HomeMy WebLinkAboutMIDTOWN ARTS CENTER (3750 S. MASON ST.), CHANGE OF USE - PDP - 1-10/A - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWPlease contact Dana, at 224-6143, if you have questions about these comments. 9. This development request will be subject to the Development Review Fee Schedule that is available in the Development Review Center office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. Understood 10. This development proposal is subject to all the requirements set forth in the City's LUC, specifically Article 2. Administration (Development Review Procedures), Article 3. General Development Standards, and Article 4. Districts (specifically Division 4.21 - Commercial District). The proposed uses will be subject to a Planning & Zoning Board (Type 2) review and public hearing. There are Land Use Standards, Development Standards, and Development Standards for the Transit -Oriented Development (TOD) Overlay Zone specific to the C District that development on this property will be subject to. Copies of Article 3 and Division 4.21 are available in the Development Review Center or on the City of Fort Collins website @ www.fcgov.com. Go to Departments, then the Current Planning Department. 11. The City's Current Planning Department will coordinate the development review process. The required submittal package will be submitted to the Development Review Center, 281 North College Avenue, and distributed accordingly to other City departments and outside reviewing agencies involved in development review. The submittal requirements for Project Development Plans and Final Compliance Plans are available on the City's website. End of responses. Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 8 of 8 2006 International Fire Code 1004.3 Understood COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM With the production of grease -laden vapors, an approved, automatic fire - extinguishing system shall be provided for the protection of commercial -type cooking equipment. 2006 International Fire Code 904.2.1; 609.2; 90411.2 Understood KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box') to be mounted in approved location(s) on every new building equipped a required fire -sprinkler system or fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 To be included if required based on item 6(b) above Please contact Carie, at 416-2869, if you have questions about these comments. 7. Jennifer Petrik of the Transportation Planning Department offered the following comments: a. Bicycle Parking is required. Bicycle parking should be convenient to the entrance for both employees and visitors, on a hard surface and out of the elements if possible. Understood b. No change in the sidewalk is required at this time. Please contact Jennifer, at 416-2471, if you have questions about these comments. 8. Dana Leavitt, the City's Environmental Planner, offered the following comments: a. For any changes to the interior building system consider deconstruction versus demolition. Contact John Armstrong at 416-2230 for more information on deconstruction programs. This option will be considered. b. The Integrated Design Assistance Program (IDAP) is available to all business/commercial customers of Fort Collins Utilities for assistance in developing energy efficient/conservation alternatives for new and retrofit projects. Gary Schroeder can be reached at 221-6395 for more information on this highly regarded program. Energy savings realized within the first year quite often off set initial up front costs. IDAP funds are available for assistance during the design phase of the project. Understood C. More information about the City's Green Building Program can be found at the following website: http://www.fcclov.com/greenbuilding/ d. Review the many programs available to you for cost savings during the design construction and then use of the building. Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 7 of 8 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B Understood e. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 2006 International Fire Code 505.1 Understood IDENTIFICATION OF FIRE PROTECTION EQUIPMENT Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, electrical rooms, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. 2006 International Fire Code 510.1 Understood g. PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be installed in the following locations: 1 . New buildings greater than 50,000 SF in size or addition(s) to an existing building that cause the building to be greater than 50,000 SF. For the purpose of this section, fire walls shall not be used to define separate buildings. The existing building is less than 50,000 sf 2. All new basements greater than 10,000 SF where the designed occupant load is greater than 50, regardless of the occupancy classification. The existing building does not have a basement. 3. Existing buildings meeting the criteria of Items 1 and 2 of this section undergoing alterations exceeding 50 percent of the aggregate area of the building. The existing building does not meet the criteria of Items 1 and 2 of this section. Public -safety radio amplification systems shall be designed and installed in accordance with criteria established by Poudre Fire Authority. PFA Fire Prevention Bureau Administrative Policy 07-01 Will not be required based on the above criteria h. OCCUPANT LOAD SIGN Any room or space having an occupant load of 50 or more and which is used for assembly purposes, shall have the capacity of the room posted in a conspicuous place on an approved sign near the main exit or exit access doorway from the room or space. Such sign shall be maintained legible by the owner or the owner's authorized agent and shall indicate the number of occupants permitted for each room use. Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 6 of 8 fire -sprinkler system. PFA records show that this structure already has a fire sprinkler system. 2006 International Fire Code New Table 903.1 and Section 702 The structure has fire sprinklers on the mezzanine which will be supplemented as required. The applicant proposes that sprinklers not be required on the ground floor based on the existing construction type (type III 1 hr.) and since the existing and proposed exiting configurations will provide nearly double the required exits based on the combined A-1 and A-2 uses. This issue will be addressed further as the design progresses. C. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: ➢ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ➢ Have appropriate maintenance agreements that are legally binding and enforceable. ➢ Be designated on the plat as an Emergency Access Easement. ➢ Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire - sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D. The existing site access and fire lanes are in conformance with the above and will be maintained. d. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800- foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 5 of 8 b. The existing impervious area is grandfathered, and there aren't any new impervious areas being proposed. If that changes and there is an increase in impervious area greater than 1,000 square feet, a drainage and erosion control report and construction plans are required and must be prepared by a Professional Engineer registered in Colorado. A grading plan is required when there is between 1,000 and 350 square feet of new impervious area, but no drainage study is required. No new impervious area is proposed. C. If there is an increase in impervious area greater than 1,000 square feet, onsite detention is required with a 2 year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. If there is less than 1,000 but more than 350 square feet of new impervious area, a site grading plan is required along with the impervious area documentation. No new impervious area is proposed. d. The design of this site must conform to the drainage basin design of the Mail Creek Master Plan Update as well the City's Design Criteria and Construction standards. In a telephone conversation between Applicant's Civil Engineer Glen Owen and Glen Schlueter on 1.3. 2010, this issue was addressed. A civil engineering report on proposed methods and strategy is in process and the applicant will submit as requested by January 8. e. The City-wide development fee is $4,420/acre ($0.1015/sq.ft.) for new impervious area over 350 sq.-ft. No fee is charged for existing impervious area. This fee is to be paid at the time each building permit is issued. Understood Please contact Glen, at 224-6065, if you have questions about these comments. 6. Carie Dann of the Poudre Fire Authority offered the following comments: a. OCCUPANCY TYPE Fire Code comments are based on numerous factors, the main one being Occupancy Classification. If there is a change in occupancy classification, then the structure must be brought up to current code. Based on the information given, the renovation would contain an A-1 Occupancy (Assembly - theater) and a B occupancy (Business — educational academy). The previous tenant was also an Al ; I'm not sure if it also had a B classification. Ultimately, the occupancy types will determine whether PFA can specify new requirements. All proposed occupancies will be either A-1 or A-2. b. AUTOMATIC FIRE SPRINKLERS Proposed structures may be required to be equipped with approved automatic fire -sprinkler systems, depending on occupancy type, construction type, building size, emergency -vehicle access, water supply and other factors. PLEASE NOTE: The 2006 International Fire Code specifies that A-1 Occupancies with an occupant load of 300 or more, or that contain a multi - theater complex (among other conditions) is required to have an automatic Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 4 of 8 appear to be needed for this project. This may change subject to the discovery of needing to build public infrastructure outside of the building. Please contact Marc, at 221-6567, if you have questions about these comments. 3. Janet McTague of the Light & Power Department offered the following comment: a. No comments as there are no anticipated changes to the electrical at this time Please contact Janet, at 224-6154, if you have questions about this comment. 4. Roger Buffington of the Water/Wastewater Department, offered the following comment: a. If meals for the dinner theater are prepared onsite, a grease interceptor will be required on the drain lines from the kitchen area. In addition, the meal preparation places this use in the restaurant category for wastewater development fees. The additional fees (at the 2009 rate) due for the restaurant use are $25,794 which will be due at time of building permit. These fees will be increasing at the beginning of 2010. Per discussion with Roger Buffington on 1.3.2010, a Utility plan is not required for this application as no site or utility modifications are planned. The project proposes limited food service of approximately 700 plates per week for the Dinner Theater and occasionally (two to three times per month) up to 200 plates for the small scale reception center. No fried foods will be offered in the proposed project. Please refer to the attached letter from the applicant detailing the cooking practices and copy of the dinner theater menu for further detail with respect to this topic. We are working with engineer Mark Taylor at this city and all issues will be resolved prior to building permit issuance. Please contact Roger, at 221-6854, if you have questions about this comment. 