HomeMy WebLinkAboutSOUTH TRANSIT CENTER - PDP - 9-10 - REPORTS - RECOMMENDATION/REPORTSouth Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 19
• Transit facilities without repair or storage are permitted in the (C) Commercial
District, subject to an administrative review.
• The South Transit Center, PDP complies with the applicable General
Development Standards of Article 3, with the exception of:
- Two Modification of Standard Requests:
1. Section 3.5.3(B)(1) Orientation to a Connecting Walkway, and
2. Section 3.5.3(B)(2) Orientation to Build -to Lines for Street Front
Buildings
- One Alternative Compliance Requests:
1. Section 3.2.2(K)(2) for Nonresidential Parking Requirements
• The South Transit Center, PDP complies with the land use and development
standards of the Division 4.21 C, Commercial District.
RECOMMENDATION:
Staff recommends the following:
• Approval of the Modification of Standard Requests to:
- Section 3.5.3(B)(1) Orientation to a Connecting Walkway, and
- Section 3.5.3(B)(2) Orientation to Build -to Lines for Street Front Buildings
• Approval of the Alternative Compliance Request to:
- Section 3.2.2(K)(2) for Nonresidential Parking Requirements
0 Approval of the South Transit Center, PDP #9-10
e
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 18
such a standard would render the project practically infeasible.
This standard would require the transit facility to be located no more than 15'
from the street right-of-way. Unlike a typical lot that has public street frontage
on one or more sides, this site is located at the terminus of Fossil Boulevard so
has very limited right-of-way frontage. This limited frontage is located at the
southeast corner of the site. A primary function of the transit center is to serve
as the southern terminus to the Mason Corridor BRT route. To accomplish this
it must directly connect to the guideway located at the northwest corner of the
site. This public facility must also accommodate visitor and rider connectivity
from not only the public street frontage but from the adjacent bike trail, the
Mason Corridor, and from potential future development to the east. So, rather
than locating the building at the southeast corner of the site as the strict
application of the standard would require, we have centrally located the bus
platform facility to efficiently work with the BRT guideway design, the bike trail,
and separated visitor park -and -ride spaces. Strict application of this standard
would render the project infeasible as a primary public facility addressing
important community needs outlined in the city's Comprehensive Plan
regarding transportation.
ii. Staffs Evaluation of Applicant's Request
Staff has determined that the proposed modification to Section 3.5.3(B)(2),
regarding orientation to build -to lines for streetfront buildings, is not detrimental
to the public good and "strict application of the standard sought to be modified
would result in unusual and exceptional practical difficulties, or exceptional or
undue hardship upon the owner of such property" (Section2.8.2(H)(3)). The
street right-of-way, that the building should be 15' or less away from, is only
present along 54' of the southeast corner of the site. This limits the location of
the structure to,that corner of the site. This corner is the lowest elevation on
the site making its most functional use be the detention area and the
functionality would be limited because the bus bays would not be able to
surround the transit facility with only 15 feet of space around the building.
iii. Staffs Recommended Action
Staff recommends approval of the Modification of Standard Request to Section
3.5.3(B)(2) because the plan is not detrimental to the public good and "strict
application of the standard sought to be modified would result in unusual and
exceptional practical difficulties, or exceptional or undue hardship upon the
owner of such property." %
6. Findings of Fact/Conclusion:
In reviewing the request for the South Transit Center, PDP, Staff makes the following
findings of fact:
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 17
Staff has determined that the proposed modification to Section 3.5.3(B)(1),
regarding orientation to a connecting walkway, is not detrimental to the public
good and promotes the general purpose of the standard equally well or better
than a plan that complies with the standard. The entire purpose of this site is to
safely and conveniently provide alternative transportation options, and as such
the most appropriate design of the South Transit Center facility is to be centrally
located to the bus bays. The plan provides designated walks for pedestrians
directly to the station, but crossing the bus drive aisle is unavoidable without
limiting the functionality of the transit station.
iii. Staffs Recommended Action
Staff recommends approval of the Modification of Standard Request to Section
3.5.3(B)(1) because the plan is not detrimental to the public good and "the plan
as submitted will promote the general purpose of the standard for which the
modification is requested equally well or better than would a plan which
complies with the standard for which a modification is requested.
B. Modification of Standard to Section 3.5.3(B)(2) Orientation to Build -to Lines for
Streetfront Buildings.
