Loading...
HomeMy WebLinkAboutCLEARWIRE, COLLINDALE GOLF COURSE WTF - PDP - 11-10 - CORRESPONDENCE - (6)2. allowing architectural embellishments consistent with architectural style, such as peaked roof sections, corner turrets, belvederes or cupolas; 3. defining and reinforcing the downtown areas the major focal point in the community; 4. allowing for maximum utilization of activity centers; 5. protecting access to sunlight; 6. providing conscious direction to the urban form of the city through careful placement of tall buildings or structures within activity centers; 7. allowing rooftop building extensions to incorporate HVAC equipment. Number: 7 Created: 6/8/2010 [6/8/10] Please provide a landscape plan showing the existing landscaping and any landscaping that is proposed Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Steve Olt City Planner Page 4 include, but are not limited to, reducing building or structure mass, changing the orientation of buildings and increasing open space setbacks. 2. Light and Shadow. Buildings or structures greater than forty (40) feet in height shall be designed so as not to have a substantial adverse impact on the distribution of natural and artificial light on adjacent public and private property. Adverse impacts include, but are not limited to, casting shadows on adjacent property sufficient to preclude the functional use of solar energy technology, creating glare such as reflecting sunlight or artificial lighting at night, contributing to the accumulation of snow and ice during the winter on adjacent property, and shading of windows or gardens for more than three.(3) months of the year. Techniques to reduce the shadow impacts of a building may include, but are not limited to, repositioning of a structure on the lot, increasing the setbacks, reducing building or structure mass or redesigning a building or structure's shape. 3. Privacy. Buildings or structures greater than forty (40) feet in height shall be designed to avoid infringing on the privacy of adjacent public and private property, particularly adjacent residential areas and public parks. Techniques to improve the level of privacy in a neighborhood may include, but not be limited to, providing landscaping, fencing and open space, and changing building or structure orientation away from adjacent residential development. 4. Neighborhood Scale. Buildings or structures greater than forty (40) feet in height shall be compatible .with the scale of the neighborhoods in which they are situated in terms of relative height, height to mass, length to mass, and building or structure scale to human scale. (b) Submittal Requirements. All development plans proposing building or structure heights in excess of forty (40) feet shall, at a minimum, include the following information: 1. a shadow analysis that indicates on the project development site plan the location of all shadows cast by the building or structure (with associated dates of the year); 2. a visual analysis that a. identifies the extent to which existing views may be blocked; b. depicts in graphic form views before and after the project, utilizing photographs of the area and neutral drawings derived from at least two (2) points from which the proposal will be commonly viewed, one (1) of which should be a vista towards the foothills; and c. indicates these points of observation on an inset map or plan of the area; and 3. a summary of the key conclusions of the shadow and visual analysis, and steps to be taken to comply with the review standards set forth above. (c) Modification of Height Limits. To provide flexibility in meeting the height limits contained in Article 4 of this Land Use Code, such height limits can be either increased or decreased by the decision maker in the development review process for the following purposes: 1. preserving the character of existing residential neighborhoods; Page 3 Contact Alan Rutz in Electric Engineering (970)224-6153 to coordinate power requirements and electric utility charges. Department: PFA Issue Contact: Carle Dann Topic: Fire Authority Number: 5 Created: 6/7/2010 PFA has no comments or concerns at this time. Department: Technical Services Issue Contact: Jeff County Topic: General Number: 2 Created: 6/4/2010 [6/4/10] There are incorrect bearings on the attached document of legal descriptions. See redlines. Topic: Land Survey Number: 3 Created: 6/4/2010 [6/4/10] There are incomplete Township & Range descriptions, on the attached document of legal descriptions and Land Survey sheet LS-1. See redlines. Number: 4 Created: 6/4/2010 [6/4/10] Please correct the Access Easement note "width" on Land Survey sheet LS-1. See redlines. Department: Stormwater-Water-Wastewater Topic: Stormwater Number: 13 [6/8/10] No comments. Department: Zoning Topic: Zoning Number: 6 [6/8/10] Building Height Review: Section 3.5.1(G) (1) Special Height Review/Modifications. Issue Contact: Wes Lamarque Created: 6/8/2010 Issue Contact: Jenny Nuckols Created: 6/8/2010 G) Building Height Review. Purpose. The purpose of this Section is to establish a special process to review buildings or structures that exceed forty (40) feet in height. Its intent is to encourage creativity and diversity of architecture and site design within a context of harmonious neighborhood planning and coherent environmental design, to protect access to sunlight, to preserve desirable views and to define and reinforce downtown and designated activity centers. All buildings or structures in excess of forty (40) feet in height shall be subject to special review pursuant to this subsection (G). (a) Review Standards. If any building or structure is proposed to be greater than forty (40) feet in height above grade, the building or structure must meet the following special review criteria: 1. Views. A building or structure shall not substantially alter the opportunity for, and quality of, desirable views from public places, streets and parks within the community. Desirable views are views by the community of the foothills, mountains and/or significant local landmarks (i.e., Long's Peak, Horsetooth Mountain). Techniques to preserve views may Page 2 Q0 6 a STAFF PROJECT REVIEW 40C Citvof Fort Collins Clearwire - Victor McAlister Date: 6/9/2010 AIS 3443 S. Galena St. #300 Denver, CO 80231 Staff has reviewed your submittal for CLEARWIRE-COLLINDALE GOLF COURSE WTF PFP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 9 Created: 6/8/2010 [6/8/10] How does the proposed tower utilize "stealth" technology as defined in Section 3.8.13(C)(15) of the Land Use Code? It is a pole with a sheath at the top to enclose the antennas. Number: 10 1Created: 6/8/2010 [6/8/10] Section 3.8.13(C)(5) of the LUC allows fencing up to 6-0" in height. The proposal is for an 8'-0" wood fence. Sheet A4 of the submittal documentation shows the equipment to be 5'-8" to T-0" in height, with the cabinet security lighting at about V-0". The proposed height of the fence would require a Modification of Standard request. Number: 11 Created: 6/8/2010 [6/8/10] Sheets Al & A2 of the plans as submitted show a landscape buffer on 3 sides along the outside of the screen fence. What type of plant material is being proposed in this buffer? Number: 12 Created: 6/8/2010 [6/8/10] Section 3.8.1(C)(9) of the LUC states that the light source for security lighting be high pressure sodium and feature down -directional, sharp cut-off luminaires so that there is no spillage of illumination off -site. What is the proposed light source? Theoretically, the proposed canister fixture should be pointed straight down. Perhaps a different type of fixture and enclosure would be better. Department: Engineering Issue Contact: Andrew Carney Topic: General Number: 8 Created: 6/8/2010 [6/8/10] The proposed Access and Utility easements will need to be dedicated by separated document prior to final plan approval. Is the existing asphalt parking lot already in an existing access easement? If not, the proposed access easement may need to extend all the way out to Lemay Ave to ensure access. Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 1 Created: 5/26/2010 [5/26/10] The transformer shown on sheet #LS-2 is a 120/240 volt, single phase. Light & Power will need a Commercial Service Information (C-1) form completed. A link to this form is available at HTTP://WWW.FCBOV.COM/UTILITIES/BUILDERS,PHP?LIST=ELECTRIC. Page 1