Loading...
HomeMy WebLinkAboutFRONT RANGE VILLAGE, 2ND REPLAT - PDP - 12-09 - CORRESPONDENCE -If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D Number: 3 Created: 3/27/2009 LOT 1 VS. LOT 2: The EAE for Lot 2 (Compass Bank, 2640 E. Harmony Road) is acceptable. Normally, we do not allow a dead-end fire access road longer than 150 feet to not have a turn -around. However, I have spoken on numerous occasions with developer representatives and we can allow the additional length in the EAE because (1) the easement needs to be long in order to accommodate the location of the building and (2) apparatus will be able to turn around on the site. However, Lot 1 may need to be replatted in the future, since there are no structures shown and it is impossible to determine where or if an EAE would be needed. Number: 4 Created: 3/27/2009 Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 5 Created: 3/30/2009 [3/30/09] Please change the easement on the north side of Lot 2 to Drainage and Utility. The Replat is ready for the Administrative public hearing. Current Planning will advise you as to the exact date, time and location. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. SiTncerely- Ted Shepard Chief Planner Page 2 STAFF PROJECT REVIEW City of Port Collins GAYER PROPERTIES, LLC P 11. E Date: 4/6/2009 2222 ARLINGTON AVE �c22 — J 7 BIRMINGHAM, AL 35205 Staff has reviewed your submittal for FRONT RANGE VILLAGE 2ND REPLAT PDP- TYPE I, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Marc Virata Topic: General Number: 7 Created: 3/31 /2009 [3/31/091 Please add ' Village" after "The Front Range" at the start of note #3. Number. 8 Created: 3/31 /2009 [3/31/09] Please note that this replat must be recorded before or concurrently with the approval of the minor amendment for Compass Bank as the recordation of the plat establishes the legal right to construct aspects of the Compass Bank plans. Number: 10 Created: 3/31 /2009 [3/31/091 Technical Services has some concerns, see redlines and comments. Department: Light & Power Issue Contact: Janet McTague Topic: General Number: 6 Created: 3/31 /2009 [3/31/091 Light and Power has no problems but only as long as the existing vault doesn't have to be relocated. If relocation is necessary, it will be at the expense of the developer. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 2 Created: 3/27/2009 REQUIRED ACCESS: Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: ❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ❑ Have appropriate maintenance agreements that are legally binding and enforceable. ❑ Be designated on the plat as an Emergency Access Easement. ❑ Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structures is three or more stories in height). Pai7e 1