HomeMy WebLinkAbout318 WEST MYRTLE TOWNHOMES - PDP - 5-09 - SUBMITTAL DOCUMENTS - ROUND 8 - CorrespondenceCity/ of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS his development proposal is subject to all applicable standards of the Fort Collins Land Use Code, specifically, but not limited to: • Section 3.2.1 - Landscaping and Tree Protection • Section 3.2.2 - Access, Circulation and Parking • Division 3.5 — Building Standards (including project compatibility) • Division 3.3 - Engineering Standards • Division 4.9 — Neighborhood Conservation Buffer District 9. Please pay particular attention to the parking lot layout and landscaping requirements. All parking stalls, drive aisles and setbacks will need to conform to the standards in Section 3.2.2 of the Land Use code. 10. A walkway will be required to connect the street sidewalk to all dwelling unit entrances. 11. Application forms and PDP submittal requirement checklists can be found online at http:/ffcgov.com/currentplanning/submittals.php. 12. Please contact me if you have questions about speck submittal requirements. 13. Information about Utility Development Fees and Charges can be found online at http://fc_qov.com/utilities/rates-fees.php. 14. Information about Building Permit Fees and the Permitting Process can be found online at http://fcgov.com/nbs/?departments. 15. A neighborhood meeting is not required for Type 1 (Administrative) proposals. I suggest that you discuss your proposal with your immediate neighbors prior to submitting your development plan for review. If you would like to hold a neighborhood meeting please contact me to coordinate the meeting logistics. 16. When you are ready to submit your application to the City for review, please schedule a PDP submittal appointment at the Development Review Center at 221-6760. I City Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS -ma ego the existing house @320 Myrtle er to 1 'h story eave heights on new buildings -massing consistent W/ existing house -siding materials relates to existing material and textures -window proportions repeated/patterns matching existing PLANNING Contact Info: Shelby Sommer, 416-2138, ssommer(c)-fcgov.com 1. For a step-by-step guide to the Development Review process, please visit the Development Review Guide online at: http:/tfcgov.com/dr.g. 2. You will be required to submit a Project Development Plan (PDP) for the City to review. This PDP will be evaluated through the Development Review Process. City of Fort Collins Departments along with other external agencies will have the opportunity to review and comment on your Project Development Plan. 3. A decision (approval, approval with conditions or denial) will be made by the City's Administrative Hearing Officer following an Administrative Public Hearing (Type One Review). If your Project Development Plan is approved at the Public Hearing, you will be required to submit Final Plans for review which will ultimately be recorded. 4. Please be aware that you will owe both the Transportation Development Review Fee (TDRF) and the Development Review Fee with your application submittal. You will follow the Small Project Fee schedule for your Development Review Fee, found on Page 2 of the Development Review Fee Scheduleonline at hftp://fcaov.com/currentplanning/sbbmiftals.php. A final development review fee of $1000 will be charged when final plans are submitted after the public hearing. A final Transportation Development Review Fee of $1000 will also be charged when final plans are submitted after the public hearing. 5. Your Project Development Plan will be evaluated per the standards set forth in the Land Use Code (LUC) and the Ladmer County Urban Area Street Standards (LCUASS). 6. The entire Fort Collins Land Use Code is available for your review on the web at hftp://www.colocode.com/fteollins/landuse/begin.htm. 7. The Lahmer County Urban Area Street Standards are online at hftp://www.larimer.or.q/engineering/GMARdStds/UrbanSt.htm. 0 City Of CONCEPTUAL REVIEW Fort Collions STAFF COMMENTS 6. of any utility or grading work on the site a Development Construction Permit (DCP) may need to be issued. This permit is issued by Engineering. 7. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 8. The project shall be designed in accordance with the Larimer County Urban Area Street Standards (as applicable). The Larimer County Urban Area Street Standards can be found online at: hftp://www.larimer.or_q/engineering/GMARdStds/UrbanSt.htm. 9. The existing concrete driveway on Myrtle Street will need to be reconstructed or closed. *It will be closed to enhance the overall streetscape and add an additional five parking spaces to the street parking. 10. If the alley needs to be significantly cut and trenched for new utility service connections, the alley may need to be fully reconstructed with an approved, engineered design that works with the alley to the north. *Power has existing sleeves under the alley. No disturbance is planned in the alley pavement. HISTORIC PRESERVATION Contact Info: Alyson McGee, 221-6697, amcgee(cDfcgov.com 1. In February 2007 it was determined that the dwelling unit located at 318 W. Myrtle St. is not individually eligible for historic landmark designation. The house located at 320 W. Myrtle St. was determined to be individually eligible for local landmark designation. A determination has not been made for the garage at 318 W. Myrtle St., so the applicant will need to submit photos of MIA sides of the structure for a determination of eligibility before the structure can be demolished. *There are no physical changes planned at this time for 320 W. Myrtle. Photos of the garage are part of this submittal. 