This section requires buildings "be located no more than 15' from the right-of-way
of an adjoining street if the street is smaller than a full arterial or has on -street
parking." The only public street that adjoins this site is Fossil Boulevard, which is
a local street (smaller than a full arterial) as designated by the Master Street
Plan. The South Transit Center building should be no more than 15' from Fossil
Boulevard based on this standard.
i. Applicant's Modification Request
Build -to lines based on a consistent relationship of buildings to the street
sidewalk shall be established by development projects for new buildings
and, to the extent reasonably feasible, by development projects for additions
or modifications of existing buildings, in order to form visually continuous,
pedestrian -oriented streetfronts with no vehicle use area between building
faces and the street.
Applicable Criteria from Section 2.8.2 Modification Review Procedures:
(3) The granting of a modification from the strict application of any standard
would, without impairing the intent and purpose of this Land Use Code,
substantially alleviate an existing, defined and described problem of city-
wide concern or would result in a substantial benefit to the city by reason
of the fact that the proposed project would substantially address an
important community need specifically and expressly defined and
described in the city's Comprehensive Plan or in an adopted policy,
ordinance or resolution of the City Council, and the strict application of
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 16
streetfront buildings, cannot be met as written without compromising the
function of the South Transit Center.
For consideration of the modification request, we submit the following findings
for your review:
3.5.3(B)(1) — Orientation to a Connecting Walkway. At least one main
entrance of any commercial or mixed -use building shall face and open directly
onto a connecting walkway with pedestrian frontage.
Applicable Criteria from Section 2.8.2 Modification Review Procedures:
Section 2.8.2(H)(2) The plan as submitted will promote the general
purpose of the standard for which the modification is requested equally
well or better than would a plan which complies with the standard.
This standard is intended to provide direct pedestrian connectivity from the
public frontage (considered to be the primary origination of pedestrian traffic) to
the building without crossing an intervening driveway. As a primary function of
the transit center, this facility must accommodate pedestrian connectivity from
not only the public street frontage but from the adjacent bike trail and from
potential future development to the east. So, rather than focusing a building
entrance toward a single connecting walkway, the site centrally locates the bus
platform areas with direct pedestrian connections to the bike trail, the adjacent
public street, and the east property line.
The station building and central platform area is completely surrounded by bus
drive aisles and bus bays. Although this requires each of these pedestrian
connections to cross the bus drive areas, this orientation provides better and
safer pedestrian conditions than alternative plans. By circulating the buses
around a central platform rather than through multiple bus bay islands, we
reduce the number of times a pedestrian needs to make these bus drive
crossings that are inherent in design of multiple bays. Once a pedestrian
arrives from their origination point (parking lot, street sidewalk or bike trail) they
are able to circulate from station -to -bay or from bay -to -bay without crossing any
additional drives.
Also, the bus drives are much safer to cross than a typical visitor drive or
parking lot aisle. The bus operators are keenly aware of pedestrian/rider
patterns and operate at very low speeds in the station areas. The site is
configured to provide direct pedestrian connectivity from the bike trails and
street sidewalk to the platform and building by only crossing the bus drive, but
no intervening parking lot drive aisle or publicly -used drive.
ii. Staffs Evaluation of Applicant's Request
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 15
facility. We submit that the granting of the modification requests would not be
detrimental to the public good, and would like to offer the following
information specifically regarding each request:
Modification of Standards Requests - Section 3.5.3.(B)(1) and (2)
The standards under 3.5.3 Mixed -Use, Institutional and Commercial Buildings
are indicated with the following purpose:
Purpose. These standards are intended to promote the design of an urban
environment that is built to human scale to encourage attractive street
fronts and other connecting walkways that accommodate pedestrians as
the first priority, while also accommodating vehicular movement.
The sheer nature of the transit hub is to provide access for the public to the
BRT corridor and multiple Transfort bus routes. The station is a starting point
and terminus for the Mason Corridor BRT, south city and regional Transfort
routes, and multiple Transfort route transfers. The users of the Transit Center
will include:
- riders from the BRT or Transfort routes making transfers,
- riders driving by car to the park -and -ride lot to use the services,
- bicyclists or pedestrians from the adjacent city bike trail,
- bicyclists from the adjacent public street (located at the southeast
corner of the property), or
- pedestrians from this public street or from a future redeveloped parcel
east of the site.
As such, the station needs to be designed to efficiently accommodate the many
bus routes, but also must well accommodate pedestrian connections from
many locations in addition to the street front.
