required Final Plan documentation for staff review after
the public hearing is held.
Page 4
Please add two vertical control benchmarks in accordance with City benchmark datum
to help in verifying the elevations on the plan set.
Please add a note on the plan set indicating that all existing substandard curb, gutter and
sidewalk as well as curb, gutter and sidewalk damaged during the course of construction
are required to be replaced in accordance with City standards.
Number: 14 Created: 2/20/2009
[2/20/09] The developer requested a contact person for Qwest. Bill Johnson at 970 377-
6401 (bpjohn2@gwest.com) has been the contact we've regularly used.
Number: 15 Created: 2/20/2009
[2/20/09] I just noticed on the landscape plan that the trash enclosure detail shows swinging
doors which would swing out into the right-of-way and would not be permitted. Please use
either a sliding door system or (if possible) reorient the trash enclosure in a manner that
prevents swinging doors from entering the right-of-way.
Number: 16 Created: 2/20/2009
[2/20/09] Upon verification on revised drawings for ID #8 and #15, the project would be
ready fro a hearing from Engineering's perspective. The remaining comments can be
addressed at the time of final plan review.
Department: Light & Power Issue Contact: Doug Martine
Topic: Electric Utility
Number: 1 Created: 2/2/2009
[2/2/09] It is assumed that the house at 320 W. Myrtle will remain a single family residence.
It is also assumed that the 318 West Myrtle Townhomes will each have an electric service
not to exceed 125 amps, and will NOT use electric space heating. The developer will then
need to provide an off -site easement across the rear of the property at 516 Meldrum. If these
assumptions are not correct, a new electric transformer will be required near the corner of the
alley and Myrtle. Normal electric development and system modification charges will apply,
as well as costs to obtain the off -site easement. Please coordinate power requirements with
Light & Power Engineering at 221-6700.
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 12 Created: 2/19/2009
Thank you for responding to the Conceptual Review comments. PFA has no additional
comments or concerns at this time.
Page 3
Number: 22
Created: 2/24/2009
[2/24/09] City staff had indicated at staff review on Wednesday, February 18th that the
project did not have to go through another round of review before scheduling the
administrative public hearing; however, several departments (Engineering,
Water/Wastewater, Stormwater, Historic Preservation, and Zoning) had comments that need
to be addressed before scheduling the hearing. Peter Barnes' Zoning comments are the most
significant and must be addressed to his satisfaction prior to scheduling the hearing.
Department: Engineering
Topic: Engineering
Number: 8
Issue Contact: Marc Virata
Created: 2/17/2009
[2/17/09] Is the overhead utility line along the east side of the property proposing to remain
or be removed? The drawings don't appear to show the existing overhead, which seems to
imply it is to be removed. If this is the case, please indicate this on the plan set. If it is
proposed to remain, please show it on the plans and provide conduit for future
undergrounding.
Number: 9
Created: 2/17/2009
[2/17/09] The drawings seem to imply that the alley is of a consistent pavement width along
the frontage, though the pavement width is not consistent along the east side of the property.
Will the alley remain untouched or will some work occur (in conjunction with any potential
undergrounding of the overhead)? The drawings should reflect the condition on the width of
the alley upon completion of the project.
Number: 10
Created: 2/17/2009
[2/17/09] The level of detail on the utility drawing set is less than a typical utility plan set.
will defer to Stormwater and Water/Wastewater as to whether the information provided is
sufficient, with the exception of the following concerns:
- The utility plan set will need to be a separate set from the site plan.
- The utility plan set will need to have City signature blocks added to all sheets.
- Please add a detail for the curb and gutter (Larimer County Urban Area Street Standards
detail #701).
- Should other departments require that the utility plan set be prepared by a professional
engineer, more information will need to be added.
- The owner's certification and director of planning signature blocks should be removed
from the utility plan set. They belong on the Site Plan.
- Ideally the utility plan set should be showing the existing water line on Myrtle to show
the approximate extent of the patching on Myrtle that's needed.
Page 2
aSTAFF PROJECT REVIEW
City of Fort Collins
Bruce M. Froseth & Susan Kreul/Froseth Date: 2/24/2009
524 Spring Canyon Court
Fort Collins, CO 80525
Staff has reviewed your submittal for 318 WEST MYRTLE TOWNHOMES, PROJECT
DEVELOPMENT PLAN (PDP) - TYPE 1, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Electric Utility
Number: 18 Created: 2/24/2009
[2/24/09] Justin Fields of Light & Power (224-6150) indicated that each dwelling unit must
be individually metered.
Department: Current Planning Issue Contact: Dana Leavitt
Topic: Fire
Number: 13 Created: 2/20/2009
[2/20/09] No comments.
Department: Current Planning Issue Contact: Steve Olt
Topic: General
Number: 17 Created: 2/24/2009
[2/24/09] Comcast Cable TV, indicated that they need a 5' wide utility easement outside of
the alley right-of-way. The developer will need to provide a 1" conduit from each home to
the Comcast facility.
Number: 19 Created: 2/24/2009
[2/24/09] Dana Leavitt, the City's Environmental Planner, indicated that the applicant
should minimize materials going to the landfill during demolition.
Number: 20 Created: 2/24/2009
[2/24/09] The request for Modifications of Standards for the front yard and side yard
setbacks do apply because the applicant is adding a second story to the existing structure at
318 West Myrtle Street.
Number: 21 Created: 2/24/2009
[2/24/09] The proposed new front yard setback (1 F-9") for the existing structure at 318 West
Myrtle Street must be shown on the Site Plan.
Page 1