HomeMy WebLinkAboutPENNY FLATS - MAJOR AMENDMENT - 19-09 - REPORTS - RECOMMENDATION/REPORTAdministrative Public Hearing Sign -in
Project: P5NN'1 )C7Lff7--S m.4JT41, Ai4,1c-A),oAs6-^j7-
Meeting Location: aD /U . C, 6E- pq
Date: p-v O u .r 7- y o2 G 0 9
PLEASE PRINT CLEARLY
�.� r �� ■
L�111� . I �,:. ���G.. � ` - � ■iifrlll(a1► �1 ..
AL
Lie, S (n 5�, i ( (V �3 Z k, S (-J
O Ds 442� �3S �� ✓►t ®CVr�lG�2�,Gvw.
l�-
o�u 1 ®e,>6
All sides of each building have high quality materials consistent with the
front fagade. Primary building entrances are recessed into the building
mass or feature a foyer and are covered with either an awning or portico.
Awning length corresponds to building bays for a human scaled effect. All
buildings have been designed with appropriate base and top treatments
including stone and masonry cornices and stone and tile bases.
G. Transportation Level of Service Requirements
The Major Amendment adds 23 dwelling units and decreases commercial
floor area by 3,846 square feet. These changes do not affect the levels of
service along the surrounding public streets and intersections.
4. Findings of Fact / Conclusion:
A. Mixed -use dwellings are permitted in the Downtown District, Civic
Center Subdistrict, subject to an Administrative Hearing.
B. The project results in an increase of 23 dwelling units which
exceeds one -percent of the total thus triggering a Major
Amendment.
C. Buildings Three and Four increase in height from four stories to six
stories which is permitted in Civic Center Subdistrict.
D. The Major Amendment continues to comply with the General
Development Standards as well as the applicable District
Standards.
RECOMMENDATION
Staff recommends approval of Penny Flats Major Amendment, #19-09.
7
The Major Amendment allows Penny Flats to remain complementary with
the neighborhood and historic context of the surrounding area. The
project continues to transitions appropriately from the existing
neighborhood and Civic Center, both in terms of height and massing.
For example, there are no changes along Howes Street where the
townhouses remain two stories in height with a pop-up loft that is set back
from the fagade. The buildings are further broken down into fifteen foot
bays resulting in a fine grain that blends well with the existing homes
across the street.
On the Maple and Mason facades, the building module is approximately
24 feet which is appropriate for the commercial fronts and the more urban
context. The continued use of brick, stone, commercial display windows
and detailing at the ground floor promote compatibility with the
surrounding area.
D. Section 3.5.3(G) — Height — Shadow Analysis
This standard requires that buildings over 40 feet do not cause a
substantial adverse impact on the distribution of natural and artificial light
on adjacent public and private property.
A shadow analysis indicates that with the increase in two stories,
Buildings Three and Four cast shadows that are slightly enlarged than the
approved plan. For example, there is now a small corner of shadow on
the southeast corner of the Trolley Barn under the conditions of December
21st. This impact is not considered substantially adverse.
E. Section 3.5.3 — Relationship of Buildings to Streets, Walkways and
Parking
This standard requires pedestrian orientation to a walkway or street.
Building Three continues to orient to the civic center spine. Building Four
continues to orient to Mason Street.
F. Section 3.5.3 — Mixed -Use Buildings — Character and Image,
Facades, Entrances, Base and Top Treatments
This standard prescribes architectural standards.
The Major Amendment continues to provide facades that exceed the
minimum wall articulations. Walls have clearly defined bays, multiple
changes in plane, materials and texture, arcades, awnings and porticos.
2
H. Section 4.16(E)(c) — Plazas and Section 4.16(F) — Special
Provisions — Civic Center Subdistrict
This standard requires the project to provide for the civic center spine.
The Major Amendment continues the civic center spine connecting Mason
Street North to the north to the City office building to the south. Ultimately,
the pedestrian spine meanders from about 20 feet wide at its narrowest, to
45 feet at its widest. Residential entries line the spine promoting activity.
