HomeMy WebLinkAboutPRESIDIO APARTMENTS - FDP - 25-09/A - CORRESPONDENCE -Department: Zoning Issue Contact: Jenny Nuckols Topic: zoning Number: 5 Created: 8/6/2009 [10/26/09] [8/6/09] Entry Monument. A separate review and permit is required for signage. The entry monument sign shown on these drawings does not receive approval at the time of this developments approval. Number: 6 Created: 8/6/2009 (10/26/09] [8/6/09] Provide note on landscape plan regarding installation of landscaping prior to issuance of Certificate of Occupancy. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Tdhepard Chief Planner Page 5 Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 59 Created: 11 /17/2009 [11/17/09] For all riprap, please specify planted riprap per the detail on sheet EC2 to promote vegetation growth. Number: 60 Created: 11 /17/2009 [11/17/09] The purpose of the underdrain is not known without an outfall. An outfall looks to be difficult, but it would definitely mitigate against standing water concerns. Number: 61 Created: 11 /17/2009 [11/17/09] Please add a pond depth gauge for the detention pond and provide a detail. Number: 62 Created: 11 /17/2009 [11/17/09] Please add pond and basin summary tables to the drainage plan. Number: 63 Created: 11 /17/2009 (11/17/09] Please revise elevation A on the water quality outlet structure detail per redlines. This will match the elevation on the detailed grading plan. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterMastewater Number: 47 Created: 11 /12/2009 [11/12/09] Add steel casing at locations where water mains are crossing under storm drains 24-inch or larger. Number: 48 Created: 11 /12/2009 [11/12/09] In Drive P, switch water main and storm drain locations to avoid water main lowerings at horizontal bends and to eliminate one lowering. Schedule meeting to discuss the details of this change. Number: 49 Created: 11 /12/2009 [11/12/09] Show any gas and UGE lines within site. Number: 50 Created: 11 /12/2009 111/12/09] On Sheet SS1, show utilities in plan view. Number: 51 Created: 11/12/2009 [11/12/09] Provide a detail of the lowering of the existing water main east of Cinquefoil and add steel casing. Number: 52 Created: 11 /12/2009 [11/12/09] Provide notes for the re -location of the water main in Precision regarding disinfection of the main from Lady Moon to Cinquefoil. Number: 58 Created: 11 /12/2009 [11/12/09] See redlined plans for other comments. Page 4 Number: 46 Created: 11 /10/2009 [11/10/09] On sheet R1 of the Precision Drive Plans where Precision Drive matches the existing design from TST, the station referenced does not appear to match the TST stationing. Also, the elevations do not appear to match. Please revise so that the two designs match at the tie in point. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 57 Created: 11 /12/2009 PFA and City GIS will continue working with the USPS to devise an addressing method that is logical, consistent with current addressing practices and acceptable first to emergency response. Department: Technical Services Issue Contact: Jeff County Topic: General Number: 56 Created: 11 /12/2009 [11/12/09] All legal descriptions received via email on 10/21/09 from Nick Haws for ROW & easements along Precision Drive looked good. Topic: Landscape Number: 20 Created: 8/12/2009 [11/12/09] There are minor line -over -text issues on sheet LP2 of the landscape plans. (8/12/09] The landscape plans have line over text(scanning) issues. See redlines. Topic: Lighting Plan Number: 24 Created: 8/13/2009 [11/12/09] The photometric plan was included in the review set provided to Technical Services, so we reviewed it. We review all plans that are routed to us for review. The City Engineering Department scans & archives all documents that are filed with a development. *The 8/17/09 response to our 8/13/09 comment: "The Photometric Plan is not a part of the Final Plan submittal, and it is not believed to be a document that is typically scanned and archived." [8/13/09] The photometric plan has text over text issues. See redlines. Topic: Plat Number: 53 Created: 11 /12/2009 [11/12/09] Please add a note to sheet 2 of the plat stating, "See sheet 3 of 3 for new easements dedicated by this plat.". Number: 54 Created: 11 /12/2009 [11/12/09] Please see Sheri Langenberger's comments regarding the area of right of way at Precision Drive & Lady Moon Drive. Number: 55 Created: 11 /12/2009 [11/12/09] The boundary and legal close. Page 3 When dedicating the row for Precision Drive, radii at the intersection of Precision and Lady Moon should be provided as they have been for the other intersections. The legal descriptions have not been checked yet as they will be changing. They will be checked once they are resubmitted and the processing fees are paid. The processing fees are $250 per easement or row dedication. Department: Engineering Issue Contact: Andrew