HomeMy WebLinkAboutPURA VIDA PLACE - FDP - FDP110006 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEWPROJECT: Pure Vida BUILDING: CODE: IPC 2009 DATE: 1/21/2011 FIXTURE TOTAL FIXTURE TYPE WATER FIXTURE UNITS WASTE FIXTURES UNITS REMARKS COLD WATER COLD TOTAL HOT WATER HOT TOTAL COLD 8 HOT COMBINED TOTAL FOCTURE VALUES TOTAL VALUES OCC. SUPPLY TYPE 99 BATHROOM GROUP PRIVATE FLUSH TANK 2.70 267.3 1.50 148.5 3.60 356.4 5.00 495.0 BATHROOM GROUP PRIVATE FLUSH VALVE 6.00 0.0 3.00 0.0 8.00 0.0 5.D0 0.0 BATHTUB OR COMBINATION BATWSHOWER PRIVATE FAUCET 1.00 0.0 1.00 0.0 1.40 0.0 2.00 0.0 BATHTUB OR COMBINATION BATH/SHOWER PUBLIC FAUCET 3.00 0.0 3.00 0.0 4.00 0.0 2.00 0.0 BIDET PRIVATE FAUCET 1.50 0.0 1.50 0.0 2.00 0.0 1.00 0.0 COMBINATION FIXTURES PRIVATE FAUCET 2.25 0.0 2.25 0.0 3.00 0.0 2.00 0.0 4 HOSE BIBBS PRIVATE 1/2' VALVE 2.50 10.0 0.0 2.50 10.0 0.0 HOSE BIBBS ADDITIIONAL PRIVATE 1/2' VALVE 1.00 0.0 0.0 1.00 0.0 1 0.0 DRINKING FOUNTAIN OFFICES 3/8' VALVE 0.25 0.0 0.0 0.25 0.0 0.50 0.0 52 KITCHEN SINK PRIVATEI FAUCET 1.00 52.0 1.00 52.0 1.40 72.8 2.00 104.0 KITCHEN SINK HOTEL FAUCET 3.00 0.0 3.00 0.0 4.00 0.0 2.00 0.0 52 DISHWASHER PRIVATE AUTOMATIC 0.0 1.40 72.8 1.40 72.8 2.00 104.0 LAUNDRY TRAYS 1 TO 3 PRIVATE FAUCET 1.00 0.0 1.00 0.0 1.40 0.0 2.00 0.0 LAVATORY PRIVATE FAUCET 0.50 0.0 0.50 0.0 0.70 0.0 1.00 0.0 LAVATORY PUBLIC FAUCET 1.50 0.0 1.50 0.0 2.00 0.0 1.00 0.0 SERVICE SINK OFFICES FAUCET 2.25 0.0 2.25 0.0 3.00 0.0 2.00 0.0 BAR SINK PUBLIC FAUCET 0.75 0.0 0.75 0.0 1.00 0.0 2.00 0.0 BAR SINK PRIVATE FAUCET 0.50 0.0 0.50 0.0 0.70 0.0 2.00 1 0.0 3/8' CONNECTION PUBLIC FAUCET 0.0 0.0 0.0 1 0.0 1/2' CONNECTION PUBLIC FAUCET 0.0 0.0 0.0 1 0.0 SHOWER HEAD PUBLIC MIX VALVE 3.00 0.0 3.D0 0.0 4.00 0.0 2.00 1 0.0 SHOWER HEAD PRIVATE MIX VALVE 1.D0 0.0 1.D0 0.0 1.40 0.0 2.00 1 0.0 URINAL PUBLIC 1' FLUSH 10.00 0.0 0.0 10.00 0.0 4.00 1 0.0 URINAL PUBLIC 3/4' FLUSH 5.00 0.0 0.0 5.00 0.0 2.00 0.0 URINAL PUBLIC FLUSH TANK 3.00 0.0 0.0 3.00 0.0 0.50 0.0 52 WASHING MMACHINE 8 LB PRIVATE AUTOMATIC 1.00 52.0 1.00 52.0 1.40 72.8 2.00 104.0 WASHING MMACHINE 8 LB PUBLIC AUTOMATIC 2.25 0.0 2.25 0.0 3.00 0.0 3.00 0.0 WASHING MMACHINE 15 LB PUBLIC AUTOMATIC 3.D0 0.0 3.00 0.0 4.00 0.0 6.00 0.0 WATER CLOSET PRIVATE FLUSH VALVE 6.D0 0.0 0.0 6.00 0.0 4.00 0.0 WATER CLOSET PRIVATE FLUSH TANK 2.20 0.0 0.0 2.20 0.0 3.D0 0.0 WATER CLOSET PUBLIC FLUSH VALVE 10.00 0.0 0.0 10.00 0.0 4.00 0.0 WATER CLOSET PUBLIC FLUSH TANK 5.00 0.0 0.0 5.00 0.0 4.00 0.0 WATER CLOSET PUBLIC FLUSHMETERTANK 2.D0 0.0 0.0 2.00 0.0 4.00 0.0 TOTAL FIXT. UNITS 381.30 325.30 1 5N.80 I S07.00 I TOTAL FIXTURE UNFTS GPM 100.0 95 140 8' BUILDING MAIN SIZE PIPE SIZE 77 77 3' 1/8' BUILDING MAIN SLOPE WATER SERVICE LINE SIZE 1 FPSEC PSU100FT il NOTES 3'1 5.00 3.00 1$ 1= �► D The narrative explains the reasons why the applicant believes the flat roof meets the criteria for a modification. However, the modification request needs to be a formal request to the planner, not a response in a response -to -comments letter. [2/9/111 per Sec. 4.9(E)(1)(g) of the land use code, a flat pitched roof isn't allowed. Minimum roof pitch must be 2:12 and maximum is12:12. The roof pitch will have to be changed to comply, or a modification will be needed. Response: Per the P&Z Hearing ruling of 4/21/2011, the request for modification of roof pitch was approved. Elevation drawings reflect the approved flat roof design. Topic: Landscape Plans Number: 11 Created: 02/09/2011 03/16/2011: The Plant Materials List shows the species, etc, but the plan itself doesn't label anything. It just has circles, etc showing that something is a tree, shrub, and the like. Response: Plant names, symbols, quantities and totals have been added to the drawings. [2/9/11] Need to label the species of each tree/plant/shrub in the landscape areas. Response: Plant names, symbols, quantities and totals have been added to the drawings. