HomeMy WebLinkAboutBELLA VIRA - FDP - 36-05A/B - SUBMITTAL DOCUMENTS - ROUND 2 -Sincerely, Jim Sell Design, Inc. Matthew J. Blakely, ASLA Project Manager cc: John Minatta File Page 17 of 17 In an e-mail correspondence with Roger this issue was clarified. Steel casings will only be needed for water and sanitary lines crossing under storm pipes that are 24" in diameter and larger. In an attempt to maximize cover between the top of pipes and travel surface, the largest culvert with this issue is 18 ". Therefore steel casings have not been included in the design. Number: 169 Created: 2/16/2007 [2/16/07] The multi -family bldg #4 with only 2 units doesn't need a 1.5" water service. Multi family bldg #4 water service has been changed to 1 inch. Number: 170 Created: 2/16/2007 [2/16/07] Is a 3/4" irrigation service adequate for the multi -family area? Provide sizing calc's. This service has been upsized to 1 ". Number: 171 Created: 2/16/2007 [2/16/07] Width determination of the insulation over the 16" water main doesn't seem reasonable. Review and call me to discuss. Reviewed with Roger Buffington and Susan Joy at a meeting. Discussed changes have been incorporated. Number: 172 Created: 2/16/2007 [2/16/07] Are there water main lowerings on the project? If so, label on the overall utility plan, provide a detail with elevation information and add detail 4-B. There aren't any water main lowerings designed with Bella Vira. The detail has been removed. There are two existing watermains entering the site at Sunflower and Banyan that may conflict with proposed storm pipe crossings. These will need to be pothole previous to construction and a lowering may be deemed necessary at that time. Number: 173 Created: 2/16/2007 [2/16/07] Add the details for the 1.5" meter pit installations. Detail has been added Number: 174 Created: 2/16/2007 [2/16/07] Include the insulation spec on the plans (Dow Styrofoam Highload 60). This was discussed during a meeting with Roger Buffington and Susan Joy — it was determined that the insulation would be identified on the plans as Highload 60 and that further specs/documents would not need to be added to the set. Number: 175 Created: 2/16/2007 [2/16/07] Curb stops must be within the utility. easements (but NOT in sidewalks). Adjust curb stops in multi -family area. Curb stops adjusted to be in compliance with request If you have any questions or concerns, please don't hesitate to contact me at (970) 484-1921. Page 16 of 17 Number: 187 Created: 2/16/2007 [2/16/07] Please show the HGL on the storm profiles. See Storm Plan and Profile sheets. Number: 188 Created: 2/16/2007 [2/16/07] Please provide pond emergency spillway cross-section and detail. Table A.1 S of the Drainage report details these emergency spillways and the Drainage and Grading plans have spot elevations, slopes and locations. Cross -sections have been left out of this submittal and will be added previous to mylar if deemed necessary. Number: 189 Created: 2/16/2007 [2/16/07] Please show detention pond depth markers in all detention ponds greater than 4 feet deep and show City's detail on the plans. Please see Drainage and Erosion Control Plan for marker locations and Drainage Detail Sheets for City's detail. Number: 190 Created: 2/16/2007 [2/16/07] Please add a sub -basin summary table and a detention pond summary table to the drainage plan. Sub -basin and detention pond summary tables have been added to the Drainage and Erosion Control Plan. Number: 191 Created: 2/16/2007 [2/16/07] Please use the City's standard water quality outlet structure detail instead of the custom outlet structure details. Custom outlet structure has been replaced with City standard. Number: 192 Created: 2/16/2007 [2/16/07] Please provide erosion surety and effectiveness calculations in the drainage report. Both of these items have been added to the drainage report. Number: 193 Created: 2/16/2007 [2/16/07] Please see additional redlined comments on the plan set and in the drainage report. Additional redlines have been addressed. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 168 Created: 2/16/2007 [2/16/07] Add steel casings on the water mains and sanitary sewers that cross below the dual storm culverts. Calculate length of casing by using a 1:1 slope from the outside of the storm culverts down to the elevation of the water/sewer mains. Specify the length, diameter and thickness of each casing. Page 15 of 17 Sidewalk on north side of West Elizabeth has been eliminated as agreed upon during review session on February 14. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 181 Created: 2/16/2007 [2/16/07] Please provide detailed grading for the single family lots. This includes spot elevations at lot comers, building envelopes with F.F and F.G. elevations, etc. Detailed grading with Top of Foundation (T.F) elevations for single family lots have been included — see Rough and Final Grading Plans. Number: 182 Created: 2/16/2007 [2/16/07] Please provide detailed grading for the multi -family area with F.F. elevations for the multifamily units. Detailed grading with minimum garage floor (G.FE) elevations for the multi family has been included. Please see the Final Grading Plan. Minimum garage floor elevations were deemed to be more useful and accurate than F.F. elevations. The Multi family units may be fine tuned between now and construction and there may be a minimum number of steps involved between the garage floor and finished floor. The finished floor elevations will be no lower than the minimum garage floor elevations provided, and will almost certainly be higher by an amount unknown at this time. Number: 183 Created: 2/16/2007 [2/16/07] Please show all inlet and storm sewers on the landscape plan and provide 10 feet of separation between all storm sewers and trees. Inlets and storm sewers have been shown with the proper separation. Number: 184 Created: 2/16/2007 [2/16/07] The modified curb cuts and sidewalk chases on Banyan Drive at the southern edge of the development need to be concrete chases. Please use the City's detail D-12. Concrete chases are used when water is being taken off the street. Metal sidewalk chases are used when water is flowing onto the street. Modified curb cut detail has been removed and replaced with standard details D12 (vertical curb) and D13 (drive -over curb) from the "City of Fort Collins Stormwater Utilit -Storm Drainage Design Criteria and Construction Standards " manual. Number: 185 Created: 2/16/2007 [2/16/07] Please remove the contours from within the multi -family buildings, as well as the building envelopes for the single family lots once they are put on the plans. Please. see the Final Grading Plan for the single family and multi family areas. Number: 186 Created: 2/16/2007 [2/16/071 Sheet 28, Storm Plan and Profiles, was missing from the plan set. This was an oversight —please see missing storm profiles included with current submittal. Page 14 of 17 [12/30/05] Wildlife Conflict - Section 3.4.1 (17)(3) will need to be met. One option for a protection mechanism may be to provide future residences with a letter or brochure detailing potential conflicts. • Harmony Ridge 2nd filing Wildlife letter is a good example to refer to. A "Potential Conflicts: Residents and Wildlife " letter for Bella Vira has been prepared and was reviewed and approved by Doug Moore with the original PDP. This letter will be distributed to future residences of Bella Vira. Department: PFA Topic: fire Number: 67 Issue Contact: Carle Dann Created: 2/6/2006 [2/14/07] The Emergency Access Easement is required to be designated on the plat. Per previous discussions, parking on Bella Vita will be allowed only in the bump -out parking areas. Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route (from a public street) around the exterior of the building or facility. This fire lane shall be the required minimum width of 20 feet throughout the length of the fire lane; designated an emergency access easement on the plat; visible by painting and signage; and maintained unobstructed at all times. The HOA is responsible to maintain the approved fire lane signs and red -painted curbs. A fire lane plan shall be submitted for approval prior to installation. If a fire lane is not provided, all buildings out of access (exceeding the 150- foot requirement) shall be equipped with an approved automatic fire -sprinkler system. 