HomeMy WebLinkAbout224 WOOD ST. - ACCESSIBLE BUILDING W/HABITABLE SPACE - PDP/FDP - 8-10/A - CORRESPONDENCE - (3)[4/27/10] Please provide a grading plan for the rear third of the lot per conceptual review comments. The distance to the south lot line is very minimal. The drainage of this new structure can not have a negative impact to the property and structure to the south. A concrete pan may be needed to direct the water to the alley or to the front. {Drainage will be addressed with gutters and spouts per plan.} Number: 6 Created: 4/27/2010 [4/27/10] Please direct the down spouts to grassy surfaces for water quality treatment. {Acknowledged} Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 7 Created: 4/27/2010 [4/27/10] The water and sewer services for the house connect to water and sewer mains in Wood Street. There are no water/sewer mains in the alley. /Acknowledged} Department: Zoning Issue Contact: Gary Lopez Topic: Zoning Number: 1 Created: 4/21 /2010 [4/21/10] There is not enough information to conclude this bldg. is 1.5 stories. Interior elevation drawings and floor plans are required. Per LUC 5.1 Def. Story, half "shall mean a space under a sloping roof which as the line of intersection of the roof and wall face not more than three (3) feet above the floor level, and in which space the possible floor area with head room of five (5) feet or less occupies at least forty (40) percent of the total floor area of the story directly beneath." {Acknowledged} Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Emma McArdle City Planner Page 4 If the structure will ever be used as a sleeping area (Residential Occupancy Type), the following requirements must be met: WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. PLEASE NOTE: In response, to Bryan Soth's question, I don't have flow records for that area but Roger Buffington from FC Water might. The closest hydrant is at 240 Wood St. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: ❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ❑ Have appropriate maintenance agreements that are legally binding and enforceable. ❑ Be designated on the plat as an Emergency Access Easement. ❑ Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structures is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. PLEASE NOTE: The proposed structure is approximately 165 feet from the edge of Wood Street. Also, PFA does not "count" alleys as a means of emergency vehicle access. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). 2006 International Fire Code 505.1 (Acknowledged) Department: Technical Services Topic: General Number: 2 [4/22/10] We have no comments. Department: Stormwater-Water-Wastewater Topic: Stormwater Number: 5 Issue Contact: Jeff County Created: 4/22/2010 Issue Contact: Wes Lamarque Created: 4/27/2010 Page 3 This structure is considered an "accessory structure with habitable space," it is not a dwelling unit and may not be used as a dwelling unit in the future without further review by the City and Poudre Fire Authority. If the structure is used for sleeping quarters by a resident of the primary structure, which is considered "residential occupancy" by Poudre Fire Authority, the structure will need to meet the specified requirements of Poudre Fire Authority regarding emergency vehicle access, firefighting water supply and structure addressing. {Acknowledged} Department: Engineering Issue Contact: Susan Joy Topic: Engineering Number: 8 Created: 4/27/2010 [4/27/10] Please submit a Utility Plan set in accordance with LCUASS. fAcknowledged} Number: 9 Created: 4/27/2010 [4/27/10] Please submit a completed checklist from Appendix E4 with the next submittal and include all required items on your plan sets. (Acknowledged} Number: 10 Created: 4/27/2010 [4/27/10] The driveway off the alley must be paved. {Owner would prefer a concrete apron and gravel driveway for drainage but is OK with concrete driveway if required.} Number: 11 Created: 4/27/2010 [4/27/101 Show all utilities on the landscape plan. (Acknowledged) Number: 12 Created: 4/27/2010 [4/27/10] All easements must be labeled with what type it is and if it is proposed or existing. For example: Existing 9' Utility Easement or Proposed 9' Utility Easement. {Acknowledged} Number: 13 Created: 4/27/2010 [4/27/10] Please see LCUASS for all of the required information that must be shown on the utility plan set and coordinate the utility, site and landscape plans. {Acknowledged} Department: Light & Power Issue Contact: Janet McTague Topic: General Number: 4 Created: 4/27/2010 [4/27/10] If the transformer needs to be relocated ( it looks like it was placed outside of the easement), this will be done at L&P expense. If service is taken from the house, we have no further comments. If additional power is needed, service will come from the existing transformer and normal fees will apply. (Power will come from house. Transformer does not need to be relocated.) Department: PFA Topic: Fire Authority Number: 3 Issue Contact: Carie Dann Created: 4/26/2010 Page 2 9) of �;F6rt Collins BRYAN SOTH HIGHCRAFT BUILDERS 429 S. HOWES ST FORT COLLINS, CO 80521 STAFF PROJECT REVIEW Date: 4/28/2010 Staff has reviewed your submittal for 224 WOOD STREET - ACCESSORY BUILDING WITH HABITABLE SPACE PDP - TYPE I, and we offer the following comments: ISSUES: Department: Advance Planning Issue Contact: Emma McArdle Topic: Modification of Standards Number: 14 Created: 4/28/2010 [4/28/10] The modification of standards request needs to identify which criteria the request is meeting in 2.8.2 of the LUC, there are 4 criteria, please site the once you are using, it would most likely be the criteria describing hardship. {The modification is requested for reasons of "exceptional physical conditions or other extraordinary and exceptional situations... "} Topic: Site Plan Number: 15 Created: 4/28/2010 [4/28/10] Please add standard signature blocks to the site plan, I can give you an example of what these look like and say. (Acknowledged) Number: 16 Created: 4/28/2010 [4/28/10] Please start off with Title on top - "224 Wood Street - Accessory Building with Habitable Space," the legal description should follow below. {Acknowledged? Number: 17 Created: 4/28/2010 [4/28/101 Please add/change the following on the Site Plan: - change scale to engineer's scale, - show height of building, - add 1/2 lot line for FAR reference, - show full ROW and dimensions (including separated out sidewalk, parkway, curbline), - add existing and proposed utility lines (water, sewer, electric), - clarify easements, - proposed impervious surface in s.f. - change SYSB to spell out Side Yard Setback, FYSB, etc., - change gravel to paved surface used, - add lines of neighboring property lines to show some context, - are there existing trees in the parkway? If so please show them. {Acknowledged} Number: 18 Created: 4/28/2010 [4/28/10] Please add the following notes to the site plan: Page 1