The site itself is uniquely situated to provide this purpose well. It is directly
adjacent to both the city bike trail and the proposed Mason Corridor route. It is
also served from the south by a public street, Fossil Boulevard, which then
connects directly to a future signalized intersection at College Avenue.
However, the site serves as a terminus to Fossil Boulevard, so has only limited
street frontage. Rather than a typical, lot that has significant primary street
frontage from which pedestrians, bicycles and vehicles enter and exit,
this lot has:
1) limited street frontage, and
2) must equally accommodate pedestrians, bicycles and vehicles
from the northwest (trail and BRT), southwest (trail), southeast
(street), and east (future development parcels), not just the street.
As such, the two Land Use Code standards 3.5.3(B)(1) regarding orientation to
a connection walkway and 3.5.3(B)(2) regarding orientation to build -to lines for
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 14
d. Base and top Treatments. All facades shall have a recognizable base and
top according to this section. The structure proposed has an articulated
base of ground face CMU with a textured belt on top of it. The top is
accentuated by a sloping roof.
G. Section 3.6.1 — Master Street Plan
All development plans that are adjacent to a state or federal highway shall
provide the access design facilities, including supporting circulation facilities,
identified within any applicable adopted access control plans, when such
facilities are needed because of the development plan.
The South College Corridor Access Control Plan designates an "access
circulator" to be located on the east side of this site. Its purpose is to give the
parcels to the north (Spradley Barr Dealership) and east (vacant land) access to
the signal that will ultimately be located at Fairway Lane and College Avenue.
The PDP has provided an access circulator in accordance with this plan.
H. Section 3.6.6 — Emergency Access
The PDP has been reviewed by emergency access referral agencies, such as
Poudre Fire Authority, and has been determined to have adequate access for
their emergency vehicles.
4. Neighborhood Meeting:
A neighborhood meeting was held on December 2, 2009. Notes recorded at this
meeting are attached.
5. Modification to Applicable General Development Standards
A. Modification of Standard to Section 3.5.3(B)(1) Orientation to a Connecting
Walkway.
This section requires "at least one main entrance of any commercial or mixed -
use building shall face and open directly onto a connecting walkway with
pedestrian frontage." This access shall not cross a vehicle use area.
i. Applicant's Modification Request
As a transit hub and public facility, it will help to achieve many fundamental
goals of City Plan and the Land Use Code. However, the unique needs of such
a facility result in a site plan that while meeting the intent of the code, is unable
to meet two specific requirements. As a result, we are requesting two
modifications of standards in order to facilitate the optimal design for this
0
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 13
b. Windows. Clear anodized, aluminum storefront windows are used
meeting the standards of this section.
iv. Building Color
The building color scheme is compatible with the surrounding area. The
current building stock is made up of white, beige and grey buildings. This PDP
incorporates terra cotta tones in with grey and beige.
F. Section 3.5.3 — Mixed -Use, Institutional and Commercial Buildings
i. Relationship to a Connecting Walkway
This standard requires that "at least one main entrance of any commercial or
mixed -use building shall face and open directly onto a connecting walkway with
pedestrian frontage." The PDP is requesting a Modification of Standard to this
standard under Section 2.2.11(H) of the LUC. This will be discussed further in
Section 5 of this report.
ii. Orientation to Build -to Lines for Streetfront Buildings
This standard requires new buildings to be built within 15' of the right-of-way of
an adjoining street smaller than a full arterial. The PDP is requesting a
Modification of Standard to this standard under Section 2.2.11(H) of the LUC.
This will be discussed further in Section 5 of this report.
iii. Character and Image
a. Site Specific Design. "Building design shall contribute to the uniqueness of
a zone district, and/or the Fort Collins Community with predominant
materials, elements, features, color range and activity areas tailored
specifically to the site and its context." As this area's architectural and
design character is not in compliance with the current standards of the
LUC, the PDP is setting an enhanced standard of quality for future
development and redevelopment in the area.
b. Facade Treatment. The facade meets the criteria of this section as
follows:
- Building bays are broken up and articulated with columns and ribs;
- There are no blank walls exceeding 30 feet; and
- All sides of the building contain consistent materials and design
elements.
c. Entrances. The primary entrance is well defined in accordance with this
section.
South Transit Center— Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 12
Burlington Northern Santa Fe (BNSF) Railroad is directly west of the site oust
beyond the Mason Corridor Trail); and Urban Estate residential neighborhoods
are beyond that. The closest residence is 550+ feet away from the property's
boundary.