97UFC 901.2.2.1; 901.3; 901.4.2; 902.2.1 [4/19/06) This issue is revolved. However, I wanted to note that this private drive is now named Bella Vita Drive. Also, we need to ensure it is designated EAE on the plat. [2/6/06] The private drive shown as Vira Drive shall be a fire lane and shown on the plat as an emergency access easement. Vira Drive is required to be an unobstructed 20-foot-wide fire lane, signed "FIRE LANE - NO PARKING" and painted with red curbs, and it shall meet the remainder of the design criteria for fire lanes stipulated in section 3.6.6 of the FCLUC. The emergency access easement has been labeled on the plat. Please seethe Onsite Signing and Striping plan for emergency signage and striping. Number: 92 Created: 4/19/2006 [2/14/071 [4/19/061 We require a Knox Box be mounted to the appropriate structure(s) so we can access the automatic -sprinkler riser room(s) supplying the multi -family dwellings. Noted. Department: Transportation Planning Issue Contact: David Averill Topic: Site plan Number: 132 Created: 2/13/2007 [2/13/07] No further comments but we do need to discuss the maintenance responsibility for that portion of sidewalk (north side of W.Elizabeth) which lies adjacent to CSU property. Page 13 of 17 Meters located at end of building opposite of gas per routing plan agreed upon with Doug Martine. Building 4 is the lone exception where electric and gas services are located on north side of building as far apart as possible. Number: 112 Created: 1/25/2007 [1/25/07] The developer will need to coordinate utility sleeves across the box culvert with Light & Power Engineering before culvert is constructed. This note is for informational reasons only and NOT a pre -requisite to plan approval. Noted. Department: Natural Resources Issue Contact: Doug Moore Topic: General Number: 40 Created: 12/30/2005 [2/9/07] [12/30/05] Limits of Development, LUC 3.4.1 (N) - Limits of development and details explaining installation of barrier fencing will need to be show on plans drawings related to the construction near the following natural habitats and features: Wildlife movement corridor Existing cottonwood and peach -leaf willow trees Limits of Development added to Site, Landscape and Utility Plan set. Number: 41 [2/9/07] Created: 12/30/2005 [12/30/05] The portion of this project that lies within the R-F zone district will be required to meet section 3.4.1 (1) Design and Aesthetics of the Fort Collins Land Use Code. This may require the development of general architecture design standards for lots within the zone district to ensure that the standard will be met as individual lots are sold and developed. ** Harmony Ridge 2nd filing General Architect Standards are a good example to refer to. Updated Architectural Standards are included on sheet 1 of the Landscape Plan as agreed upon with Dana Leavitt. Number: 42 Created: 12/30/2005 [2/9/07] [12/30/05] Prairie Dogs - Standard language will be added to the development agreement for this project to ensure that construction activities including grading will not be allowed to occur on the development site if prairie dogs relocate to or inhabitant the site either prior to or during construction. At any time construction activities occur with prairies on site construction activities will be stopped until the situation is corrected. If relocation of prairie dogs on to the construction site becomes an issue the Natural Resources Department may require the developer to install a temporary barrier fencing to try to limit the animals ability to move on to the site. 3.4.1(F), 3.4.1(N)(6) Acknowledged. Number: 43 [2/9/07] Created: 12/30/2005 Page 12 of 17 Department: Engineering Issue Contact: Susan Joy Topic: Utility Plan - Signing and Striping Number: 156 Created: 2/15/2007 [2/15/07] Please route Traffic Engineering with the next round so that they can review this sheet. An extra copy of the submittal has been added for Traffic. Topic: Utility Plan - Typical Street Sections Number: 155 Created: 2/15/2007 [2/15/07] Correct the local residential section, see redlines. Section has been corrected. Topic: Utility Plan - Underdrain Number: 158 Created: 2/15/2007 [2/15/07] Please provide an updated underdrain report The report completed by Anderson Consulting Engineers in September of 2006 has not been revised after the September completion elate. The Water/Wastewater, Storrnwater and Engineering departments all received copies of the report and no one has requested ally specific modifications or cited any technical problems With the report. . Number: 159 Created: 