HomeMy WebLinkAboutAIR CARE COLORADO - PDP - 2-10 - CORRESPONDENCE - (13)to construction. All floodproofing requirements identified in Section 10-38 of City Code must be ' satisfied before the Floodproofing Certificate may be approved. 8. An as -built FEMA Floodproofing Certificate or FEMA Elevation Certificate must be provided immediately after construction is complete. A Certificate of Occupancy (C.O.) will not be issued for the property without an approved Floodproofing Certificate or Elevation Certificate. 9. The floodproofing guidelines and development review checklist for floodplain items can be found on our website at hftp://www.fcgov.com/stormwater/fp-forms.php. 10. The floodplain administrator for Boxelder Creek is Brian Varrella; 416-2217. 11. A drainage and erosion control report and construction plans are required and must be prepared by a Professional Engineer registered in Colorado. The applicant indicated that this development was originally approved in the County and that the drainage system was designed to convey the runoff to Boxelder Creek without detention. 12. Normally, onsite detention is required with a 2 year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. Documentation needs to be provided to determine if discharge to Boxelder Creek without detention can be allowed. In addition, the rainfall intensity needs to be checked to see if it is the correct one. Larimer County does require the use of the Fort Collins rainfall intensity curves in the GMA before the site was annexed, but since the study was prepared a quite a long time ago, a different intensity curve may have been used. 13. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). 14. The design of this site must conform to the drainage basin design of the Boxelder/Cooper Slough Master Drainage Plan as well the City's Design Criteria and Construction standards. 15. The city wide development fee is $4,420/acre ($0.1015/sq.ft.) for new impervious area over 350 sq.-ft. No fee is charged for existing impervious area. This fee is to be paid at the time each building permit is issued TRANSPORTATION PLANNING Jennifer Petrik, (970)416-2471, ipetrik fc oq v.com 1. Bicycle facilities are required. 2. Detached sidewalk along frontage road is required per Larimer County Urban Area Street Standards. 3. Section 3.5.3 of the Land Use Code describes the requirements and shows examples of the required building orientation to a connecting walkway. The City of Fort Collins requires direct pedestrian connection from the sidewalk to the building without crossing a drive isle. The current building location is to avoid creating an "Island". WASTEWATER Roger Buffington, (970)221-6854, rbuffington anfcgov.com Water and sewer service for this area are provided by the ELCO Water District and Boxelder Sanitation District. of Fort Collins 6. ADDRESS NUMERALS - Address numerals shall be visible from the street fronting the property, IFN and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 2006 International Fire Code 505.1 7. FIRE LINE REQUIREMENT - Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. NFPA 13 (2007) 23.1.3 8. KEY BOXES REQUIRED - Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved locations) on every new building equipped a required fire -sprinkler system or fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 9. FIRE DEPARTMENT CONNECTION - Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2_and PFA Fire Prevention Bureau Policy 10. IDENTIFICATION OF FIRE PROTECTION EQUIPMENT - Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, electrical rooms, sprinkler risers and valves, or other fire detection, suppression or control elements shall be identified for the use of the fire department. 2006 International Fire Code 510.1 11. TURNING RADII - The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 503.2.4 and Appendix D103.3 12. HAZARDOUS MATERIALS - Toxic, corrosive, or reactive materials, or flammable/combustible liquids (as defined in the Intematioal Fire Code) if used, stored, or handled on site, must have a Hazardous Materials Impact Analysis (HMIA) completed and supplied to the Planning Department and the Fire Department. (What do you have? How much? How do you prevent it from being a public threat?) FCLUC3.4.5 STORMWATER Glen Schlueter, (970)221-6065, aschlueter(a)fcaov.com 1. The parcel is located in the FEMA-regulatory 100-year flood fringe of Boxelder Creek, and is subject to the requirements of Chapter 10 of City Code. 2. Construction of new non-residential development is permitted in the flood fringe. All new structures must be elevated or floodproofed at least 18 inches above the base flood elevation (BFE). New basements are prohibited in the flood fringe unless floodproofed. 3. All HVAC (including duct work), electrical, and mechanical equipment (including air conditioners) must be elevated or floodproofed at least 18 inches above the BFE. 4. All floodproofed structures must be constructed with flood resistant materials below the regulatory flood protection elevation (RFPE). This elevation is determined to be 18 inches above the BFE on new non-residential structures. If the flood depth surrounding the structure exceeds 3 feet, the structure cannot be floodproofed and must be elevated to or above the RFPE. 5. Non-structural development is permitted in the flood fringe. 