The majority of rapid transit buses will access the site from the Mason Street
Extension, which will run adjacent to the Mason Corridor Trail and the BNSF
Railroad; some buses and all other vehicular traffic will access the site from
Fossil Boulevard. The entire bus fleet is expected to be natural gas by the time
this facility opens, limiting the facilities impact on air quality and noise in the
area.
ii. Architectural Character
New developments in or adjacent to existing developed areas shall be
compatible with the established architectural character of such areas by
using a design that is complementary. In areas where the existing
architectural character is not definitely established, or is not consistent with
the purposes of this Land Use Code, the architecture of new development
shall set an enhanced standard of quality for future projects or
redevelopment in the area. Compatibility shall be achieved through
techniques such as the repetition of roof lines, the use of similar proportions
in building mass and outdoor spaces, similar relationships to the street,
similar window and door patterns, and/or the use of building materials that
have color shades and textures similar to those existing in the immediate
area of the proposed infill development. Brick and stone masonry shall be
considered compatible with wood framing and other materials.
A defined architectural character, consistent with this LUC, has not been
established in this area, as the existing buildings were developed over time in
the County. The existing structures in the neighborhood are one to two story,
flat -roofed, buildings with a mix of masonry and metal finishes. The proposed
structure is consistent in terms of height and the east and west elevations tie in
the look of a flat roof (that is actually a butterfly roof, viewed from the north and
south elevation) that provides shelter for the passenger waiting areas. The
proposed building materials enhance the existing building stock's finishes; CMU
block, concrete and accents of grey exposed metal structure are used in
conjunction with wood and panelized rain screens to create a modern addition
to the area. This structure enhances the standard of quality for future
redevelopment in the area.
iii. Building Materials
a. General. As discussed in the previous section, the building materials are
similar to the existing building stock's, but unique articulations are made
enhancing the standard of quality for future redevelopment in the area.
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 11
the minimum size parking lot this type of facility can function with.
Staff has determined that the alternative compliance parking ratio
meets the criteria set forth in this section as it is based on "the
number of expected customers or clients" that will use the facility.
vi. Handicap Parking
a. The PDP provides 6 handicap parking spaces meeting the dimensional
and accessibility requirements of this section.
vii. Parking Stall Dimensions
a. The PDP provides 163 standard parking stalls, which all meet the
dimensional requirements of this section.
viii. Landscaping
a. As discussed previously in Section 3.A.viii.a of this report, 15% of the
interior parking lot is landscaping, the minimum required by this section is
10%.
C. Section 3.2.4 — Site Lighting
The PDP complies with the lighting standards set forth in this section.
D. Section 3.2.5 — Trash and Recycling Enclosures
A trash enclosure is provided on the north end of the parking lot. It is
appropriately sized, is enclosed by a masonry wall and sits on a concrete pad
meeting the standards of this section.
E. Section 3.5.1— Building and Project Compatibility
i. Purpose
The purpose of this section is to ensure that the physical and operational
characteristics of proposed buildings and uses are compatible when
considered within the context of the surrounding area. They should be read
in conjunction with the more specific building standards contained in this
Division 3.5 and the zone district standards contained in Article 4.
The South Transit Center, PDP, proposes one structure on the site, the rapid
transit station. The structure is centrally located to the bus bays, which circle
the building, to provide easy access for all users.
The site is located along the existing Mason Corridor Trail. Commercial uses
exist to the north and south; vacant commercial ground is to the east; the
•
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 10
indicates approximately 170 parking spaces which are considered the
minimum amount needed to serve this facility.
The Land Use Code regulates maximum parking requirements for
nonresidential uses in order to ensure that new development do not
provide excessive amounts of unnecessary and unused impervious
surface site treatments, and to encourage use of alternative transportation
modes. Although the ratio of parking to building size for the transit center
seems high in comparison to other commercial uses, the fundamental
purpose of the park and rid facility is to allow and encourage the
community to park here to utilize alternative modes of transportation to
reach multiple destinations within the city. When this park -and -ride facility
is in place, it will in turn reduce the need for parking in other areas in the
city, so it is important that this parking is right -sized for this need.