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303,670.5980 • f. 303.670,7162 Department: Traffic Operation Topic: Traffic Impact Study Number: 61 [3/3/11] No Issues. Thank you. Contact: Ward Standard Created: 03/03/2011 Department: Water -Wastewater Engineering Contact: Roger Buffington Topic: Construction Drawings Number: 23 Created: 02/22/2011 03/21/2011: Calculations not received. Will check to see if in the planning file. [2/22/111 Provide water service sizing calculations for the 2-inch domestic water service. Response: A 3 inch domestic water service is now proposed. Also, Please see calculations provided by Given and Associates (MEP) attached. Number: 28 Created: 03/21/2011 03/21/2011: The FDC must connect to the fire line downstream of the backflow preventer which is located inside the building. Acknowledged. Number: 29 Created: 03/21/2011 03/21/2011: Revise the plans and add the note as shown on the redlined plans for the connection of the domestic water service to the existing 8-inch water main. Response: The note as shown on the redlined plans for the connection of the domestic water service to the existing 8-inch water main has been added. Number: 30 Created: 03/21/2011 03/21/2011: On the Demolition Plan, add the existing sewer service stub located west of the MH in the alley and add a note to "Coordinate with Water Utilities (221-6700) and abandon at the main. Response: We've add the existing sewer service stub located west of the MH in the alley and added the requested note to the Master Utility Plan, Master Utility Plan note #6. Number: 31 Created: 03/21/2011 03/21/2011: See redlined plans for other comments. Response: Redlines have been accommodated. Department: Zoning Contact: Peter Barnes Topic: Building Elevations Number: 9 Created: 02/09/2011 03/16/2011: The comment response letter contains a narrative for this comment. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303.670.5980 • f. 303.670,7162 8 1 n Number: 67 Created: 03/04/2011 03/23/2011: There are still line over text issues on the Building Elevations. [3/4/11] There are line over text issues on the Building Elevations. Response: All text has been relocated to accommodate this request. Number: 69 Created: 03/04/2011 03/23/2011: Please change the "names" of the elevation views. See redlines. [3/4/11 ] The elevation view names are confusing. There is no Laurel Court or Alley Court named streets on this project. Response: Names of Courtyard Elevations have been revised to eliminate confusion. Number: 77 Created: 03/23/2011 03/23/2011: Please provide a full size (24"x36") plan for sheet A4.2 of the Elevation Plans. Response: Full Size Elevations have been provided. Topic: Construction Drawings Number: 73 Created: 03/04/2011 03/23/2011: There are still line over text issues on sheets 3, 4, 6 & 7 of the Utility Plans. [3/4/11 ] There are line over text issues on sheet 4 & 6 of the Utility Plans. Response: Plans Sheets have been adjusted due to scanning requirements. Number: 74 Created: 03/04/2011 [3/4/11] The small text on sheet 6 & 8-10 of the Utility Plans, will not reproduce or scan well. Response: Plans Sheets have been adjusted due to scanning requirements where it did not negatively affect readability. Topic: Plat Number: 63 Created: 03/04/2011 03/23/2011: The Subdivision Plat boundary closes. [3/4/111 The Subdivision Plat boundary closes. Number: 64 Created: 03/04/2011 03/23/2011: If this is not a "PDF" issue, please tone down the text. [3/4/11] Please tone down the bold text on sheet 2 of the Subdivision Plat. Response: The bold text is a pdf issue. Final plat, when plotted by Intermill land Surveying, Inc. is a Legible document, with no bold, overbearing text. Topic: Site Plan Number: 65 Created: 03/04/2011 03/23/2011: This comment has not been addressed. [3/4/11] Please add a legal description to the Site Plan. Response: The Legal Description of the Property has been added to the Site Plan. architecture • planning • interiors 1024 cherokee street, suite 200 9 denver, colorado 80204 • p 303.670.5980 9 f. 303.670.7162 minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: - Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter - Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter -Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. PLEASE NOTE: Three hydrants meet the distance requirement: across Laurel Street (Parmalee Hall, and in the northeast quadrant of Laurel and Whitcome streets, and Laurel and Sherwood streets. 2006 International Fire Code 508.1 and Appendix B Acknowledged. Thank you. Number: 1 Created: 03/21/2011 03/21/2011: PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be installed in the following locations: 1. New buildings greater than 50,000 SF in size or addition(s) to an existing building that cause the building to be greater than 50,000 SF. For the purpose of this section, fire walls shall not be used to define separate buildings. 2. All new basements greater than 10,000 SF where the designed occupant load is greater than 50, regardless of the occupancy classification. 