2/15/2007 [2/15/07] Minimum slope requirement is not being met. The minimum slope note of 0.4% was for the sanitary line. The slope in question is within the parameters set by the underdrain report. Topic: Utility Plan - Utility Number: 157 Created: 2/15/2007 [2/15/07] Please note that driveways may not be placed over the waterline to any lot. Please note this on the site plan as well. This has been noted on the Utility Plan and Site Plan. Department: Light & Power Issue Contact: Doug Martine Topic: Utility Plan Number: 3 Created: 12/22/2005 [2/16/07] Janet McTague of Light & Power asked where the meters are to be located on the 25 multi -family units at the east end of the development, near Overland Trail. [1/25/07] Meters located at end of building opposite ofgas per routing plan agreed upon with Doug Martine. Building 4 is the lone exception where electric and gas services are located on north side of building as far apart as possible. [12/22/05] Locations of electric and gas meters on multi -family buildings will need to be coordinated with Light & Power and Excel prior to construction. Electric and gas meters should be on opposite ends of each building. Page 11 of 17 Topic: Utility Plan - Plan & Profiles Number: 149 Created: 2/15/2007 [2/15/07] Dimension all crosspans and show them in the profiles. Crosspans have been called out and dimensioned on the plan and profile sheets. Number: 151 Created: 2/15/2007 [2/15/07] Minimum cover requirements are not being met. Please refer to 12.2.2 After meeting with City staff on this issue is was agreed that, with a variance, 15 "-18" of cover over the pipes to the bottom of subgrade would be acceptable. Minimum cover over the storm pipes for this project is 18"to bottom of subgrade. Please seethe variance request included with this submittal titled "Minimum Utility Cover ". Number: 152 Created: 2/15/2007 [2/15/07] Please provide a transition detail for the VC to rollover curb. The proposed length of transition, spot elevations and beginning and end, location and stationing has been added to the West Elizabeth Plan and Profile sheet. Number: 153 Created: 2/15/2007 [2/15/07] Please use a VC, sheet 17. A vertical curve has been used in place of the grade breaks — see Overland Trail plan and profile. Department: Engineering Issue Contact: Dan DeLaughter Topic: Utility Plan - Plan & Profiles Number: 21 Created: 12/29/2005 [2/13/07] Repeat comment. Also, now missing centerline profiles. Please stack all of the profiles vertically so that they line up. Please provide separate intersection spot details (can do all on one sheet if you like). The spots shown on the plan view are too small to read and will not scan. Please refer to E6 for minimum font size requirements. Minimum cover requirements are not being met (see 12.2.2 of LCUASS). Missing info - crosspans aren't dimensioned, centerline profile needs to continue to centerline of intersecting street, need to show all existing utilities that may be crossing the street in the plan and profiles (district, etc), missing slope %, taper doesn't meet standard on Overland. [4/6/06] [12/29/05] Flowline profiles will be needed in addition to centerline profiles for final compliance. Also at final, we'll want to see station and approximate locations of all utility crossings, and driveways. These comments have all been addressed Number: 78 Created: 4/6/2006 [2/13/07) [4/6/06] Please extend street profiles to the centerline of intersecting streets. Profiles have been extended. Page 10 of 17 LCUASS has been reviewed and information has been added to the cross sections. Topic: Utility Plan - Details Number: 165 Created: 2/15/2007 [2/15/07] See redlines. Remove 7-19, 11-08, 7-917 and the ped ramp details. Add 701, 708, 1413, 1601, 1602 and the new ped ramp detail. Email me at sjoy@fcgov.com and 1711 send you the cad file. Add "onsite" to the concrete details. Sheet 38 - see redlines. Changes have been made — see detail sheets. Topic: Utility Plan - General Notes Number: 148 Created: 2/15/2007 [2/15/07] Remove D - this is redundant. Section D has been removed. Topic: Utility Plan - Grading Number: 134 Created: 2/13/2007 [2/13/071 Proposed contours do not tie into existing contours in all locations. Acknowledged, corrected -see grading plan. Number: 135 Created: 2/13/2007 [2/13/07] Please