HomeMy WebLinkAboutMISTER MONEY (2057 VERMONT DR.) WTF - PDP - 31-08 - CORRESPONDENCE -Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 8 Created: 9/24/2008 [9/24/08] As long as it is not an enclosed structure attached to the existing building, and as long as it does not obstruct access to fixed -fire protection, PFA has no comments or concerns. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: WaterMastewater Number: 3 Created: 9/22/2008 [9/22/08] Have the water main extending south from Vermont located and surveyed to show location accurately on the site plan. Comments from Current Planning: Be sure to provide the letter that in the event of structural failure, the pole will collapse upon itself and not topple over at its full height. 2. Please provide a shrub bed along the north and east sides of the enclosure. The species, size and quantity of the shrubs should be provided in a Plant Schedule. 3. There is a tree that has been chopped down along the east property line. This tree needs to be replaced. The replacement tree must be no less than 2.5 inches in caliper. This tree must also be noted in the Plant Schedule. 4. Be sure to indicate how the new plant material will be irrigated. 5. Please indicate the setback of the enclosure from the north property line. 6. Please note that there will no exterior lighting associated with this facility. This concludes our comments at this time. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221- 6750. Sincerely: Ted Shepard Chief Planner Page 2 6i STAFF PROJECT REVIEW City of Fort Collins Steve Warner Date: 9/26/2008 Reliant Land Services, Inc. 7901 E. Lowry Blvd, Suite 300 Denver, CO 80230 Staff has reviewed your submittal for MISTER MONEY - T-MOBILE WIRELESS TELECOMMUNICATION FACILITY PDP - TYPE I, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Dana Leavitt Topic: General Number: 4 Created: 9/23/2008 [9/23/08] Provide context map or aerial photograph for surrounding area. This site appears to be within 500 feet of potential natural habitats and/or areas as defined in Section 3.4.1 of the Land use Code. Department: Engineering Issue Contact: Andrew Carney Topic: General Number: 5 Created: 9/23/2008 [9/23/08] The tower does not appear to meet the setback requirements in section 3.8.13 C1. If it can be demonstrated that the tower will collapse rather than topple, the setback requirement can be waived. Number: 6 Created: 9/23/2008 [9/23/08] The proposed block wall is listed as 6' on the title page and Ton the site plan, please edit the site plan note. The maximum allowed fencing shall not exceed 6' (3.8.13 C5). Number: 7 Created: 9/23/2008 [9/23/08] Please change the scale on sheet Z1 to match the scale of the page Department: Light & Power Issue Contact: Alan Rutz Topic: Fire Number: 9 Created: 9/26/2008 [9/26/08] Submit a Commercial C-1 form with load and voltage requirements. Number: 10 Created: 9/26/2008 [9/26/08] There is an existing three phase transformer at the site. Number: 11 Created: 9/26/2008 [9/26/08] The electric meter must be placed on the outside of the enclosure. Number: 12 Created: 9/26/2008 [9/26/08] Locate the existing electric primary line on the site and show it on your site plan. The enclosure can not be placed over the primary line. Page 1