HomeMy WebLinkAboutPENNY FLATS SUBDIVISION, FIRST REPLAT - PDP & FDP - 21-10 - CORRESPONDENCE - (3)Fart` J oll�s 1. Verify there are no electric lines that cross the proposed property lines. If there are easements would be required. CURRENT PLANNING Contact: Courtney Rippy, 970-416-2883, crippy(a(7fcgov.com Must comply with 3.3.1. of LUC 2. The proposed development is subject to a Basic Development Review. please contact the Zoning Department regarding your formal submittal. Page 4 of 4 1. EMERGENCY VEHICLE ACCESS: The same requirements for Emergency Access Easement still apply (below). Also, the plat note about overhead balcony and bridge encroachments into the EAE, still apply. This note must be carried to the new plat. Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: - Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. - Have appropriate maintenance agreements that are legally binding and enforceable. - Be designated on the plat as an Emergency Access Easement. - Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structures is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D ENVIRONMENTAL PLANNING Contact: Erica Saunders, 970-416-2032, esaunders(a)fcgov.com 1. No comments. ENGINEERING DEVELOPMENT REVIEW Contact: Marc Virata, 970-221-6567, mvirata(d).fcgov.com 1. The replat proposal would be subject to TDR Fees as attached for PDP ($2,000 + [# acres x $2501) and Final, which would appear to be $2,218.25 and $1,000 respectively. 2. If the below ground parking structure spans across the proposed lot lines, per Mike Gebo in building inspection, a cross access easement is needed between the individual lots in the replat, this can be accommodated on the plat. 3. Either an amendment to the development agreement (adding the legal description of the replat to be also part of the development agreement); or a note on the replat stating that the Penny Flats DA shall apply to the replat, is required. ELECTRIC ENGINEERING Contact: Alan Rutz, 970-224-6153, arutz(afcgov.com Page 3 of 4 E Fc o CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: May 17, 2010 Item: Penny Flats - Replat Applicant: John Koval 3020 Carbon Place # 203 Boulder, CO 80302 jkoval@coburndev.com Land Use Data: This is a request to replat lot 1 of Penny Flats to create separate parcels. Comments: ZONING Contact: Jenny Nuckols, 970-416-2313, inuckols(@fcgov.com 1. No comments WATER -WASTEWATER ENGINEERING Contact: Roger Buffington, 970-221-6854, rbuffington(d4cgov.com 1. All utility easements shown on the original plat must be included in the replat. STORMWATER ENGINEERING Contact: Glen Schlueter, 970-224-6065, gschIueterrafcaov.com 1. This proposed replat doesn't appear to affect the drainage system; therefore, Stormwater has no comments. PARK PLANNING Contact: Craig Foreman, 970-221-6618, cforeman(a�fcgov.com 1. No comment FIRE AUTHORITY Contact: Carie Dann, 970-219-5337, cdannapoudre-fire.orq Page 2 of 4 n 0 City of Fart Collins May 28, 2010 John Koval 3020 Carbon Place # 203 Boulder, CO 80302 RE: Penny Flats - Replat Dear John, Community Development and Neighborhood services 261 North College Avenue PC Box 580 Fort Collins. CC 80522 970.221.6750 970.224.6134 - fax fcgov comicurrentp/annmg Attached, please see a copy of Staffs comments concerning the request referred to as the Penny Flats - Replat, which was presented before the Conceptual Review Team on May 17, 2010. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to contact me at 970-416-2883. Sincerely, Courtney Rippy City Planner 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 — (970) 221-6750 - FAX (970) 224-6134