provide spot elevations for all lot corners and at the PC's of comer lots as well. Acknowledged, corrected — see Rough and Final Grading Plans. Number: 136 Created: 2/13/2007 [2/13/07] Call out the detail and sheet # for the modified curb cut and sidewalk chase. Modified curb cut detail has been removed and replaced with standard details D12 and D13 from the "City of Fort Collins Stormwater Utility -Storm Drainage Design Criteria and Construction Standards" manual. Number: 137 Created: 2/13/2007 [2/13/07] Please label all slope ratios. Slope ratios have been added. Number: 138 Created: 2/13/2007 [2/13/07] What is the dark line shown on the SW corner of Overland and West Elizabeth - a retaining wall or fence? Wasn't included in the legend... This line is a wall. Please see Landscape Plans for wall detail. Number: 139 Created: 2/13/2007 [2/13/07] Need to include the box culvert design in the utility plan set and label the sheets as part of this set. Box Culvert design has been added to the Utility Plan set —see sheets Sl -S4. Page 9 of 17 [2/15/07] Minimum cover requirements are not being met. I will talk to Rick Richter in Pavement Management next week when he's back from vacation for some ideas. After meeting with City staff on this issue is was agreed that, with a variance, 15 "-18" of cover over the pipes to the bottom of subgrade would be acceptable. Minimum cover over the storm pipes for this project is 18" to bottom of subgrade. Please see the variance request included with this submittal titled "Minimum Utility Cover". Number: 163 Created: 2/15/2007 [2/15/07] Need to show this line in the street cross sections. The 16" waterline has been is shown, in relation to the street cross section, on the 16" waterline detail sheet. This line runs perpendicular to the street cross sections so does not show upon the Overland Trail Cross Section sheet. Waterlines running with the street have been added to the Overland Trail cross -sections. Number: 164 Created: 2/15/2007 [2/15/07] Please provide the FCLWD signature block on these sheets. Signature block has been added. Topic: Utility Plan - Bridge Design Number: 160 Created: 2/15/2007 [2/15/07] Eliminate the parkway and construct a 10' attached walk. Design the bridge in accordance with city standards. Please provide all structural calcs. More comments to follow when a specific, detailed design has been submitted. Sidewalk has been redesigned and structural sheets Sl-S4 have been added to the Utility Plans set. Number: 161 Created: 2/15/2007 [2/15/07] Please see attached comments from Jin Wang. Please see sheets Sl -S4 for revisions. Number: 166 Created: 2/15/2007 [2/15/07] Please see redlines for other comments. Redlines have been reviewed and changes have been made. Topic: Utility Plan - Cover Number: 145 Created: 2/15/2007 [2/15/07] Correct the index (see redlines) and add the box culvert design to this set and number as part of the set. Box Culvert structural design is now part of the Utility Plan set — see sheets S!-S4. Topic: Utility Plan - Cross Sections Number: 154 Created: 2/15/2007 [2/15/07] Missing information - please refer to LCUASS. Page 8 of 17 Number: 146 Created: 2/15/2007 [2/15/071 Remove "to be vacated upon the completion of necessary drainage improvements". That is a separate process if not vacating by this plat. Acknowledged, removed. Number: 147 Created: 2/15/2007 [2/15/07] Remove the word "permanent" from the 10' utility easement. All easements are permanent until vacated. Acknowledged, removed. Number: 167 Created: 2/15/2007 [2/15/07] Please see redlines contained within the utility plan set. Redlines have been reviewed and addressed. Department: Engineering Issue Contact: Dan DeLaughter Topic: Plat Number: 90 Created: 4/19/2006 [2/13/07] Please place a signature line on the plat for any entity or persons having an easement dedicated to them. [4/19/06] The Ditch Company should sign all applicable plan sheets, as well as the plat. Acknowledged. Number: 98 Created: 4/20/2006 [2/13/07] [4/20/06] Tech. Services Comments: 1. Easements need to be locatable on the plat. 2. Note the origin of ROW dedication for Overland Trail. 