HomeMy WebLinkAboutTHE OVAL FLATS - PDP - 26-08 - REPORTS - RECOMMENDATION/REPORTThe Oval Flats, PDP complies with the land use and development standards in Division 4.18 CC, Community Commercial District. The Oval Flats, PDP is proposed to be on a property that is included in the TOD overlay zone. RECOMMENDATION: Staff recommends approval of Oval Flats, Project Development Plan - #26-08. 13 (2) With respect to multiple -family dwellings, the decision maker (depending on the type of review, Type 1 or Type 2) may, upon receipt of a written request from the applicant and upon a finding that all applicable criteria of this Land Use Code have been satisfied, increase the number of unrelated persons who may reside in individual dwelling units. The decision maker shall not increase said number unless satisfied that that the applicant has provided such additional open space, recreational areas, parking areas and public facilities as are necessary to adequately serve the occupants of the development and to protect the adjacent neighborhood. Applicant's Request: BECAUSE THE PROPOSED PROJECT IS FOCUSED ON HOUSING CSU STUDENTS, PER SECTION 3.8.16(E) OF THE LAND USE CODE, THE APPLICANT HEREBY REQUESTS A MODIFICATION SUCH THAT THE PROVISIONS OF THE LAND USE CODE RESTRICTING THE NUMBER OF UNRELATED PARTIES BE WAIVED. Staff recommends that that the Hearing Officer grant the request for an increase in the number of unrelated persons who may reside in individual dwelling units from the allowable 3 persons to 4 persons for the three 4-bedroom dwelling units only. 5. Neighborhood Compatibility: A neighborhood meeting was held on August 5, 2008. Notes recorded at this meeting are attached. Most of the questions centered on the amount of parking to be provided on -site, how the applicant will control potential rowdy behavior, lighting and safety, vehicle access points to the site, and storm water issues. 6. Findings of Fact/Conclusion: In reviewing the request for the Oval Flats, PDP, Staff makes the following findings of fact: Mixed -Use Dwellings are permitted in the CC, Community Commercial District, subject to administrative review. The Oval Flats, PDP complies with applicable General Development Standards of Article 3. 12 The Oval Flats, PDP complies with the building character and image requirements set forth in Section 3.5.3(D) Character and Image as they relate to facade treatment, entrances, awnings, and base & top treatments. G. Section 3.6.4 — Transportation Level of Service Requirements The Transportation Impact Study that was submitted as part of the Oval Flats, PDP has been reviewed by City staff. First, the project represents infill re- development. Second, the project replaces a facility that generated a significant number of trips. The trip generation was discussed and agreed to in a scoping meeting between the Applicant and City staff. There will be no direct vehicular access on to West Laurel Street or South Howes Street. The parking lot is located behind the building and will gain access only from the alley along the west side of the property. The site is within walking distance to the Colorado State University Transit Center. H. Section 3.8.16 — Occupancy Limits; Increasing the Number of Persons Allowed Section 3.8.16(A) specifies: (A) Except as provided in subsection (B) below, or pursuant to a certificate of occupancy issued by the city to the owner of the property, the maximum occupancy allowed per dwelling unit in a single-family, two-family or multi- family dwelling shall be: (1) one (1) family as defined in Section 5.1.2 and not more than one (1) additional person; or (2) two (2) adults and their dependents, if any, and not more than one (1) additional person. Section 3.8.16(E) of the LUC allows an owner to petition the appropriate decision maker for an increase in the number of unrelated parties allowed within an individual unit by: (E) Increasing the Occupancy Limit. (1) With respect to single-family and two-family dwellings, the number of persons allowed under this Section may be increase by the issuance of a certificate of occupancy for use as an extra occupancy rental house in zones allowing such use. 11 The Oval Flats, PDP complies with the standard set forth in Section 3.5.3(B)(2)(b) as it relates to the "build -to" line setback from South Howes Street. The building will, be set back 0' to 5' from the right-of-way (ROW) line for the street, being a 2-lane arterial street, which is smaller than a full arterial. Therefore, it satisfies the requirement that the building shall be located no more than 15' from the ROW for South Howes Street. The Oval Flats, PDP does not comply with the standard set forth in Section 3.5.3(B)(2)(c) that states: "Buildings shall be located at least ten (10) and no more than twenty-five (25) feet behind the street right-of-way of an adjoining street that is larger than a two-lane arterial that does not have on -street parking." The building is proposed to be located right on the ROW line for West Laurel Street, a 4-lane arterial that does not have on -street parking. There are, however, exceptions to the build -to line standards that the Director can grant, as set forth in Section 3.5.3(B)(2)(d). They are: 1. "In order to form an outdoor space such as a plaza, courtyard, patio or garden between a building and sidewalk. Such a larger front yard shall have landscaping, low walls, fencing or railings, a tree canopy and/or other similar site improvements along the sidewalk designed for pedestrian interest, comfort and visual continuity." 