2. Section 3.4.7 of the Land Use Code calls for the development plan and building design to protect and enhance the historic and architectural value of any historic property adjacent to the site. Please work with Historic Preservation staff to design the new structures in a character that complements the existing historic structures. Financial assistance may be available for renovations if you choose to designate the house at 320 W. Myrtle St. *The new structures complement the existing structure @ 320 W. Myrtle in the following manner: 7 City of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS Trash enclosures should be designed to be compatible with the building architecture and should be large enough to accommodate recycling services. * A trash/recycling center will be provided adjacent to an existing trash area for the property north of this site 3. Please contact Dana for information about Green Building programs and services offered by the City. ELECTRIC UTILITY Contact Info: Bruce Vogel, 221-6700, utilities(a)-fcgov.com 1. The existing transformer located at the comer of Myrtle and Meldrum Streets may be adequate to carry the load for this proposal. If not, a larger transformer will be required and the developer is responsible for the cost of replacement. Normal Development Fees and System Modification charges may apply and more information about these fees can be found online at http://fcgov.com/utilities/rates-fees.php. Please contact Doug Martine at 224-6152 to discuss development charges and service requirements. * An existingtransformer across the alley @ the North East corner of the lot will service the site . A utility easement will be required from the property d"rrectly north of this lot ENGINEERING Contact Info: Randy Maiziand, 221-6605, rmaizland(ab-fcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees for this project will apply and be due at the time of building permit. Please contact Matt Baker (970-224-6108) if you have questions about the Street Oversizing Fees. 2. Transportation Development Review Fees (TDRF) will apply to this project and are due at the time of submittal. For more information, visit http://fcgov.com/engineering/dev-review.php. 3. A Transportation Impact Study (TIS) may need to be submitted with this project. Please contact Traffic Operations (Joe Olson or Ward Stanford) at 221-6630 to discuss TIS requirements and/or to schedule a scoping meeting. 4. This project will need to prepare and submit utility plans. 5. The City will enter into a development agreement with the developer for this project. A City Of CONCEPTUAL. REVIEW Fort Collions STAFF COMMENTS 3. �lRf�tfe� and water rights will be due at building permit. More information about these fees can be found online at hftp:/tfcqov.com/utilities/rates-fees.php. POUDRE FIRE AUTHORITY Contact Info: Carle Dann, 416-2869, cdannCaD-poudre-fire.org 1. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum of 6 inch numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). An address kiosk would be helpful for non -street fronting dwelling units. 97UFC901.4.4 *Numerals will be six inches 2. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum requirements include: • Residential: 1,500 gpm (a flow test should be conducted to determine if the existing hydrant at Myrtle/Meldrum can adequately serve the property) These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2 * Flows in the area are adequate for this type of development 3. AUTOMATIC FIRE SPRINLKERS Automatic Fire Sprinklers may be required with the adoption of a new Fire Code for any residential project with more than 2 dwelling units. Please contact Care for current code requirements and information about when the new code may be adopted. * Automatic fire sprinklers will be installed ENVIRONMENTAL PLANNING Contact Info: Dana.Leavitt, 221-6143, dleavittCcDfcgov.com 1. Please contact .Tim Buchanan, City Forester, at 221-6361 for an evaluation of the trees on the property. Existing trees that are deemed significant will need to be protected or if they are removed, they will need to be replaced with mitigation trees. *A site visit with Tim Buchanan has occurred and all trees were considered insignificant and not worth saving. A large elm will remain at the entrance to the new parking area. An Existing Locust tree In the front will remain. 5 City Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS ATER UTILITY Contact Info: Glen Schlueter, 224-6065, gschlueter(a_fcgov.com 1. The amount of new impervious area will affect the Stormwater "new development fee" and the submittal requirements for redevelopment. The existing impervious areas are grandfathered; therefore, documentation is needed with a site plan showing existing and proposed impervious areas along with a table listing each area and showing the final amount of new imperviousness. *Table is included on drawings and as a separate submittal item 2. In the Old Town drainage basin, a drainage and erosion control report and construction plans are required if there is an increase in imperviousness greater than 5000 square feet. These must be prepared by a Professional Engineer registered in Colorado. *The new impervious area is less than 5000 S.F. 3. If there is an increase in imperviousness greater than 5000 square feet, onsite detention is required with a 2 year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. Water quality treatment is encouraged as described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). However, this site does drain to the Udall Natural Area which does treat the runoff so there is not a requirement for onsite wfater quality treatment. If there are less than 5000 but more than 350 square feet of new imperviousness, a site grading plan is all that is required. *New grading plan is part of site plan 4. There is a storm sewer in Myrtle should there be a need for a deeper outlet than the street or alley. 5. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Design Criteria and Construction standards. 6. The city wide development fee is $4,420/acre ($0.1015/sq.ft.) for new impervious area over 350 sq.ft. No fee is charged for existing impervious area. This fee is to be paid at the time each building permit is issued. WATER & WASTEWATER Contact Info: Roger Buffington, 221-6854, rbuffington(cD_fcgov.com 1. Existing mains: 4-inch water main in Myrtle; 8-inch sanitary sewer in alley east of site. *The sanitary service for 318 W. Mytle will service the additional units. 2. The two existing residences on the property each have a %-inch water service. A %-inch service for a 4-plex may be marginal. Provide service sizing calculations. *There will be a new 1" service from Myrtle St. 4 City/ Of 0 CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS Off-street parking or residential uses is not required in the TOD Overlay zone district; however, off-street parking is highly recommended in this area. *There are eight off street parking spaces which includes a hadicaped space. 5. Minimum lot area shall be equivalent to the total floor area of the building(s), but not less than five thousand (5,000) square feet for . each principal building. *Lot area is 14,250 square feet and finished square footage of new and existing buildings total 6,310 square feet. 6. Lots are subject to a maximum FAR of thirty-three hundredths (0.33) on the rear fifty (50) percent of the lot. * rear of lot allows 2,375 S.F. proposed is 2,156 7. Minimum lot width shall be forty (40) feet for each single-family and two-family dwelling and fifty (50) feet for each other use. If more than one (1) principal building is proposed to be constructed side -by -side on the same lot, then each such principal building must have at least forty (40) feet of street frontage for single-family and two-family dwellings, and at least fifty (50) feet of street frontage for each other use. *The lot has 95 feet of frontage and 90 feet is required 8. Minimum front yard setback shall be fifteen (15) feet * The existing principal building is 7'-9" off of property line. The _remodel of 318 W. Myrtle will add another 4'-0" of set back. 9. Minimum rear yard setback shall be five (5) feet from existing alley and fifteen (15) feet in all other conditions. *The proposal meets requirements 10. Minimum side yard width shall be five (5) feet for all interior side yards. Whenever any portion of a wall or building exceeds eighteen (18) feet in height, such portion of the wall or building shall be back from the interior side lot line an additional one (1) foot, beyond the minimum required, for'each two (2) feet or fraction thereof of wall or building height that exceeds eighteen (18) feet in height. *The existing principal building is 1.5 feet off side setback. All new construction conforms to side setbacks and height restrictions. A modification to standards is submitted. 11. Maximum building height shall be three (3) stories. *meets requirements, low eave heights are planned and are less than a typical two story eave height. 12. A modification to the minimum side yard width standard will need to be requested if the remodeled dwelling unit at 318 W. Myrtle does not comply with minimum side yard requirements. * Modification is submitted within. 13. Parking lot perimeter and interior landscaping will be required per Section 3.2.2 of the Land Use Code. * See landscape drawing 3 City/ Of CONCEPTUAL REVIEW Fort Collins STAFF COMMENTS ITEM: Proposed remodel of the dwelling unit at 318 W. Myrtle plus addition of three attached dwelling units on the lot at 318 and 320 W. Myrtle St.. * New proposal contains an additional attached unit. MEETING DATE: July 28, 2008 APPLICANT: Bruce Froseth Susan Kreul-Froseth 524 Spring Canyon Ct. Fort Collins, CO 80525 brucefroseth(cDmsn. com archfro(a)earthlink. net LAND USE DATA: The property is located on north side of West Myrtle Street between South Meldrum Street and South Howes Street, adjacent to the north - south alley. There are two dwelling units on the property and a garage that is proposed to be demolished. COMMENTS: The following departmental agencies have offered comments for this proposal based on a sketch plan and project narrative which were presented to the review team: ZONING Contact Info: Peter Barnes, 416-2355, pbames(aD_fc4ov.com 1. The property is located in the NCB — Neighborhood Conservation Buffer zone district. Information about this zone district can be found online at: hftp://www.colocode.com/ftcollins/landuse/article4.htm#div4d9. 2. Multi -family dwelling units located within a street -fronting principal building are permitted residential uses in this zone, subject to Administrative (Type 1) review and public hearing approval. The proposed three new dwelling units need to be attached to the existing dwelling unit at 318 W. Myrtle in order to comply with the °street - fronting principal building" requirement. *The new dwellings are attached 3. This property is also located in the Transit Oriented Development (TOD) Overlay zone district. Information about this district can be found online at: hftp://www.colocode.comtftcollins/landuse/article3.htm#div3d 10. 2