6. All site work in the flood fringe must be preceded by an approved floodplain use permit and $25 fee. All structures must be individually permitted — $25 fee will be required for each individual structure, permit. 7. If floodproofing will be utilized in lieu of elevating, a FEMA Floodproofing Certificate must be prepared by a professional engineer or architect licensed to practice in the State of Colorado prior 5 FortCollins ( 6. Will need a C-1 Form and One -Line Diagram submitted POUDRE FIRE AUTHORITY Carie Dann, (970)416-2869, cdann(a)poudre-fire.org 1. BUILDING AREA - Buildings of Type V construction that exceed 5,000 square feet shall be fire contained or fire sprinklered. 2006 International Fire Code New Table 903.1_ and Section 702 2. S1 OCCUPANCY FIRE SPRINKLERS - An automatic fire sprinkler system shall be provided throughout all buildings used as repair garage (S1 Occupancy) in accordance with the International Building Code, as follows: (2) One-story buildings with a fire, area containing a repair garage exceeding 12,000 square feet. 2006 International Fire Code 903.2.8.1 3. H OCCUPANCY FIRE SPRINKLERS - An automatic fire sprinkler system shall be installed in Group H occupancies. 2006 International Fire Code 903.2.4.1 4. REQUIRED ACCESS - Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval rigor to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. Have appropriate maintenance agreements that are legally binding and enforceable. Be designated on the plat as an Emergency Access Easement. . Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structures is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 Intemational Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D 5. WATER SUPPLY - Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B 1l Fort Collins ENGINEERING Susan Joy, (970)221.6581, siov(a)fcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see http://www.fcgov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). 6. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. It is unknown at this time whether or CDOT has the row it requires for the frontage road or if there are additional utility easements behind the row required. 7. This site is adjacent to CDOT roadway and all access to the site is governed by an access control plan. The access control plan will need to be followed and implemented with any project. Plans will be routed to CDOT for review and approval and the applicant may need to obtain access permits from CDOT. 8. Utility plans will be needed for this project. 9. A development agreement will be done with this project. 10. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. 11. Driveways must line up with those across the street or meet minimum separation requirements. It appears that the existing driveway access is shared with the property to the south so access to the neighboring property must be maintained with additional access easements and a drive aisle constructed to this property's property line for future connection. 12. Street sidewalks, parkways, sidewalk connections to the building, and parking stalls, drive aisles, and setbacks must meet minimum requirements. 13. It appears that you are removing the right turn lane into your driveway? If this is so, the TIS, CDOT and the property owner to the south have to agree to this and you will need to vacate the row. There is a separate TDRF to do this and it requires council approval. Please plan an additional 3 months for that process to be completed. LIGHT AND POWER Robert Irish, (970)224-6167, rirish cDfcgov.com 1. Existing 3-phase electric facilities existing along the frontage road adjacent to this property 2. Any relocation or modification to existing electric facilities will be at the expense of the owner 3. Electric Capacity Fee & Building Site charges will apply 4. Transformer location needs to be within 10' of an all weather driveover surface 5. Transformer needs to have clearances of Son the sides and back and 8' in the front 3 City of F6rt Collins 4. Please see the Development Review Guide at www.fcgov.com/dig. This online guide features a color -coded flowchart with comprehensive, easy to read information on each step in the process for Project Development Plans (PDPs). This guide includes links to just about every resource you need during development review. - Project Specific Comments: 1. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards and Section 4.21 Commercial District. 