2. "if the building abuts a four -lane or six -lane arterial street, and the Director has determined that an alternative to the street sidewalk better serves the purpose of connecting commercial destinations due to one (1) or more of the following constraints: a. high volume and/or speed of traffic on the abutting street(s), b. landform, C. an established pattern of existing buildings that makes a pedestrian -oriented streetfront infeasible." The PDP contains commercial/retail and multi -purpose spaces on the ground floor facing West Laurel Street that will abut and gain direct pedestrian access from an 8' wide detached sidewalk along the street, which is a 4-lane arterial that carries a high volume of traffic. This satisfies the exception criterion set forth in Section 3.5.3(B)(2)(d)2.a. 10 Based on the Oval Flats Shadow Study Narrative and Shadow Studies Graphic provided by the Applicant, it appears that the 54' tall building in the project will have minimal impacts on surrounding properties. There will be a shadow cast on a portion of the 3 plex residential building to the west, across the alley, for a short period of time in the early morning and there will be a shadow cast on the church building to the north for a short period of time around the noon hour during several of the winter months. 3. Privacy. Buildings or structures greater than 40' in height shall be designed to avoid infringing on the privacy of adjacent public and private property, particularly adjacent residential areas and public parks. The 54' tall building in the Oval Flats, PDP is located and oriented on the site such as to minimize privacy infringement on surrounding properties containing residential uses. There are no public parks in this area. On the east side there is a 2-lane arterial street between this project and several residences, with a distance of approximately 100' building to building. To the north is an existing church. To the south is West Laurel Street, a 4-lane arterial, between this project and Colorado State University. To the west, across the alley, is an existing 3-plex, 2-story residential building (Laurel Street Lofts). The distance between the west end of the Oval Flats building, containing only a few dwelling units at this end, and the residential building across the alley is approximately 32'. 4. Neighborhood Scale. Buildings or structures greater than 40' in height shall be compatible with the scale of the neighborhoods in which they are situated in terms of relative height, height to mass, length to mass, and building or structure scale to human scale. The Oval Flats, PDP contains a 4-story building that is relative in height, height to mass, and length to mass to several existing buildings in the surrounding neighborhoods and on the Colorado State University campus (examples: CSURF building, Laurel Street Lofts, Atrium Suites, Guggenheim Hall). F. Section 3.5.3 — Mixed -Use, Institutional and Commercial Buildings 0 years to come. It is our belief that a new facility should not mimic architectural elements which may not be relevant in the near future. In summary, we feel the proposed building design is setting an enhanced standard of quality for future projects or redevelopment in the area because the existing architectural character is not definitively established, or is not consistent with the purposes of the Land Use Codes. In this proposed design we have achieved compatibility through use of repetitive roof lines, similar window patterns and use, and color and texture of building materials similar to those existing in the immediate area of the proposed infill. It is our intent to not compete with these existing styles based upon old technologies and obsolete design elements, but to create a design that can support itself on its own merits. E. Section 3.5.1(G) — Building Height Review The purpose of this section is.to establish a special process to review buildings or structures that exceed 40' in height. If any building or structure is proposed to be greater than 40' in height above grade, the building or structure must meet the following special review criteria: 1. Views. A building or structure shall not substantially alter the opportunity for, and quality of, desirable views from the public places, streets and parks within the community. Desirable views are views by the community of the foothills, mountains and/or significant local landmarks. The 54' tall building in the Oval Flats, PDP is located in a dense urban setting that contains very mature trees and several existing tall buildings. It will not obstruct views of the foothills and mountains to the west any more than the existing features already do. 2. Light and Shadow. Buildings or structures greater than 40' in height shall be designed so as not to have a substantial adverse impact on the distribution of natural and artificial light on adjacent public and private property. Adverse impacts include, but are not limited to, casting shadows on adjacent property sufficient to preclude the functional use of solar energy technology, creating glare such as reflecting sunlight or artificial lighting at night, contributing to the accumulation of snow and ice during the winter on adjacent property, and shading of windows or gardens for more than 3 months of the year. P. Design Compatibility Regarding Building and Project Compatibility in Section 3.5.1 of the Land Use Code and Mixed -Use Institutional and Commercial Buildings in Section 3.5.3, we propose the following: Building design will utilize traditional blond and red brick at the main level and corner element. These materials were selected based upon site surrounding palette of materials taken buildings such as the CSU Guggenheim and Industrial Sciences building across the street and the residential character of the neighborhood. To enhance the pedestrian experience, the main level on both the Howes and Laurel streetscapes will also have sunscreen awnings, brick accent detailing, a strong repetitive fenestration, and a clearly defined brick cornice element at the top of the parapet where the upper three levels of the building then step back. The residential units above will be a mixture of true cement stucco and 5" exposure horizontal lap siding to reflect materials and textures used in the surrounding residential structures. These materials are also broken up by the use of color on corresponding massing elements. The corner of the building has been pulled into the building to create a plaza and open the view corridor from Howes Street