HomeMy WebLinkAboutOTTER BOX DISTRIBUTION/WAREHOUSE EXPANSION - FDP - 17-10/A - CORRESPONDENCE --[9/7/10] Please bury all riprap located within the floodway and provide temporary erosion control until vegetation is established. NE Response: The drawings have been updated. Number: 50 Created: 9/7/2010 (9/7/10] Please label elevation of first WQ hole on the riser pipe. NE Response: The detail has been updated. Number. 51 Created: 9/7/2010 [9/7/10] Please see other minor comments on the redlined plans. NE Response: The redlines have been addressed. Number: 52 Created: 9/7/2010 [9/7/10] Please see the 100% Floodplain Checklist and the redlined plans and report for all floodplain comments. NE Response: The redlines and Checklist comments have been addressed. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. SinTcerely: �� /A"y�, 1 Ted Shepard Chief Planner Page 3 Fire access roads (fire lanes) shall be provided for every building constructed within the PFA's jurisdiction when any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. Any new fire lane must meet the following general requirements: ❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. ❑ Have appropriate maintenance agreements that are legally binding and enforceable. ❑ Be designated on the plat as an Emergency Access Easement. ❑ Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D Number. 35 Created: 7/28/2010 [9/7/10] The "proposed No Parking signs" shown on Sheet C200 should actually be "proposed FIRE LANE - NO PARKING" signs as shown on Sheet C601. NO PARKING SIGNS: Thank you for showing the "NO PARKING" signs. Please change them to NO PARKING FIRE LANE; I'd be happy to provide you with a sign template. NE Response: The notes on Sheet C200 have been corrected. Number. 36 Created: 7/28/2010 [9/7/10] Knox Boxes should be mounted approximately 60 inches above grade but no higher than 72 inches above grade. KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or fire -alarm system. PLEASE NOTE: If only one Knox Box is currently in place, an additional Knox Box must be installed. Knox Boxes are available at cost from the PFA Fire Prevention Bureau. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 VFR Response: The proposed Knox Box will be located between 60"-72" above grade. Number: 39 Created: 7/28/2010 [9/7/10] Were you able to correct C7 and C11 so they meet requirements? TURNING RADII The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 5�3.2 4 and Appendix D103 3 NE Response: A variance has been approve by t e City an PFA regarding these two existing radii. Department: Technical Services Issue Contact: Jeff County Topic: Plat Number: [9/3/10] The plat boundary closes. V123110] The Plat boundary closes. Department: Stormwater-Water-Wastewater Topic: Stormwater Number: 49 Created: 7/23/2010 Issue Contact: Wes Lamarque Created: 9/7/2010 Page 2 Linda Ripley Ripley Design, Inc. 401 W. Mountain Ave. Fort Collins, CO 80521 STAFF PROJECT REVIEW Date: 9/9/2010 Staff has reviewed your submittal for OTTER BOX DISTRIBUTIONNVAREHOUSE EXPANSION PDP & ADDITION OF A PERMITTED USE - TYPE II & FINAL PLANS, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Andrew Carney Topic: General Number: 45 Created: 9/2/2010 [9/2110] Along with this round of review I am providing the Information sheets for both the Development Agreement as well as the Development Construction Permit. As the project moves forward we can certainly begin work on both items. NE' Response : Both the information sheet and the DCP application have been submitted. Topic: Plat Number. 17 Created: 7/27/2010 [9/2/10] Carried forward as a reminder. Please contact me for the dedication templates. Each dedication is subject to a $250 TDR Fee as well as recording fees for recording the document with Larimer County.NE Response: The one off site easement that would require a separate dedication statement has been removed from the project. Topic: Utility Plan Number: 47 Created: 9/7/2010 [9/7/10] Detail 709 was included with the set. If chases are needed, please use detail D12B for a concrete chase with a detached walk. NE Response: Detail 709 has been replaced with Detail D-10. Number. 48 Created: 9/7/2010 [9/7/10] Please add Detail 1606. NE Response: Detail 1606 has been added. Department: Light & Power Issue Contact: Doug Martine Topic; Light and Power Number: 44 Created: 9/1/2010 [9/1/10] In order to complete the final electric utility plans, Light & Power Engineering will need a copy of the recorded replat AND a copy of the original plat showing original lots 9, 10, and 11. If any questions, please contact Doug Martine at (970)224-6152. NE Response: Both plats will be copied to Doug Martine once the Replat has Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 28 Created: 7/28/2010 [917/10] The "proposed No Parking signs" shown on Sheet C200 should actually be "proposed FIRE LANE - NO PARKING' signs as shown on Sheet C601. EMERGENCY VEHICLE ACCESS NE Response: The notes on sheet C200 have been Thank you for showing the Emergency Access Easement. Please make the east boundary (dotted line) easier to differentiate as the EAE on the plat. Also, please correct EASEMET on page S-2 of the site plan. REQUIRED ACCESS been recorded. corrected. Page 1