As a result, we are requesting alternative compliance allowed in Section
3.2.2(K)(3) that would allow the park -and -ride facility to be sized based on
projected use of this public facility, considered to be a minimum of 169
spaces.
c. Staffs Review of the Alternative Compliance Request
1. Compliance with the general purpose of Section 3.2.2 Access,
Circulation and Parking:
Purpose. This Section is intended to ensure that the parking and
circulation aspects of all development are well designed with
regard to safety, efficiency and convenience for vehicles,
bicycles, pedestrians and transit, both within the development
and to and from surrounding areas. Sidewalk or bikeway
extensions off -site may be required based on needs created by
the proposed development. This Section sets forth parking
requirements in terms of numbers and dimensions of parking
stalls, landscaping and shared parking. It also addresses the
placement of drive-in facilities and loading zones.
The proposed park -and -ride lot meets all the design, landscaping,
safety and multi -modal user requirements of this section of the
code. The number of parking spaces provided does not impact the
projects compliance with the purpose of this section.
2. Compliance with Review Criteria:
The use proposed clearly does not fit any of the options available in
the LUC for non-residential uses. The entire purpose of this facility
is to encourage people to park and utilize public transportation.
Based on analysis done by Transfort the 169 space parking lot is
0
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 9
b. In accordance with this section unobstructed vehicular access is provided
from the public street to the parking lot within the site.
c. All vehicle use areas are proposed to be paved in accordance with this
section.
iii. Parking Lot Layout
a. The parking lot is designed in accordance with the standards of this
section, as it has all of the following: well defined circulation routes for
vehicles, bicycles and pedestrians; conveniently located parking for all
users; landscape islands with raised curbs defining parking aisles and
providing pedestrian refuge areas; and articulated pedestrian walkways
though potential areas of conflict.
iv. Setbacks
a. The parking lot is setback 6' from the east lot line and 15' from the north
property line, exceeding the minimum requirement of 5' designed by this
section.
v. Required Number of Off -Street Spaces for Type of Use
a. There are no complementary uses provided in the LUC to use for the
parking minimum or maximum for this proposed use. The applicants have
prepared an Alternative Compliance Request pursuant to Section
3.2.2(K)(3).
b. Applicant's Alternative Compliance Request
Project Overview
The South Transit Center is a transportation hub located at the south
terminus of the Mason Corridor, a 5.5-mile multi-modal'transportation
corridor running north -south along the Burlington Northern Santa Fe
Railroad through the heart of Fort Collins. Improvements will include a
new 4,500 sq. ft. building, 11 bus bays for the Bus Rapid. Transit and
Transfort fixed -route buses, covered passenger waiting areas, a 169-
space park -and -ride facility, as well as bike and pedestrian trail
connections.
Alternative Compliance Request — Section 3.2.2(K)(3)
The Land Use Code regulates maximum parking requirements for
nonresidential uses in Section 3.2.2(D)(2)(a). However, there is no
comparable or similar land use within these criteria that match a transit
facility. So, we have instead worked closely with Transfort to analyze their
projections for actual use of the facility and to determine parking quantities
needed for the park -and -ride use and trail parking use. Our site plan
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 8
i. Development Standards
a. Safety Considerations. 'To the maximum extent feasible, pedestrians
shall be separated from vehicles and bicycles." Due to the PDP's use it is
impossible to completely separate pedestrians from the bus travel lanes.
There are 4 locations where pedestrian accesses are provided from
sidewalks to the South Transit Center facility, these walkways are
accentuated by colored paving. Walkways through the parking lot are also
articulated by colored paving to call attention to them. Where pedestrians
and bicycle traffic share walkways, the walkways shall be a minimum of 8'
wide. The Mason Corridor Trail is nearly 12' wide to accommodate multi -
modal users.
b. "Curbcuts and ramps shall be located at convenient, safe locations."
Ramps are provided at all crosswalks and pedestrian connections into the
South Transit Center Facility.
c. Convenient bicycle parking spaces of at least 5% of the total parking
spaces shall be provided. The PDP includes 51 covered bicycle parking
spaces located conveniently to the South Transit Center Building. The
minimum required bicycle parking is 9 spaces.
d. Walkways internal to the site "shall be located and aligned to directly and
continuously connect areas or points of pedestrian origin, and shall not be
located ... based on the outline of a parking lot configuration." These
walkways shall be a minimum of 6' wide. The PDP includes a 10' wide,
colored walkway from the parking lot into the South Transit Center facility;
this walkway also serves to provide the sites to the east a connection to
the South Transit Center when they develop at some time in the future.
e. A Transportation Impact Study has been submitted for the overall Mason
Corridor Project. This site was included in that assessment and the
existing infrastructure, with the addition of traffic signals at Mason Street
Extension and Harmony Road and Fairway Lane and College Avenue.
The traffic signal at Harmony Road and Fairway Lane is expected to be
installed with the construction of the South Transit Center; the Mason
Street Extension and Harmony Road signal will be installed with the
overall Mason Street Corridor project.
ii. Access and Parking Lot Requirements
a. In accordance with this section pedestrians and vehicles are separated to
the maximum extent feasible, as discussed previously with designated
walkways and colored pavement where walkways cross drive aisles.
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 7
is 5,512 square feet, which means a minimum of 37 canopy shade trees
shall be provided. The PDP is providing 37 canopy shade trees meeting
this standard.
c. All "landscape islands shall include one or more canopy shade trees, be of
length greater than eight feet in its smallest dimension, include at least 80
square feet of ground area per tree... and have raised concrete curbs."
The PDP's landscape islands are in compliance with this standard, with
the exception of 3 islands that are hindered by utility easements or parking
lot lighting required for safety purposes.
d. "Connecting walkways through parking lots... shall have one canopy
shade tree per 40 lineal feet of such walkway planted within 5 feet of such
walkway." There are two walkways in this PDP that this standard applies
to and both have trees meeting this standard.
e. "Parking bays shall extend no more than 15 parking spaces without an
intervening tree, landscape island or landscape peninsula." The PDP is in
compliance with this standard.
vii. Screening
a. Low visual interest or visually intrusive site elements, such as trash
enclosures, shall be shall be screened by landscaping or building
elements. The PDP is in, compliance with this standard, the trash
enclosure has a concrete wall surrounding it with landscape islands on
two sides.
viii. Tree Protection and Replacement
a. A Tree Mitigation Plan was submitted and reviewed against this section by
the City Forester. The site is very dense with trees currently and it has
been determined that 98 mitigation trees are required. Thirty-seven (37)
trees are planned to be transplanted onto the site, which is a value of 56
mitigation trees (per the City Forester). The remaining 42 mitigation trees
will be accomplished through upsizing trees on the site.
ix. Utilities and Traffic
a. Shade trees shall be planted at least 40' from street lights and ornamental
trees shall be at least 15' from street lights. There are no street lights
provided in this PDP, as there are no streets. There are several parking
lot lights and trees are separated from them adequately.
b. Utility easements are spaced according to the standards of this section.
B. Section 3.2.2 — Access, Circulation and Parking
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 6
iv. Landscape Area Treatment
a. This section requires landscape areas only consist of landscaping.
The selection and location of tun`, ground cover, and pedestrian paving
and other landscaping elements shall be used to prevent erosion and
meet the functional and visual purposes such as defining spaces,
accommodating and directing circulation patterns, managing visibility,
attracting attention to building entrances and other focal points, and
visually integrating buildings with the landscape area and with each
other (Section 3.2.1(E)(2), LUC).
The PDP provides appropriate landscaping to meet the standards of this
section. All areas not covered by buildings and paving surfaces are
covered with landscaping. This landscaping includes: low-water seed mix
grasses in low -use areas; planting beds with cobble mulch ground cover;
foundation plantings over approximately 56% of the high visibility areas of
the structure; and irrigated turf grass in high use areas.
Staff has determined that the landscape treatment is in accordance with
the standards of this section.
v. Parking Lot Perimeter Landscaping
a. This section requires trees be provided at a ratio of 1 per 40 lineal feet
along a side lot line. The PDP has 13 trees (1 tree per 3T) along the east
parking lot perimeter, meeting this standard.
-b. Parking lots with more than 6 spaces shall be screened from abutting
uses. "Screening from all nonresidential uses shall consist of a wall,
fence, planter, earthen berm, plant material or a combination of such
elements, each of which shall have a minimum height of 30 inches." The
PDP provides the appropriate screening to meet this standard, see the
East Landscape Section provided on Sheet 2 of 2 of the Landscape Plan
set.
vi. Parking Lot Interior Landscaping
a. According to this Section and Section 3.2.2(M)(1), parking lots with more
than 100 spaces shall have at least 10% of the interior space of the
parking lot be landscaped areas. The parking lot is 55,124 square feet
and 8,572 square feet (15%) is proposed as landscaped areas internal to
the parking lot, exceeding the minimum requirement.