5. Glen Schlueter of the Stormwater Utility offered the following comments: a. Since the site needs to be updated to conform to the Land Use Code (LUC) for the change -of -use, the site drainage system needs to be modified to treat the runoff. Water quality treatment methods are described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). Please have the design engineer contact Stormwater staff to discuss their proposed methods of water quality treatment. As discussed, the water quality treatment methods could be shown on the site plan so that a separate construction plan set is not needed. In a telephone conversation between applicant's Civil Engineer Glen Owen and Glen Schlueter on 1.3. 2010, Schlueter indicated that the City will not require "full' water quality improvements; however "something" will need to be done in order to help the City stay in compliance with the Municipal Storm Water Regulations imposed by the Clean Water Act. A civil engineering report on proposed methods and strategy is in process and the applicant will submit as requested by January 8. Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 3 of 8 Since all of the parking currently is located between the building and the two streets, a modification of this standard would be required. Since we don't have a detailed site or landscape plan presented at this time, its not know what other upgrades to the parking lot and landscaping might also be required. The proposed project changes the building use but does not modify the existing building envelope or impact the site in any way. Modification of the building location or revision of the parking configuration would render the proposed reuse economically infeasible. In fact, even though many of the standards are met by the existing building, the proposed use should be exempted from the standards of the TOD Overlay Zone in Division 3.10 of the LUC based on Section 2.8.2 (H) standards (2) and (4) of the LUC as addressed in the Modifications of Standards request attached to this Project Development Plan Application. Please contact Gary, at 416-2338, if you have questions about these comments. 2. Marc Virata of the Engineering Department offered the following comments: a. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 to discuss what may be anticipated for these fees. In addition, Matt can verify whether any repays may be due to the City for the existing infrastructure. Understood b. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see http://www.fcaov.com/engineering/dev-review.php Understood C. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. Understood d. Please contact Joe Olson, the City's Traffic Engineer, at 224-6062, and Jennifer Petrik of Transportation Planning, at 416-2471, to schedule a scoping meeting and determine if a traffic study is needed for this project. Per a telephone conversation and follow-up email with Joe Olson on 12.30.2009: (The City) "will not require a traffic impact study related to motor vehicle impacts for the proposed relocation of the Carousel Dinner Theater to the existing building at 3750 S. Mason. We do not anticipate any increase in trip generation compared to previous uses at that building. Therefore, no study is required." e. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). Understood. Based upon current information, utility/public improvement plans, a development agreement, and a Development Construction Permit, all do not Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 2 of 8 Conceptual Review Letter Responses January 5, 2010 Midtown Arts Center (Previously the Mann Theatre Building at 3750 S. Mason St.) City Conceptual Review Letter Comments shown in BLACK Applicant Development Review Responses shown in GREEN MEETING DATE: November 9, 2009 ITEM: The Mann Theatre Building at 3750 South Mason Street APPLICANT: Sperry Van Ness c/o Robert V. Hau 2020 Caribou Drive, Suite 201 Fort Collins, CO. 80525 Kurt Terrio KT Productions Inc. 3509 S. Mason St. Fort Collins, CO 80525 LAND USE DATA: Request for an "Entertainment Facility and Theater", a "Small Scale Reception Center", and a "Private School" in the existing building at 3750 South Mason Street (formerly the Mann Theatre). The applicant plans to renovate the building to accommodate a dinner theater, performing arts academy, presentation theater and multi -purpose room/Black Box. It will also include a kitchen. The property is in the C, Commercial District. The proposed uses have been revised as follows: Dinner theater, presentation theater, small scale reception center, multi -purpose room/black box theater and kitchen. COMMENTS: Gary Lopez of the Zoning Department offered the following comments: a. The property is zoned C, Commercial. b. Use would be classified as "Entertainment Facility and Theater" and "Private School". Both uses are allowed in the C District as a Planning & Zoning Board (Type 2) review and public hearing. A third use will also be required for the receptions, etc., which is called Small Scale Reception Center. "Private School" has been removed from the proposed uses. C. The change -of -use requires that the site be brought into compliance with the applicable regulations of Articles 3 and 4 of the Land Use Code (LUC), which includes compliance with standards for the Transit -Oriented Development (TOD) Overlay Zone in Division 3.10 of the LUC. One issue would be the requirement that parking can't be allowed between the building and a street. Conceptual Review Letter Responses: Midtown Arts Center Prepared by RB+B Architects page 1 of 8