Special paving and scoring is proposed along with landscaping and
pedestrian amenities such as benches, bike racks and seating walls to
ensure that this space will be used and enjoyed.
3. Compliance with Applicable General Development Standards:
A. Section 3.2.2(K) Parking
Multi -family and mixed -use dwellings within the Transit -Oriented
Development (TOD) Overlay Zone have no minimum parking
requirements. The Major Amendment, however, will provide six additional
parking spaces for a total of 323 to serve 170 dwelling units and 25,400
square feet of commercial floor area.
B. Section 3.4.7 — Historic and Cultural Resources
Buildings Three and Four are southeast of the historic Trolley Barn, a
significant historic asset designated in 1992 as a Local Landmark and
owned by the City of Fort Collins. These standards require that the
proposed development protect and enhance the value of the adjacent
historic resource.
The Major Amendment preserves the integrity of the Trolley Barn primarily
by use of brick and stone exterior materials. Though more modern, the
architectural design is sensitive to the Trolley Barn by stepping back
building massing and mitigating the mass with articulation fenestration.
Buildings One, Two and Seven adjoin the Trolley Barn and do not change
with the Major Amendment. The Landscape Plan continues to show
additional trees at the northwest edge of the pedestrian spine to provide
some buffering and to enhance the area around the Trolley Barn.
C. Section 3.5.1— Architectural Character, Building Size, Mass and
Scale
This standard requires that the Major Amendment remain compatible with
the surrounding area, particularly the residential area to the west.
5
Building Three is all residential and features two set backs above the
base. Building Four is mixed -use with commercial space along Mason
Street and residential units above and the top floor is set back at a 45-
degree angle from the floor plane of the sixth story.
D. Section 4.16(D)(5)(a) — Building Character and Facades — Blank
Walls
This standard requires that no blank walls that face a public street, public
plaza or walkway shall exceed 50 feet in length.
For both Buildings Three and Four, there are no blank walls that exceed
50 feet in length.
E. Section 4.16(D)(5)(b) — Building Character and Facades — Outdoor
Activity
This standard requires that buildings promote outdoor activity with
balconies, arcades, terraces, decks and courtyards to the extent
reasonably feasible.
The Major Amendment continues the pedestrian spine that bisects the
entire block and continues to provide ample balconies for the dwelling
units.
F. Section 4.16(D)(5)(e) — Building Character and Facades — Exterior
Fagade Materials
This standard requires that all street -facing facades shall be constructed
of high quality materials for the full height of the building.
Both Buildings Three and Four maintain a combination of brick, stucco,
split face concrete block and metal siding for the full height of each
structure.
G. Section 4.16(E)(a) — Parking Lots
This standard requires that parking lots not dominate street frontages.
Parking lots have been designed sensitively to avoid interrupting the
pedestrian focus of the project. Parking lots are primarily underground.
Some parking is provided behind the buildings off of the internal drive
aisles. Two auto entrances have been located on Maple Street and are
recessed to minimize appearance and maximize safety.
4
This project is a public -private partnership between the City of Fort Collins and
Coburn Development, Inc. The process began in July, 2004 when City Council
passed Resolution #2004-081which directed the City Manager to initiate a
process for disposition and appropriate development of Block 33. The City
issued Request For Proposal (RFP) #P955 in September, 2004 to seek a
qualified development team to purchase the property and develop it according to
the Civic Center Master Plan, adopted by the City Council in July 1996. The City
interviewed 8 finalist teams and chose Coburn Development, Inc.
2. Compliance with Applicable Downtown District - Civic Center
Subdistrict Standards:
A. Section 4.16(D)(2) — Building Height
This standard establishes the maximum allowable building heights in the
Civic Center on a block -by -block basis.
Buildings Three and Four will increase from four stories (56 feet) to six
stories (84 feet). The maximum allowable height on Block 33 is six stories
(85 feet). The Major Amendment, therefore, complies with this standard.
B. Section 4.16(D) (4) (b) 1. — Building Mass Reduction for Taller
Buildings - Base
This standard requires that buildings over three stories shall have base
that is differentiated from the remainder of the building.
