Loading...
HomeMy WebLinkAboutNORTH COLLEGE TACO JOHN'S - FDP - 13-10/A - CORRESPONDENCE -Number: 41 Created: 9/27/2010 (9/27/10] See redlined utility plans for other comments. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. SiT ely: Ted�Sheepard Chief Planner Page 4 Number: 39 Created: 9/24/2010 [9/24/101 There are line -over -text issues on the Utility Plans. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Landscape Plan Number: 21 Created: 7/6/2010 [9/27/10] (Repeat comment) [7/6/10] . Show water/sewer services on the landscape plan and maintain required separation distances (Trees - 10 feet from water/sewer mains and 6 feet from water/sewer service lines). Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 33 Created: 7/9/2010 [9/28/10] Repeat comment for the plat. The word "temporary" can be in the report if you want. For the plat, the word "temporary" has no meaning. The easement exists either way until the City agrees to a vacation. [7/9/10] Please remove the word "temporary" when describing the detention pond in the drainage report. The report can explain how this pond may be removed when the master plan improvements are built. Number: 44 Created: 9/28/2010 [9/28/10] The proposed duel 27-inch storm sewers need to be built for the entire width of the property. Discussions can take place on how to do this and make the interim design work with existing conditions. Number: 45 Created: 9/28/2010 [9/28/10) Please redesign the 2-year orifice located on the outlet structure to only include the release rate of .13 cfs. The grandfathered flows need to be designed to flow over the. spillway. This will provide additional protection down stream for storms less than 100-year. Number: 46 Created: 9/28/2010 [9128/10] A drainage pan is required for slopes less than 2%. The low flow channel in the pond is less than 2%. The criteria manual and the detention pond landscape standards mention if you have type A and B soils then no pan is necessary. Number: 48 Created: 9/30/2010 [9/30/10] Please label public and private storm sewers on the storm sewer plan & profile sheet. Number: 49 Created: 9/30/2010 [9/30/10] Please provide an erosion control escrow calculation in the drainage report. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterMastewater Number: 40 Created: 9/27/2010 [9/27/10] As indicated recently, the Utilities capital project group is planning to replace the existing sanitary sewer and would like to obtain additional easement and move the sewer to the east. Please coordinate a meeting with Taco John's. Page 3 between the sidewalk and curb, medians and other city property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. • The project manager shall contact the City Forester to inspect all street tree plantings at the completion of each phase of the development. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval of each phase. Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 34 Created: 9/3/2010 [9/3/10] The location shown on the utility plan for the electric transformer meets the Light & Power location and clearance requirements. The "existing Overhead Electric" shown on the south property line on utility plan, does not exist. Number: 35 Created: 9/3/2010 [9/3/10] The previous response indicated that the C-1 form will be provided with the building permit application. Please provide the completed C-1 form directly to Light & Power Engineering. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 11 Created: 7/6/2010 (9/29/10] PFA has no further comments or concerns at this time. Thank you for responding to all my conceptual comments, specifically, water supply (existing hydrant meets our requirements), Emergency Access Easement (on plat), address numerals (minimum 6 inches high, on College Avenue side of the building), abd hood/duct suppression system. Regarding the Emergency Access .Easement, please get together with me for a few minutes to decide FIRE LANE NO PARKING sign locations. Also, you will be required to submit hood/duct system plans for review and approval to PFA, 102 Remington St. Department: Technical Services Issue Contact: Jeff County Topic: Plat Number: 36 Created: 9/24/2010 [9/24/10] The Subdivision Plat boundary & legal close. Topic: Site Plan Number: 37 Created: 9/24/2010 [9/24/10] There are line over text issues on the Site Plan. Topic: Utility Plan Number: 38 Created: 9/24/2010 [9/24/10] Please correct the benchmark descriptions & Basis of Bearings statements on the Utility Plans. Page 2 *. STAFF PROJECT REVIEW Citvof Fort Collins Jim Nichols Date: 10/1/2010 Taco John's International, Inc. 808 W. 20th St. Cheyenne, WY 82001 Staff has reviewed your submittal for NORTH COLLEGE TACO JOHN'S PDP - TYPE II AND FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Andrew Carney Topic: General Number: 7 Created: 7/2/2010 [9/27/10] Comment carried forward as a reminder. [7/2/10] This project is responsible for the design and construction of the ultimate improvements along its frontage on North College. However, since it is not appropriate to make the improvements at this time, this project will be required to escrow the funds required for the design and construction of the frontage improvements. Topic: Utility Plan Number: 42 Created: 9/28/2010 [9/28/10] Where exactly is the proposed C&G with this project proposed to end at the drive entrance onto College and the future C&G begin? It appears there is a line delineating future & proposed on the utility but it is unclear. Please clearly label what will be constructed with this project and what will be left for the future. Number: 43 Created: 9/28/2010 [9/28/10) Engineering would like to see some sort of grate or guard over the proposed headwall structure along College to protect vehicles in the event of a car driving off the road in that location. The CDOT roadside structures manual has several options. Department: Forestry Issue Contact: Tim Buchanan Topic: Landscape Plan Number: 47 Created: 9/29/2010 [9/29/10] Previous Landscape Plan showed street trees between the sidewalk and curb. The current landscape plan sheet L1 does not show street trees. There needs to be 5 street trees located across the frontage. Honeylocust or Catalpa would be good choices. Add Planting notes: • The soil in all landscape areas, including parkways and medians, shall be thoroughly loosened to a depth of not less than eight (8) inches and soil amendment shall be thoroughly incorporated into the soil of all landscape areas to a depth of at least six (6) inches by tilling, discing or other suitable method, at a rate of at least three (3) cubic yards of soil amendment per one thousand (1,000) square feet of landscape area. • A permit must be obtained from the City forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones Page I