3. Existing buildings meeting the criteria of Items 1 and 2 of this section undergoing alterations exceeding 50 percent of the aggregate area of the building. Public -safety radio amplification systems shall be designed and installed in accordance with criteria established by Poudre Fire Authority. PFA Fire Prevention Bureau Administrative Policy 07-01 Number: 2 Created: 03/21/2011 03/21/2011: REMOTE FDC: Please arrange a time to meet me on site to discuss specific location of the remote FDC. Response: Owner team will schedule a meeting to discuss location of remote FDC. Department: Stormwater Engineering Contact: Wes Lamarque Topic: General Number: 23 Created: 03/22/2011 03/22/2011: Stormwater is ready for a hearing. Acknowledged. Thank you. Department: Technical Services Contact: Jeff County Topic: Building Elevations architecture • planning . interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303,670,5980 • f. 303.670.7162 ilk n a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: -Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. -Have appropriate maintenance agreements that are legally binding and enforceable. -Be designated on the plat as an Emergency Access Easement. -Maintain the required minimum width of 20 feet throughout the length of the fire lane (26 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. PLEASE NOTE: We need to address and resolve this issue of emergency vehicle access. The north side of the structure, as well as most of the west and east sides, is out of access due to no drive access to the parking lot. The farthest point of the first -floor exterior is about 250 feet from Laurel Street. We cannot count on the alley as an access point. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D Acknowledged. Thank you. Topic: General Number: 15 Created: 02/22/2011 [2/22/2011] SPRINKLER REQUIREMENTS This proposed building shall be fire sprinklered. 2006 International Fire Code Section 903 Response: This building will be equipped with an NFPA 13 sprinkler system. Number: 17 Created: 02/22/2011 [2/22/2011] KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or fire -alarm system. Knox Boxes are required to be installed approximately 60 inches above grade and no higher than 72 inches above grade. 2006 International Fire Code 506.1 Acknowledged. Thank you. Department: PFA Contact: Carie Dann Topic: General Number: 18 Created: 02/22/2011 [2/22/20111 WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet architecture • planning • interiors 1024 cherokee street, suite 200 • denver. colorado 80204 . p. 303.670.5980 • V 303,670,7162 Number: 67 Created: 03/03/2011 [3/3/11] Add two ornamental street trees on either side of the street light along Laurel. Use Chanticleer Pear or another species recommended by the City Forester. These two ornamental trees should be placed at least 15 feet away from the light. Response: We are proposing additional canopy trees north of the sidewalk to provided the overhead canopy in lieu of ornamental trees as they will continue the canopy provided by the existing historic trees. Department: Light And Power Contact: Doug Martine Topic: General Number: 5 Created: 03/17/2011 03/17/2011: The developer will need to coordinate power requirements and a location for the electric transformer, and the Light & Power development charges with Light & Power Engineering (221-6700). Acknowledged. Number: 6 Created: 03/17/2011 03/17/2011: An AutoCad drawing of the final utility plan will need to be sent to Terry Cox at TCOX(a)FCGOV.COM. Acknowledged. Department: PFA Contact: Carie Dann Topic: Construction Drawings Number: 16 Created: 02/22/2011 [2/22/2011] FIRE DEPARTMENT CONNECTION Fire department connections shall be installed remote from the buildings or in an approved location, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. PLEASE NOTE: PFA will require a remote FDC (not an on -building FDC) be installed near the curbface of Laurel Street. For an idea of what this will look like, there's an example directly across Laurel Street, the FDC servicing Parmalee Hall. 2006 International Fire Code 912.2 and PFA Fire Prevention Bureau Policy Acknowledged. Thank you. Department: PFA Contact: Carie Dann Topic: Easements Number: 14 Created: 02/22/2011 [2/2212011] REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of architecture • planning • interiors 1024 cherokee street. suite 200 • denver, colorado 80204 • p. 303,670.5980 • t 303.670.7162 n n N L14 n Number: 58 Created: 02/28/2011 03/17/2011: Repeat comment. [2/28/11] Must be in Engineering Scale. Response: Site Plan is presented at the scale 1' — 20'-0". Number: Created: 03/17/2011 03/17/2011: Please remove all revision information in