b. One canopy shade tree shall be provided per 150 square feet of
landscaped area required. The minimum landscape area required (10%)
i
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 5
residence is 550+ feet away from this site. The railroad property also has
trees on it and is elevated approximately 12' from the average South
Transit Center site elevation (see attached topography map). Staff has
determined that the proposed use is incompatible with the surrounding
uses but residents at the neighborhood meeting expressed concern about
buffering being needed along the west property line. Section 3.2.1(E)(1)
requires plans that have potentially incompatible uses use one of the
following forms of landscaping to mitigate conflicts:
(a) Separation and screening with plant material: planting dense
stands of evergreen trees, canopy shade trees, ornamental trees or
shrubs;
(b) Integration with plantings: incorporating trees, vines, planters or
other plantings into the architectural theme of buildings and their
outdoor spaces to subdue differences in architecture and bulk and
avoid harsh edges;
(c) Establishing privacy: establishing vertical landscape elements to
screen views into or between windows and defined outdoor spaces
where privacy is important, such as where larger buildings are
proposed next to side or rear yards of smaller buildings;
(d) Visual integration of fences or walls: providing plant material in
conjunction with a screen panel, arbor, garden wall, privacy fence or
security fence to avoid the visual effect created by unattractive
screening or security fences;
(e) Landform shaping: utilizing berming or other grade changes to alter
views, subdue sound, change the sense of proximity and channel
pedestrian movement.
The plan uses the landscape buffering techniques described in
3.2.1(E)(1)(a). The buffering is located along the west property line to .
screen the potential impacts the rapid transit buses could have on the
residences to the west. This landscaping includes a 7' landscape strip
across approximately 75% of the west property line that includes informal
groupings of canopy shade trees, ornamental grasses and vines growing
on the existing fence; and a 5' landscape strip between the Mason
Corridor Trail and the bus travel lane that includes various shrubs for
screening. These two landscaping strips extend the entire length of the
South Transit Center structure and bus drive aisles, with the exception of
the connection to the Mason Street Extension located on the northwest
end of the site.
Staff has determined that this buffering meets the standards of this
section.
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 4
a. "Full Tree Stocking" requires:
all landscape areas within 50' of any building or structure ... be
provided in adequate numbers, location and dimensions to allow full
tree stocking to occur along all high use or high visibility sides of any
building or structure. Such landscape areas shall extend at least
seven feet from any building or structure wall and contain at least 55
square feet of non -paved ground area, except that any planting cutouts
in walkways shall contain at least 16 square feet.
Full tree stocking shall mean formal or informal groupings of trees...
Canopy shade trees shall constitute at least 50% of all tree plantings.
Landscape planters are provided along approximately 56% of the highly
visible faces of the South Transit Center building. The planting areas
range from 2' to 12' in width along the face of the structure and have
greater than 55 square feet of planting area; with the exception of one
planter, which would not be required by this standard, as adequate
planting beds are provided without it, therefore the minimum size shall not
apply to this single, approximately 40 square foot, planter.
A "full tree stocking" is provided in many locations which include: planters
internal to the platform area, tree plantings along the west side of the
Mason Corridor Trail, trees in the detention area south of the structure,
trees on the north end of the site and trees within and along the perimeter
of the parking lot. At least 50% of the trees provided will be canopy shade
trees as noted on the Landscape Plan, see Note #4.
The PDP is in compliance with the standards of this section
ii. Street Trees
a. This section requires street trees be provided in the adjoining right-of-way
in connection with the development. There are no streets included in this
PDP. All vehicle use areas are private drives, either internal to the parking
lot or internal to the South Transit Center facility. The southeast end of
the site is the only location that connects to a public street, Fossil
Boulevard; canopy shade trees are provided meeting the standards of this
section from Fossil Boulevard to the entrance of the parking lot and transit
facility.
iii. Buffering between Incompatible Uses and Activities
a. This section of the Code requires buffering techniques be used to mitigate
conflicts between incompatible uses. The railroad track's 190' wide
property separates this site from residential uses to the west; the closest
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 3
S: C; Existing warehouses
E: C; Vacant
W: UE, Urban Estate; Existing single family development
The property was annexed into the Arbor South First Annexation in March of 2001. It
has remained unplatted since that time. The site is currently unimproved; a small on the
south end has a gravel parking lot for users of the Mason Corridor Trail.
2. Compliance with Division 4.21 C, Commercial District:
A. Permitted Uses:
"Transit facilities without repair or storage" are permitted in the C, Commercial
District subject to a Type 1 (administrative) review and public hearing.