3. Fix overlapping text. Acknowledged, corrected. Department: Engineering Issue Contact: Susan Joy Topic: Utility Plan Number: 133 Created: 2/13/2007 [2/13/07] Please complete and submit the checklist in Appendix E4 for the next round and include all items in the design. Any item left off the plans required by the appendix or LCUASS will become a comment for the next round Checklist included. Number: 150 Created: 2/15/2007 [2/15/07] See LCUASS and E4 for other requirements missing from the plans. More detailed comments to follow when more information is given and the plans become legible. Additional information has been added as per LCUASS and E4. Topic: Utility Plan - 16" Waterline Number: 162 Created: 2/15/2007 Page 7 of 17 Please call Terry, at 226-3104, ext. 104, if you have any questions or require additional information. Acknowledged Department: Engineering Issue Contact: Susan Joy Topic: General Number: 144 Created: 2/15/2007 [2/15/07] PFA requires a minimum turning radius of 25' inside and 50' outside. This requirement is not being met in the EA lane. Minimum radius is 30' inside and 50' outside. These are acceptable under PFA's requirements. Department: Engineering Issue Contact: Dan DeLaughter Topic: General Number: 30 Created: 12/29/2005 [2/13/07] The plan sets are still not meeting the requirements set forth in Appendix E6. In some cases, the font is too small to even read let alone review. Please bring the plans up to standard. More comments to follow once the labeling becomes legible. [4/6/06] [12/29/05] Scanability is an issue on many of the sheets. Some line types are too light, some overlapping text problems. Please refer to redlines, Appendix E-6, and talk with J.R. in our technical services department regarding how to clean up the drawings. Fonts and line weights are adjusted to be in compliance with Appendix E6 Department: Engineering Issue Contact: Susan Joy Topic: Plat Number: 140 Created: 2/14/2007 [2/14/07] From Technical Services - Boundary and legal close. Acknowledged. Number: 141 Created: 2/14/2007 [2/14/071 From Technical Services - What are the grey shaded areas - they cover other text. (from engineering - shading will not scan, please remove. See Appendix E6 for other scanning requirements). Shading removed. Number: 142 Created: 2/14/2007 [2/14/07] From Technical Services - Plat must have outer boundary monument at 1400' max distance. Acknowledged,. corrected. Number: 143 Created: 2/14/2007 [2/14/07] From Technical Services - Clearly indicate "Private Streets and Drives" on plat. Acknowledged, corrected Page 6 of 17 Number: 123 Created: 2/12/2007 [2/12/07] Under Detail 2 - LMN ZONE RESIDENTIAL LOT (TYP.), Sheet SP-2, please add the following note: * See PROJECT NOTE 4 (this sheet) for required garage door setback. This should ensure that no future residents would think that their garage door could be set back only. l5' from the back of sidewalk. A minimum 22 setback is required. This note has been added. Number: 124 Created: 2/13/2007 [2/13/07) The leader lines and arrows for the Drainage Easements at the southwest comer of the development, shown on Sheet SP-5 of 5, are misleading and difficult to follow. Acknowledged, corrected. Number: 125 Created: 2/13/2007 [2/13/07] For the sake of clarity, on Sheet SP-5 of 5, please add the PROPERTY LINE/L.O.D. designation to the "new' property line along the rear of the lots in the Ponds @ Overland Trail where the property is to be quit claimed. Acknowledged, corrected. Number: 131 Created: 2/13/2007 [2/13/07] The reference to Project Development Plan in the Title and Title Blocks on the Site Plans is not necessary. These plans should read the same as the Landscape Plans. Acknowledged, corrected. Topic: Utility Plan Number: 108 Created: 4/27/2006 [2/12/07] This note has not yet been added to Sheet SP-3 or L2. [4/27/06] Terry Farrill of the Fort Collins -Loveland Water District & the South Fort Collins Sanitation District made the following comment: A note is to be shown on all sheets relative to the District's existing 36" water line to indicate that all work near the water line or within the District's easement is to be coordinated with the District prior to commencing work. Please contact Terry, at 226-3104 x 104, if you have questions or require additional information. Note has been added. Number: 121 Created: 2/12/2007 [2/12/07] Terry Farrill of the South Fort Collins -Loveland Water District offered the following comment: The existing 3/4 inch water