HomeMy WebLinkAbout1504 REMINGTON ST. RENOVATION - SPAR - 33-09 - CORRESPONDENCE - (8)OCCUPANT LOAD SIGN Any room or space having an occupant load of 50 or more and which is used for assembly purposes, shall have the capacity of the room posted in a conspicuous place on an approved sign near the main exit or exit access doorway from the room or space. Such sign shall be maintained legible by the owner or the owner's authorized agent and shall indicate the number of occupants permitted for each room use. PLEASE NOTE: If any area inside the structure is used for assembly purposes for 50 or more people, it will be considered an Assembly Occupancy, which will kick in other IFC requirements. 2006 International Fire Code 1004.3 Department: Transportation Planning Issue Contact: Jennifer Petrik Topic: General Number: 1 Created: 10/6/2009 It is recommended detached sidewalks be installed per Larimer County Urban Area Street Standards along Lake Street. This is an area of high pedestrian traffic. A high percentage of visitors are likely to arrive via sensible modes (alternative modes) of transportation. Providing safe pedestrian connectivity increases the safety of pedestrians arriving and leaving the side as vyell increases pedestrian connectivity in the area. Number: 2 cun ct Created: 10/6/2009 [10/6/09] It is recommended that bicycle facilities (bike racks) be provided on a hard surface close to the entrance and preferably in a place protected from the elements. This is a facility that will likely see a high number of visitors arriving and departing by bicycle and by foot. Providing bicycle facilities will encourage visitors to park in an area that is intended for bike parking. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterlWastewater Number: 9 Created: 10/6/2009 [10/6/09] The existing water service is a 3/4-inch. If additional capacity is needed, development fees and water rights will be due prior to building permit (or if no permit, prior to doing the work). Number: 10 Created: 10/6/2009 1 1 [10/6/09] Will a fire line be required? If so, provide utility plan for review and approval. w �WLC 2. Be sure and return all of your redlined plans when you re -submit. 1 i L _ I If you have any questions regarding these issues or any other issues related to this projectµ;. 40k please feel free to call me at (970) 221-6750.�✓i2 S Sincerely, Emma McArdle City Planner Page 2 i� STAFF PROJECT REVIEW City of Fort Collins Brian Chase, Director of Facilities Management CSU Date: 10/7/2009 Staff has reviewed your submittal for 1504 REMINGTON STREET RENOVATION - SITE PLAN ADVISORY REVIEW, and we offer the following comments: ISSUES: Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 3 Created: 10/6/2009 AUTOMATIC FIRE SPRINKLERS Will the entire building be equipped with auto fire sprinklers? Where will the FDC be located (location needs to be approved by PFA in advance). Number: 4 Created: 10/6/2009 WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. PLEASE NOTE: The closest fire hydrant is located in the northwest quadrant of Lake/Remington streets. 2006 International Fire Code 508.1 and Appendix B Number: 5 Created: 10/6/2009 ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a miniinum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable.) 2006 International Fire Code 505.1 Number: 6 Created: 10/6/2009 KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 Number: 7 Created: 10/6/2009 COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM With the production of grease -laden vapors, an approved, automatic fire -extinguishing system shall be provided for the protection of commercial -type cooking equipment: 2006 International Fire Code 904.2.1; 609.2; 904.11.2 Number: 8 Created: 10/6/2009 Page 1