Carney Topic: General Number: 38 Created: 11/10/2009 [11/10/09] On sheet U1 there are two utility connections in Cinquefoil, it appears that the northern connections is outside of the current constructed pavement. It should not be shown as a patch if the connection will take place before the northern portion of Cinquefoil is built. It seems odd to pave the new section and then cut into it. Number: 39 Created: 11 /10/2009 [11/10/09] On sheet SS1 the Sanitary Sewer line A is not shown on the plan on the top of the page. Number: 40 Created: 11 /10/2009 [11/10/09] On sheet G1 of the Precision Drive Plans the background infrastructure isn't needed. Number: 41 Created: 11 /10/2009 [11/10/09] On sheet R1 of the Precision Drive Plans a few of the existing and proposed lineweights are the same. Please revise so it is obvious what is existing/proposed. Number: 42 Created: 11 /10/2009 [11/10/09]. On sheet R1 of the Precision Drive Plans, please show the flowline and centerline profiles through the intersections. Number: 43 Created: 11 /10/2009 [11/10/09] On sheet R1 of the Precision Drive Plans, please use North and South on the flowline profiles, not left and right. Number: 44 Created: 11 /10/2009 [11/10/09] On sheet R1 of the Precision Drive Plans, please show the transition lengths off of both Cinquefoil and Lady Moon. It may be useful to show an enlargement of the intersections with the spot elevations and transitions lengths (figure 7-27) called out as well as where the end of construction will be for the North and East legs of the Cinquefoil/Precision intersection. Since the design is tying into the existing Lady Moon Street stub it is ok to simply show the transition length off of lady moon as well as the centerline spot elevation as detailed in detail 7-27. However on the Precision/Cinquefoil intersection please show where exactly the end of construction with this project will be. Number: 45 Created: 11 /10/2009 [11/10/09] On sheet R1 of the Precision Drive Plans, please reference the Brookfield Cinquefoil Plans on the profiles where the design will match the Brookfield Design. Page 2 r City of Fod Collins KEPHART 2555 WALNUT ST DENVER, CO 80205 STAFF PROJECT REVIEW Date: 11 /17/2009 Staff has reviewed your submittal for PRESIDIO APARTMENTS PDP - TYPE II AND FINAL PLANS, and we offer the following comments: &KII1*-3 Department: Engineering Issue Contact: Sheri Langenberger Topic: General Number: 37 Created: 11 /5/2009 [11/5/09] In reviewing the legal descriptions for the off -site dedications I have the following comments: A dedication of row at the driveway was shown. This should not be needed as any ramps should be able to be accommodated within the 8 foot parkway that exists on this street. Only one ramp is needed for crossing the street as this is considered a T intersection even though the driveway aligns with the street. Not having this dedication would save the processing and filing fee costs to review, process, and accept this dedication. The dedication of Row along the North boundary is showing a bump in for the driveway to accommodate ramps for a mid block crossing. It is not typical to have mid -block ramps at a driveway and on both sides of the driveway. The location for a mid -block pedestrian crossing will need to be reviewed and approved by traffic operations. As we discussed it may make more sense to look at this and discuss the mid -block crossing when the block to the north is brought in for review and the desired pedestrian spine location is defined and the ramps added at that time. Because of this, the preference is that the driveway be built in accordance with the standard details where the sidewalk goes straight across the driveway and does not bump into the site for the crossing. As shown on the plat there is a portion of property that was at one time dedicated as row to a private party (not to the city). The area of the dedication which is within the platted boundaries is being shown to be vacated with the plat. The portion of this row that is within the row for Precision drive that is being dedicated to the city by separate document also needs to be vacated prior to the dedication. We have thought of a couple of options for how this can be done: Option 1. Extend the boundaries of the plat to include this area and thus the dedication would also be vacated by the note that is on the plat. The area would then be dedicated as row on the plat. Option 2. Some sort of special language could be included within the deed language to identify that the owner is vacating/giving up row rights as dedicated to them and then dedicating the land to the city. This would seem to work since you have indicated that the row and the land are owned by the same party. Any proposed language will need to be reviewed by the City Attorneys office. We are open to other options as well if you have other ideas. Page 1