tap, generally located near Tract A (the existing house), is to be abandoned in accordance with District requirements. All costs associated with the abandonment is the responsibility of the owner/developer. Page 5 of 17 The note, in its entirety, is showing on Sheet L2 of 5 Number: 127 Created: 2/13/2007 [2/13/07] The signage as shown on Detail 8 - ENTRY FEATURE on Sheet L3 of 5 will not be approved with approval of the Landscape Plans. The allowable signage will only be approved through the review of signage against the Sign Code as administered by the Zoning Department. This is a separate process from the Project Development Plan/Final Plan review and approval. Acknowledged. The Entry Feature Detail has been removed. There is a planting plan for the entry shown on L3 only. Number: 176 Created: 2/16/2007 [2/16/07] A copy of comments received from Tim Buchanan, the City Forester, is attached to this comment letter. Acknowledged, we did receive his letter and have addressed those comments on the Landscape Plan. Number: 177 Created: 2/16/2007 [2/16/07] Dana Leavitt, the City's Environmental Planner, indicated that the Tree Protection Notes must be on the "demolition" plan. Tree Protection Notes have been added to the Demolition Plan. Number: 178 Created: 2/16/2007 [2/16/07] There appear to be conflicts with trees to remain & protected and trees to be removed. Tree removal conflicts have been resolved. Topic: Plat Number: 129 Created: 2/13/2007 [2/13/071 It is doubtful the shaded notes on the plat sheets will be acceptable for recording the plat. Please contact J.R. Wilson, at 221-6588, to discuss this concern. Shading removed Number: 130 Created: 2/13/2007 [2/13/07] Are the Pleasant Valley & Lake Canal Company and the Fort Collins -Loveland Water District/South Fort Collins Sanitation District signature blocks required on Sheet 3 of 3 of the Subdivision Plat? Signature blocks have been removed from sheet 3 of 3 of Plat Topic: Site plan Number: 122 Created: 2/12/2007 [2/12/07] Please remove the reference to (FA-1 Existing Zoning) in the Land Use - Entire PDP table under SITE DATA TABULATIONS on Sheet SP-2 of 5. The annexation of this property has been completed and the FA-1 zoning no longer exists here. FA-1 zoning note has been removed. Page 4 of 17 [2/12/07) The referenced signature block was removed from Sheet L2 of the Landscape Plan, as requested, but has now been added to Sheet SP-3 of the Site Plans. Why has it been added to this sheet? It is not needed. [4/27/06) Remove the Fort Collins -Loveland Water District, South Fort Collins Sanitation District signature block from Sheet L2 of 5 of the Landscape Plans. Signature block has been removed from Sheet L2 of 5. Number: 102 Created: 4/27/2006 [2/12/07] The PROPERTY BOUNDARY/L.O.D. reference on the north property boundary, above Lots 1 & 2 & Tract E just north of West Elizabeth Street, must include /CITY LIMITS, as this line still reflects the City's limits in this area. City Limits has been noted as requested. [4/27/06] On Sheet L4 of 5 of the Landscape Plans, the north property boundary is now the PROPERTY BOUNDARY/L.O.D./CITY LIMITS and the reference to CITY LIMITS must be removed from the south property boundary. The annexation for the Minatta Property is complete. City Limits note has been removed as requested. Number: 104 Created: 4/27/2006 [2/12/07] The PROPERTY BOUNDARY/L.O.D./CITY LIMITS should be identified along the north property boundary on Sheet L5. Also, the new PROPERTY BOUNDARY/L.O.D. should be identified along the south property boundary where the properties have been quit claimed to the 7 lots in the Ponds @ Overland Trail. [4/27/06] On Sheet L5 of 5 of the Landscape Plans ... same as comment # 102. The PROPERTY BO UNDARYIL.OffICITY LIMITS and PROPERTY BOUNDARYIL.O.D. lines have been corrected. Number: 105 Created: 4/27/2006 [2/12/07] Just repeated to reiterate this requirement. [4/27/06] On Sheet L4 of 5, the trail from Fiore Court to Sunflower Drive should be a 6' wide concrete surface trail. It becomes a 6' wide soft surface trail west of Sunflower Drive to the west property boundary. Acknowledged, this change has been made. Number: 114 Created: 2/6/2007 [2/6/07] The LANDSCAPING ASSURANCES note on the Landscape Plan references the "current" phase. What does this mean and how can it be