the title block. This is not an approved set being revised. Response: All revision information has been removed from the title block. Department: Forestry Topic: Landscape Plans Contact: Tim Buchanan Number: 62 Created: 03/03/2011 [3/3/111 Direct label trees and shrubs as to type on the landscape plan. Response: This has been completed. Number: 63 Created: 03/03/2011 [3/3/11] Show numbers of trees used by type in the Plant Materials List. Response: These are now shown. Number: 64 Created: 03/03/2011 [3/3/11] Follow the minimum species diversity requirement in 3.2.1 (D) (4) Response: This requirement has been met. Department: Forestry Topic: Landscape Plans Number: 65 Contact: Tim Buchanan [3/3/111 Add these note to the landscape plan: Created: 03/03/2011 • A permit must be obtained from the City forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk and curb, medians and other city property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. • Contact the City Forester to inspect all street tree plantings at the completion of each phase of the development. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval of each phase. Response: This has been completed. Number: 66 Created: 03/03/2011 [3/3/111 Add one canopy street tree between the two existing green ash in the parkway along Laurel. Response: This has been completed. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303.670.5980 • f. 303.670,7162 03/17/2011: Repeat comment. [2/28/11 ] Please add the sight distance note from the plat. Response: Sight Distance Note added. Number: 57 03/17/2011: Repeat comment. [2/28/11] Project title does not match the plat. Response: Titles now match. Number: 59 03/17/2011: Repeat comment. Response: The new title matches. [2/28/11] Must be in Engineering Scale. Response: Attached drawings are in engineering scale. Created: 02/28/2011 Created: 02/28/2011 Number: Created: 03/17/2011 03/17/2011: Please remove all revision information in the title block. This is not an approved set being revised. Response: All revision information has been removed from the title block. Department: Engineering Development Review Contact: Susan Joy Topic: Landscape Plans Number: Created: 03/17/2011 03/17/2011: Please remove all extra 'line of sight' information off the plan set, only show the actual easement information on your property. Response: Line of site information has been removed. Topic: Plat Number: Created: 03/17/2011 03/17/2011: There is an easement being vacated between lots 4 and 5. What is this easement and who was it dedicated to? If someone other than the owner of this property, then the owner of the easement must sign the plat too. Response: The easement shown on the plat has apparently been vacated. New Title work provided to Intermill Land Surveying, Inc. for the preparation of this plat no longer includes reference to this easement. The easement currently shown as being vacated has been completely removed from the final plat. Please see the revised Plat. Number: Created: 03/17/2011 03/17/2011: There are several easements shown dedicated by book and page. Please label the easement with what type of easement it is. Response: These easements, the use and along with to whom they were dedicated to are shown on the final plat. Please see the revised Plat. Topic: Site Plan Number: 53 Created: 02/28/2011 03/17/2011: Ongoing comment through Final Compliance. [2/28/11] Please see scanning requirements in Appendix E6. Response: Site Plan has been modified to comply with Appendix E6. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p 303.670.5980 • f. 303.670,7162 Response: The trash enclosure is not located within the 8' UE or the sight distance easement or located in such a way that the doors swing out into public row. Department: Engineering Development Review Contact: Susan Joy Topic: General Number: 34 Created: 02/23/2011 03/17/2011: Ongoing comment through Final Compliance. [2/23/11] Please see scanning requirements in Appendix E6 and bring all plan sets up to standard. Response: Plans Sheets have been adjusted to meet the scanning requirements in Appendix E6. Number: 43 Created: 02/23/2011 03/17/2011: This comment still must be addressed. The tapering will be done within public row so there is no need for offsite easements or permission from the neighboring property owner. Notification that work will be done is all that is required. Response: This comment has been accommodated. [2/23/11] This project must construct a 6' sidewalk along the entire frontage. Any tapering to meet existing conditions must occur offsite and use radii rather than angle points. Any sidewalk width added must be done in 4' min increments. Anything less than that requires that the existing sidewalk be removed and reconstructed to the proposed width. Response: This comment has been accommodated. Number: 61 Created: 03/17/2011 03/17/2011: The front entry area has been changed since the first submittal and there now appears to be the addition of a structure of some sort in the utility easement just to the left of the west bike rack. What is that? I need more information before I can determine if this "structure" will be allowed in the UE. Also, there now is some sort of a rock wall (I'm guessing) also shown in the UE. Please provide more information so that the utilities can see if this is an issue. Please be aware that even if the retaining wall is allowed, that they will not be replaced or repaired if the utilities ever have to go into the easement to repair their lines. Acknowledged: Please see updated Utility, Site and Landscape Plans. Number: Created: 03/17/2011 03/17/2011: Please coordinate all plan sets so that they match the easements shown on the plat. Response: This has been accommodated with the utility plans where it did not negatively affect readability. Topic: Landscape Plans Number: 54 Created: 02/28/2011 03/17/2011: Repeat comment. [2/28/11] Please label and dimension all existing and proposed row and easements. Response: These have been labeled. Number: 55 Created: 02/28/2011 architecture • planning • interiors 1024 cherokee street. suite 200 • denver, colorado 80204 9 p. 303.670,5980 9 f. 303.670,7162 Department: Engineering Development Review Contact: Susan Joy Topic: Construction Drawings Number: 37 Created: 02/23/2011 [2/23/111 The index indicates that a plat was included in the plan set for reference, however, none was to be found. Either include the plat or remove it from the index. Response: The Plat has been included. Number: 39 Created: 02/23/2011 [2/23/111 Scanning issues, see redlines and comment #34. Sheet 6's sport elevations were impossible to read. Response: Plans Sheets have been adjusted to meet the scanning requirements in Appendix E6. Sheet 6's Spot Elevations have been revised and are now readable. Number: 40 Created: 02/23/2011 03/17/2011: Repeat comment. Please show all easement information on all sheets. [2/23/11] Please label and dimension all row and easements and whether they are existing or proposed. Response: This has been accommodated where it did not negatively affect readability. Number: Created: 03/17/2011 03/17/2011: Please see redlines for additional comments. Most of these can be addressed in Final Compliance with the exception of the offsite sidewalk connection to the west, the easement (especially in relation to the location of the trash enclosure) and the new additions to the front entry area. Response: Redlines have been accommodated. Topic: General Number: 31 Created: 02/23/2011 03/17/2011: Please show, label and dimension all easements on all plan sets and sheets. The site, landscape and utility plans must match the plat. Response: This has been accommodated with the utility plans where it did not negatively affect readability. [2/23/11] Please dedicate sight distance easements off each of the parking lot driveways into the alley per LCUASS figure 7-16. Response: Sight distance easements are being dedicated with the Plat. Number: 32 Created: 02/23/2011 03/17/2011: Please move all portions of the trash enclosure including the footings out of the sight distance easement. Response: All portions of the trash enclosure have been moved out of the site distance easements. [2/23/11] The trash enclosure (or any part of the structure including footings, etc) may not be located within the 8' UE or the sight distance easement or located in such a way that the doors swing out into public row. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303.670.5980 • f. 303,670,7162 1' 1 April 25, 2011 Mr. Ted Shepard City Planner Community Development and Neighborhood Services 281 North College Ave. Fort Collins, CO 80522 Tel: 970.221.6750 RE: Pura Vida Place - 518 W. Laurel St. Dear Mr. Shepard: I have attached our response to the comments from the conceptual review dated March 25, 2011. Please feel free to contact me if additional information is needed, and I will be happy to provide that to you. Sincerely, Elizabeth Johnson Odell Architect. P.C. architecture • planning • interiors 1024 cherokee street, suite 200 • denver, colorado 80204 • p. 303.670,5980 • f. 303.670.7162