Both Buildings will feature pedestrian entrances and windows along the
pedestrian spine (Building Three) and Mason Street (Building Four). The
base portion of Building Three is two stories in height and is clearly
defined by windows, second floor balconies and capped by a prominent
horizontal band. The base of Building Four is one story with non-
residential store -fronts on the ground floor and residential units above.
For both buildings, the use of different exterior materials further
distinguishes the base from the remainder of the building.
C. Section 4.16(D)(4)(b)2. — Building Mass Reduction for Taller
Buildings — Upper Floor Setbacks
This standard requires that upper portions of taller buildings shall be
further set back above the base in such a manner as to contribute to a
significant aspect of the building design.
3
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
Mixed -use dwellings are permitted in the Downtown District, Civic Center
Subdistrict subject to an Administrative Hearing. The Major Amendment is
triggered by an increase of greater than one -percent in the number of dwelling
units. The Major Amendment continues to comply with the applicable
Administrative and General Development standards and the standards of the
Downtown, Civic Center district.
COMMENTS
1. Background:
The surrounding zoning and land used are as follows:
N: D—Downtown District - Civic Center Subdistrict with LMN—Low
Density Mixed -Use Neighborhood (existing residential and a mixed -use
project);
NE: POL—Public Open Land — vacant land;
E: D—Downtown District - Civic Center Subdistrict — vacant land and
abandoned tire shop and drive -through restaurant;
SE: D—Downtown District - Civic Center Subdistrict — existing Downtown
Transit Terminal and existing office, retail and mixed -use;
S: D—Downtown District - Civic Center Subdistrict — Existing office and
industrial (City office building and the former Haiston Oil Company),
with existing Larimer County government offices;
SW: D—Downtown District — Civic Center Subdistrict — Existing park and
municipal government offices;
W: D—Downtown District — Civic Center Subdistrict — Existing single family
residential and existing office with NCB —Neighborhood Conservation
Buffer District;
NW: NCB —Neighborhood Conservation Buffer District with NCM—
Neighborhood Conservation Medium Density beyond.
All the property within Block 33 is currently City -owned. The historically
significant Trolley Barn at the northwest corner of the block will be retained in
City ownership. The rest of the block may ultimately be sold to Penny Flats, LLC
to build a mostly residential mixed -use project. There are a few existing
buildings on the southwest quadrant of the block that will be demolished at the
time of redevelopment.
E
Fart Collins
EM NO -+7
MEETING DATE &t/6&$r V .2co9
STAFF 2E A Leo
HEARING OFFICER
PROJECT: Penny Flats Major Amendment, #19-09
APPLICANT: Dan Rotner
Coburn Development Inc.
1811 Pearl Street
Boulder, CO 80302
OWNER: City of Fort Collins
c/o Ken Mannon, Operations Services Director
117 N. Mason St.
Fort Collins, CO 80524
LEGALINTERESTS:
Penny Flats, LLC
1811 Pearl Street
Boulder, CO 80302
PROJECT DESCRIPTION:
Penny Flats is an approved project consisting of eight buildings on Block 33
which is bounded by Maple Street, Howes Street, Cherry Street and Mason
Street. One building has been constructed and is partially occupied. The current
request is for a Major Amendment to future Buildings Three and Four.
As proposed, the amendment consists of increasing the total number of dwelling
units from 147 to 170 for a gain of 23 units. In addition, the total floor area of the
project would increase from 200,838 square feet to 222,831 square feet for a
gain of 21,993 square feet. The original approved floor area of commercial uses
was 29,246 square feet will be decreased to 25,400 square feet for a loss of
3,846 square feet. Also, the original number of parking spaces would increase
from 317 to 323 for a gain of six spaces.
Finally, the height of Buildings Three and Four will increase from four stories (54
feet) to six stories for gain of two stories (84 feet). The site is 2.6 acres and
zoned D, Downtown District, Civic Center Subdistrict.
Current Planning 281 N College Ave - PO Box 580 - Fort Collins, CO 80522-0580
fcgov.com/currentplanning 970.221.6750