administered, especially since there are no identifiable phase lines shown on the Landscape Plans? There are now two phases and have been identified on all plan sets the LANDSCAPE ASSURANCES note now is applicable as written. Number: 126 Created: 2/13/2007 [2/13/07] Part of the water line easement note on Sheet L2 of 5, middle of the sheet just above the LEGEND, is missing. Page 3 of 17 [2/9/07] Doug Moore's comments have been carried forward for Architectural Standards, adding the LOD around the buffer, inclusion of prairie dog protection measures during construction in the development agreement and wildlife letter for potential home owners. Acknowledged. Number: 116 Created: 2/12/2007 [2/12/071 Existing Conditions Plan in utility plan set shows trees that are to be removed that on the Landscape Plan are to be reserved. Resolve conflict. Tree removal has been corrected and is consistent on all plans. Number: 117 Created: 2/12/2007 [2/12/07] Show Limits of Development (LOD) on Existing Conditions Plan. LOD has been corrected and is shown on the Existing Conditions plan. Number: 118 Created: 2/12/2007 [2/12/07] Add tree protection standards to Existing Conditions Plan. Tree protection standards have been added to the Existing Conditions Plan. Department: Current Planning Issue Contact: Steve Olt Topic: Grading plans Number. 180 Created: 2/16/2007 [2/16/07] Wes Lamarque of the Stormwater Utility indicated that there must be detailed site grading shown on the grading plans for the single-family homes. Please see Final Grading Plan sheets for detailed grading information Department: Current Planning Issue Contact: Dana Leavitt Topic: Grading plans Number: 119 Created: 2/12/2007 [2/12/071 LOD needs to be shown and labeled on grading plan. LOD line has been included and labeled on grading plan. Number: 120 Created: 2/12/2007 [2/12/07] Grading is shown within the buffer zone, which is outside of the LOD. Buffer zone and existing trees are meant to be preserved. If there are no other alternatives to the proposed grading, then tree mitigation will need to be implemented. Tim Buchanan will need to be contacted to address this issue. Otherwise, pull grading back from buffer zone. Tim Buchanan has completed a site visit. Tree mitigation has been implemented per Tim's direction. Department: Current Planning Issue Contact: Steve Olt Topic: Landscape plan Number: 100 Created: 4/27/2006 Page 2 of 17 June 6, 2007 Steve Olt City of Fort Collins — Current Planning 281 North College Avenue Fort Collins, CO 80522 RE: Bella Vira — Final Plans 2Id Submittal Project No.: 2427 Dear Steve: We offer the following responses to Staffs comments for Bella Vira - Final Plans (our responses are in italics): ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: Building plan Number: 128 Created: 2/13/2007 [2/13/07] As part of the Final Plan review there must be a Building Elevation sheet (24" x 36"), with 4-sided elevations, for the proposed 25 multi -family buildings closest to Overland Trail. Just the colored 11" x 17" sheets showing the front and rear elevations are not sufficient to review, approve, and record. These elevations are different than the required Architectural Standards information for the single-family homes on the western portion of the development. Multi family elevations (4 sided) created per Current Planning specifications and included with submittal. Topic: General Number: 113 Created: 2/6/2007 [2/6/07] Where are the "updated" Architectural Standards requested by Natural Resources? Did not get a copy with the Final Compliance submittal. Three (3) copies of the standards, which relate most to the single-family homes on the west end of the development, must be submitted as soon as possible. The Final Plans cannot be approved and recorded until the standards are accepted by the City. Updated Architectural Standards are included on Sheet LI of Landscape Plan as agreed upon with Dana Leavitt. Number: 179 Created: 2/16/2007 [2/16/07] Dana Leavitt, the City's Environmental Planner, indicated that the Limits of Development must be shown on the Site, Landscape, and Utility Plans. Limits of Development Line has been added to Site, Landscape and Utility Plan set sheets. Department: Current Planning Topic: General Number: 115 Issue Contact: Dana Leavitt Created: 2/9/2007 Page 1 of 17