B. Land Use Standards:
The Commercial district limits building height to four (4) stories. The PDP is
proposing a 27''/z" structure, story height is defined to be 12' 8" in Section
3.8.17(2)(c), therefore the structure is meets the standard set forth in this section.
C. Development Standards:
Section 4.21(E)(2) Site Design states that:
Pedestrian -oriented outdoor spaces shall be placed next to activity areas that
generate the user. Because liveliness created by the presence of people is
the main key to the attractiveness of such spaces, to the maximum extent
feasible, the development shall link outdoor spaces to and make them visible
from streets and sidewalk. Sculpture, kiosks or shelters are encouraged to be
prominently placed in outdoor spaces.
The proposed structure and user waiting area is centrally located to
accommodate the primary use of this site, which is transit ridership. The covered
bus bays have benches and information kiosks creating gathering spaces for
riders in appropriate locations to serve the use of the site, which are visible from
and linked to the public sidewalk spurring off of Fossil Boulevard and the Mason
Corridor Trail
3. Compliance with Applicable General Development Standards:
The PDP complies with the applicable General Development standards as follows:
A. Section 3.2.1— Landscaping and Tree Protection
i. Minimum Plantings
South Transit Center — Project Development Plan, #9-10
November 15, 2010 Administrative Hearing
Page 2
RECOMMENDATION:
• Approval of the Modification of Standard Requests to:
o Section 3.5.3(8)(1) Orientation to a Connecting Walkway, and
o Section 3.5.3(B)(2) Orientation to Build -to Lines for Street Front Buildings
• Approval of the Alternative Compliance Request to:
o Section 3.2.2(K)(2) for Nonresidential Parking Requirements
• Approval of the South Transit Center, PDP #9-10
EXECUTIVE SUMMARY:
• Transit facilities without repair or storage are permitted in the (C) Commercial
District, subject to an administrative review.
• The South Transit Center, PDP complies with the applicable General
Development Standards of Article 3, with the exception of:
- Two Modification of Standard Requests:
1. Section 3.5.3(B)(1) Orientation to a Connecting Walkway, and
2. Section 3.5.3(B)(2) Orientation to Build -to Lines for Street Front
Buildings
- One Alternative Compliance Requests:
1. Section 3.2.2(K)(2) for Nonresidential Parking Requirements
• The South Transit Center, PDP complies with the land use and development,
standards of the Division 4.21 C, Commercial District.
COMMENTS:
1. Background:
The surrounding zoning and land uses are as follows:
N: C, Commercial; Existing Spradley Barr Dealership
Fort Collins
�f�
PROJECT: South Transit Center, PDP, #9-10
APPLICANT: Jerod Huwa
BHA Design, Inc
1603 Oakridge Drive
Fort Collins, CO, 80525
OWNER: City of Fort Collins - Transfort
250 N Mason Street
Fort Collins, CO 80524
PROJECT DESCRIPTION:
lit NO 6 1
MEETING DATE (( D
STAFF it! �(,}-eOL(k
HEARING OFFICER
This is a request for a "transit facility without repair or storage," known as the South
Transit Center, PDP, to be located southwest of South College Avenue and Harmony
Road, just south of the Spradley Barr dealership (northwest of West Fairway Lane and
Fossil Boulevard). The proposed development is on approximately 4.3 acres, directly
adjacent to the BNSF Railroad and the Mason Corridor Trail. The site is in the
Commercial (C) Zone District.
The site would be the south terminus of the Mason Corridor. Mason Street is proposed
to extend to the site, from the north, along the railroad tracks. The Mason Street
Extension will only be used by the rapid transit buses; users will access the site via
Fossil Boulevard or pedestrians can access the site via the existing Mason Corridor
Trail that runs adjacent to the railroad tracks.
The proposal includes a 169 space "park-n-ride" lot, 11 bus bays and a 4,253 square
foot building. A north/south drive is provided along the east side of the site, as
designated by the South College Access Control Plan. It will serve to give the sites to
the east and north access to Fairway Lane and College Avenue, the future location of a
traffic signal.
The proposal includes two modification of standard requests; one to the 'orientation to
connecting walkway" standard, which requires the front of a building open directly onto
a connecting walkway with pedestrian frontage that does not pass a vehicle use area;
and the second is to the "build -to" line standard, which requires structures be located
within 15 feet of the adioinina street riaht-of-way.
' Current Planning 281 N College Av PO Box 580 Fort Collins, CO 80522-0580
fcgov.com/currentplanning 970.221.6750