2. As discussed at the Conceptual Review Meeting, this development request may need to request several Modification of Standard Requests (LUC, Sect. 2.8.2). You have the option to either request these modifications as part of your overall Project Development Plan, or run them as a separate request. There are benefits to both scenarios: a. Stand Alone Modification of Standards Request — This allows you to get the modifications approved first so you don't spend the time and money getting all the detailed plans completed without knowing if the modifications will even be approved. This request would be processed as a Type 1 application just like the overall PDP. If you would like to pursue this option, let me know and we can discuss submittal requirements. b. Concurrent Modification Requests with PDP — Running the requested modifications and PDP together is also an option. The only draw back is the Hearing Officer may not support the modifications then you would either have to change your plans to meet the standard or be back at square one with a project that was not approved. 3. The Plan as presented at Conceptual Review would need the following Modifications of Standard: a. Section 3.5.3(B)(1) Orientation to a Connecting Walkway b. Section 3.5.3(B)(2) Orientation to Build -to Lines for Streetfront Buildings c. There would be more, but I am assuming that a sidewalk along the frontage road, foundations plantings and the other required landscaping will be added to meet the standards of Article 3. 4. The applicant for this development request is not required to hold a neighborhood information meeting prior to formal submittal of the proposal, but staff always recommends having one. Neighborhood meetings cost you nothing and offer an informal way to get feedback from your surrounding neighbors and discover any potential hiccups prior to the formal hearing. If you would like to have a neighborhood meeting, please contact Emma McArdle, at 221-6206, to assist you in setting a date, time, and location. Emma, and possibly other City staff, would be present to facilitate the meeting. 5. 1 will have more detailed comments on the PDP once I have more detailed plans to review. 6. Please contact me with any questions along the way. CURRENT PLANNING — ENVIRONMENTAL PLANNER Dana Leavitt, (970)224-6143 1. Green building and design is encouraged. Please contact Gary Schroeder at (970)221-6395 if you have questions about the City's Integrated Design Assistance Program (IDAP). 2. Please see the attached documents regarding revisions to the Land Use Code pertaining to landscape standards for PDPs. 2 art Collins CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: September 14, 2009 Item: Envirotest Vehicle Emissions Testing Applicant: Jim Mokler Brian Ojala, AIA IBP 14 Corporation Entasis Group, LLC 123 N College Ave, Suite 350 12365 Huron St #400 Fort Collins, CO Westminster, CO 80234 Land Use Data: This is a request for a vehicle emissions testing facility to be located at Lot 16 of Interchange Business Park. This is in the Commercial (C) Zone District. The use is considered a "vehicle minor repair, servicing and maintenance establishment" and is subject to a Type 1 (administrative review) process and public hearing in the C zone district (Land Use Code, Section 4.21 (B)(2)(c)l 1). The applicants also intend to replat the property, moving the southwest lot line 60' to the southwest, increasing the lot size by approximately 21,600 square feet. Comments: ZONING Contact: Gary Lopez, (970)416-2338, glopez&fcgov.com 1. Zoned C. 2. Diagnostic engine work which is performed at the facility will fall under the use category of "Vehicle minor repair, servicing and maintenance". This is allowed subject to a Type 1 review. 3. The property appears to be within 114 mile of 1-25. Therefore, its subject to compliance with the I- 25 Corridor standards in Section 3.9 of the Land Use Code. This section has requirements for such things as building placement, landscaping and building design. CURRENT PLANNING Contact: Emma McArdle, (970)221-6206, emcardle(@fcgov.com General Comments: 1. The submittal requirements are available on the Current Planning website, http://fcqov.com/currentolanning, see the Submittal Requirement tab on the right. When you are ready to submit, please make an appointment with Neighborhood and Building Services at, (970)221-6750. 2. The request will be subject to the Development Review Fee Schedule that is available in the Current Planning Department office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal and this fee is paid directly to the Engineering Department. 3. The entire Fort Collins Land Use Code (LUC) is available for your review on the web at http://www.colocode.com/ftcollins/]anduse/begin.htm. of F6rtiCollins September 18, 2009 Jim Mokler IBP 14 Corp. 123 N College Ave, Suite 350 Fort Collins, CO Brian gala, AIA Entasis Group, LLC 12365 Huron St #400 Westminster, CO 80234 Dear Jim and Brian, Current Planning 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov. com/currentplanning Attached, please see a copy of Staffs comments concerning the request referred to as Envirotest Vehicle Emissions Testing Facility, which was presented before the Conceptual Review Team on September 14, 2009. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments please feel free to contact me at 221-6206. Sincerely, Emma McArdle City Planner CC Gary Lopez, Zoning Susan Joy, Engineering Rob Irish, Light and Power Carte Dann, PFA Glen Schlueter, Stormwater Jennifer Petrik, Transportation Planning Roger Buffington, Wastewater