Loading...
HomeMy WebLinkAboutPURA VIDA PLACE - FDP - FDP110006 - CORRESPONDENCE -Ciof Flirt Collins STAFF PROJECT REVIEW Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: Construction Drawings Number: 3 Created: 05/31 /2011 05/31/2011: No grease interceptor needed. Remove Standard Details. Be sure to return redline plan sheets when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to contact me at 970-221-6343. Sincerely, Ted Shepard Chief Planner Cf Fort Collins STAFF PROJECT REVIEW Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Number: 4 Created: 05/31/2011 05/31/2011: Please add additional spot elevations per redlines. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Number: 5 Created: 05/31/2011 05/31/2011: We were not routed plans. We will need to review them next round. Topic: Construction Drawings Number: 6 Created: 05/31/2011 05/31/2011: There are line over text issues on sheets 3-6. Number: 7 Created: 05/31/2011 05/31/2011: Please change the "100' ROW" for Laurel Street on sheets 3-6, to "ROW Varies". The ROW width of Laurel is in question. Topic: Landscape Plans - - - ----- Number:-4- — -- -- — -- ---- -- - - -- --------- - --Created:-05/31/2011- - 05/31/2011: There are line over text issues. Topic: Plat Number: 1 Created: 05/31/2011 05/31/2011: The Subdivision Plat has some very bold text on sheet 2. We have talked with the Surveyor, and this is a "PDF" problem. Topic: Site Plan Number: 2 Created: 05/31/2011 05/31/2011: Please change "Description" to "Legal Description" on sheet Al. 1. Number: 3 Created: 05/31/2011 05/31/2011: There are line over text issues on sheet Al. 1. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: Construction Drawings Number: 1 Created: 05/31/2011 05/31/2011: On 3-inch water services, the valve at the connection to the City water main serves as the City's control valve; therefore, no curb stop is needed. Number: 2 Created: 05/31/2011 05/31/2011: Label the clean -out on the sewer service in the parking area as "traffic -rated".; Fort Collins STAFF PROJECT REVIEW 06/02/2011: Sheet L1.0 only needs to show 150' offsite (same with the site plan) so you can reduce the off -sites shown and enlarge your drawing. This will help with legibility and scannability issues. Department: Engineering Development Review Contact: Susan Joy, 970-221-6581, sjoy@fcgov.com Topic: Landscape Plans Number: 32 Created: 06/02/2011 06/02/2011: Sheet L2.0 is only showing a portion of the site. Where is the other half? Also, please provide key maps on the upper right hand corner whenever you break up the areas being shown. Topic: Site Plan Number: 22 Created: 06/01 /2011 06/01/2011: Repeat Comment- Please remove all revisions from the revision block. This is not an approved plan set being revised and this area will stay blank until that should happen in the future. Number: 23 Created: 06/02/2011 06/02/2011: Repeat Comment - This plan set must be in an engineering scale. Number: 24 Created: 06/02/2011 06/02/2011: All easements must be labeled as existing or proposed and all easements must be shown, labeled and dimensioned. Department: PFA Contact: Carie Dann, 970-219-5337, CDANN@poudre-fire.org Topic: General Number: 1 Created: 05/31/2011 05/31/2011: PFA has no additional comments or concerns at this time. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarque@fcgov.com Topic: General Number: 1 Created: 05/31/2011 05/31/2011: Please add spot elevation markers and remove spot elevation I.D.s. Number: 2 Created: 05/31/2011 05/31/2011: Please add details fort the concrete pan and channel. Number: 3 Created: 05/31/2011 05/31/2011: Please provide a 1-foot radius for the channels at the curb along Laurel St. See redlines. Citypf Fort Collins STAFF PROJECT REVIEW Number: 20 Created: 06/01/2011 06/01/2011: The Engineer's Affirmation Statement only has to be shown once on the cover sheet. You can continue to have it on each sheet but it's not required. Department: Engineering Development Review Contact: Susan Joy, 970-221-6581, sjoy@fcgov.com Topic: Construction Drawings Number: 21 Created: 06/01/2011 06/01/2011: Grading Sheet - The spot elevations shown do not have a "spot", in other words, there is an elevation called out but I can not tell where the elevation is located. At this point, I can not tell if spots are called out at all lot corners. Topic: General Number: 18 Created: 06/01/2011 06/01/2011: Please see Tim Buchanan with Forestry to discuss the sidewalk chase and utility locations as they relate to the existing trees. He can be reached at tuchanan@fcgov.com or you may call him at 221-6361.and leave as blank. Number: 33 Created: 06/02/2011 06/02/2011: We might want to meet and go over the plans before resubmitting so that we can make sure you get a clean submittal with the next go around. Please email me at sjoy@fcgov.com as soon as your ready to set up a meeting. -- — - Topic: --Landscape Plans ---- --- ----- - ------ — --- — Number: 25 Created: 06/02/2011 06/02/2011: Repeat Comment -Please remove all revisions from the revision block. This is not an approved plan set being revised and this area will stay blank until that should happen in the future. Number: 26 Created: 06/02/2011 06/02/2011: Repeat Comment - This plan set must be in an engineering scale. Number: 27 Created: 06/02/2011 06/02/2011: All easements must be labeled as existing or proposed and all easements must be shown, labeled and dimensioned. Number: 28 Created: 06/02/2011 06/02/2011: Please show all utilities. Number: 29 Created: 06/02/2011 06/02/2011: Please see Appendix E6 for all scanning requirements. Line over text issues. Text too small in some areas and not meeting minimum grey scale requirements. Use grayscale for existing features and a dark lineweight for proposed (this is shown backwards on the plan). Number: 30 Created: 06/02/2011 06/02/2011: Please place the sight distance note shown on the plat on the plans and make sure that all landscaping proposed within it meets the criteria within it. Number: 31 Created: 06/02/2011 Cft Fort Collins STAFF PROJECT REVIEW Department: Engineering Development Review Contact: Susan Joy, 970-221-6581, sjoy@fcgov.com Topic: Construction Drawings Number: 9 Created: 06/01/2011 06/01/2011: All Sheets - Still need to show, label and dimension all easements and row on all sheets. Number: 10 Created: 06/01/2011 06/01/2011: Sheet 5 - Note 13, please add that final limits of asphalt removal in the alley are to be determined by the city inspector and then refer to the city4s street cut note that I asked you to add. Number: 11 Created: 06/01/2011 06/01/2011: Sheet 5 - Need to dimension the length of the depressed curb. Number: 12 Created: 06/01/2011 06/01/2011: Sheet 6 -This sheet still has legibility and scanning issues. Please remove all landscaping and correct all line over text problems. Please see Appendix E6 for all - — — ----scan ning-requirements and -bring -the entire plan -set up to standard -We cannot sign the -"---- --- mylars until scanning requirements are met. Number: 13 Created: 06/01/2011 06/01/2011: Sheet 6 -Please remove the note at the bottom of the page. This is already covered by LCUASS and our street cut note and rather than possibly wording this note in such a way that it creates a conflict, I prefer it to be taken off completely. Number: 14 Created: 06/01/2011 06/01/2011: Sheet 6 - Please provide more spots and drainage arrows so we can see whether or not your proposed fix to solve the drainage problem in the alley works. If providing a profile would help convey your design, then please add one. Number: 15 Created: 06/01/2011 06/01/2011: All Sheets -Please remove landscaping information. In fact, take landscaping off all sheets unless you need to show an existing tree that needs to be protected. I think taking off the landscaping will help you meet the scanning requirements too. Number: 16 Created: 06/01/2011 06/01/2011: Sheet 9 - Remove all Figures. These are for design purposes only and are not details to be constructed from. Number: 17 Created: 06/01/2011 06/01/2011: Sheet 9 - Label all private improvements as "private" or "onsite". Number: 19 Created: 06/01/2011 06/01/2011: Please add detail 702. Cftyof F6rt Collins STAFF PROJECT REVIEW June 06, 2011 Charles Bailey Catamount Properties Ltd 7302 Rozena Drive Longmont, CO 80503 City staff and outside reviewing agencies have reviewed your submittal for Pura Vida, and we offer the following comments: Department: Engineering Development Review Contact: Susan Joy, 970-221-6581, sjoy@fcgov.com Topic: Construction Drawings Number: 1 Created: 06/01/2011 06/01/2011: Cover Sheet - Legal description must match the one on the plat. Number: 2 Created: 06/01/2011 06/01/2011: Cover Sheet - Please update the month to current. Number:-3------.---..---------------_____.__Created:--06/01/2011---- 06/01/2011: Index --Still says that a copy ofthe plat and the alta survey has been included. They are still not in the set so either add them or take the items off of the Index. Number: 4 Created: 06/01/2011 06/01/2011: General Notes, Line 48 - add "NA" Number: 5 Created: 06/01/2011 06/01/2011: Sheet 3 - Need to show the offsite sidewalk removal to the west where you'll need to remove the existing and install the new 6' tapered section. Number: 6 Created: 06/01/2011 06/01/2011: Sheet 4 - It appears that the channel running along the east side of the trash enclosure is extended into the alley. Please pull it back out of public row or explain why this has been done so I can evaluate that. Number: 7 Created: 06/01/2011 06/01/2011: All Sheets - Whenever referring to a detail on another sheet, call out the detail # and the sheet #. Number: 8 Created: 06/01/2011 06/01/2011: Add the street cut note to sheets 3, 4, 5 and 6: Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards.