HomeMy WebLinkAboutCLEARWIRE, COLLINDALE GOLF COURSE WTF - PDP - 11-10 - CORRESPONDENCE - (7)B&T Engineering, Inc.
1717 S. Boulder, Suite 300
Tulsa, OK 74119
(918) 587-4630
August 5, 2010
Subject:
Client:
Client Contact:
Carrier:
Carrier Site Name:
Carrier Site Number:
Site Location:
B&T Engineering Project ID
Dear Mr. Buckley,
Structural Analysis — Wooden Fence
Clearwire, LLC
Richard Buckley
Clearwire, LLC
Collindale Golf Course
CO-DEN1024
3874 S. Lemay Ave.
Fort Collins, CO
80931
RECEIVED
AUG 2 5 2010
B&T Engineering is pleased to submit this letter regarding the proposed plan to install telecommunications
equipment at the project location referenced above. The purpose of this letter is to address the wood fence
surrounding the equipment compound. This assessment was performed in accordance with the following
codes:
International Building Code 2006: 100 mph 3-second gust
Ft. Collins Building Code Amendments
The construction documents have been updated to reflect an 8'-0" tall wood fence with vertical posts spaced at
6'-0" o.c. max. There are (4) rows of horizontal fence members which are constructed from (2) 2x6 members —
one oriented vertically to support gravity loads and one oriented horizontally to resist wind loads. The posts are
steel pipes embed into 24" diameter concrete foundations which are 6'-0" deep.
Thank you for the opportunity to provide professional services on this project. Please contest us at (918) 587-
4630 if you have any questions or need additional information. ��
Sincerely,
B&T Engineering, Inc.
John W. Kelly
Project Engineer
NAL
Chad E. Tuttle, P.E. 0
Engineer of Record