facing south. The use of the proposed slightly sloping roof forms serves to fulfill the client's desire to have a modern yet timeless upscale mixed use building to attract both residential and commercial tenants. The vertical facade masses are articulated with strong base elements, a repetition of horizontal planes on top contrasted by larger planes with corniced parapets. The corner element of the building uses a blond brick to tie in the campus building across the street, flanked by massive vertical planes that echo the large stone plane utilized across the street at the Danforth Chapel. While gabled roof forms were encouraged by City staff at the first PDP submittal, the design team explored options for this treatment to the top of the building. The team felt that that gable roof forms felt forced, and made the project look more like a hotel chain rather than an upscale mixed -use building, while also increasing the overall height of the building. It has also been discussed that because of the TOD Overlay Zone/Mason Street Corridor area, it is likely that some other adjacent properties surrounding the site will be redeveloped in 7 The property is located in the City's defined Transit -Oriented Development Overlay Zone. Section 3.2.2(K)(1)(a)1 states: "Multi -family dwellings and mixed -use dwellings within the Transit - Oriented Development (TOD) Overlay Zone shall have no minimum parking requirements." Since the Oval Flats, PDP contains only a mixed -use dwelling as the proposed land use, there are no minimum on -site parking requirements associated with the project. However, the applicant is proposing an on -site surface parking lot behind the building, with access from the alley along the west side, that contains 58 parking spaces (compact, long-term, handicap). For reference only, and based on the minimum parking requirements for the mix of 1-, 2-, 3-, and 4-bedroom dwelling units, a total of 89 parking spaces would be required if the project were not in the TOD Overlay Zone. D. Section 3.5.1— Building and Project Compatibility The building is 4 stories (54'-1 ") in height. The first floor contains residential dwelling units, retail space, and multi -purpose space. The upper three floors contain the balance of the dwelling units. How the building satisfies the criteria set forth in Section 3.5.1(13) Architectural Character, Section 3.5.1(C) Building Size, Height, Bulk, Mass, Scale, Section 3.5.1(E) Building Materials, and Section 3.5.1(F) Building Color is described in the Applicant's Design Narrative (below). Applicant's Oval Flats Design Narrative: Site Context The proposed site of this mixed -use infill building is located at the northwest corner at the intersection of Howes and Laurel Streets. The surrounding context is truly a "mixed bag" with no clear or predominate architectural character. To the west of the project, there is a 2-1/2 story bungalow style apartment building directly adjacent with 2- and 1-1/2-story residential rental properties beyond. To the north, there is a 2-story house converted to a business with an attached 1-story addition, and the large, 5-story concrete CSURF building designed in the Brutalism style beyond. Across the street to the east are 1-1/2 and 2-story residential rental properties with a mix of early 20th century styles. To the north is the main entrance to Colorado State University campus via the Oval and a mix of prominent buildings including the classical/Greek revival styled Guggenheim Hall to the southeast, the mid-century modern, Danforth Chapel directly across the street and the blond brick, Mission styled, Ammons Hall, to the southwest. The result of this surrounding context is that there is no one distinct architectural character or building typology. The PDP contributes to the standard set forth in Section 4.18(E)(2)(c) Minimum Building Frontage that requires 40% of each block side or 50% of the total of all block sides to consist of either building frontage, plazas or other functional open space. The proposed mixed -use dwelling building and pedestrian plaza front entirely on the 2 adjacent streets. The subject block is bounded by West Laurel Street to the south, South Howes Street to the east, West Myrtle Street to the north, and South Meldrum Street to the west. The PDP satisfies the standard set forth in Section 4.18(E)(2)(d) Building Height. The building is to be 4 stories in height, which is less than the limit of 5 stories. Also, the building is to be 54'-1" in height, exceeding the minimum height requirement of 20'. 4. Compliance with Applicable General Development Standards: As can be seen by the previous section, the CC zone contains numerous specific standards. Where CC District standards of Article 4 are more specific or stringent, they prevail over the less specific or stringent standard that may be found in the General Development standards of Article 3. The PDP complies with the applicable General Development standards as follows: A. Section 3.2.1— Landscaping and Tree Protection The PDP satisfies the applicable standards set forth in this section of the LUC. Existing and proposed street trees are being provided, foundation plantings will be provided in the landscape strip between the building and the detached sidewalk along South Howes Street, and the required amount of interior parking lot landscaping is being provided. Some existing trees on -site are to be removed and will be replaced with the required number of mitigation trees. B. Section 3.2.2 — Access, Circulation and Parking The site is an infill location surrounded by existing development including Colorado State University. Connections for vehicles, bikes and pedestrians are existing in the area. For example, sidewalks are existing in 2 directions to link the mixed -use dwelling structure to streets, alley, and campus. The existing sidewalk along West Laurel Street will be replaced with a new 8' wide detached sidewalk right along the front of the building. The existing sidewalk along South Howes Street will be replaced with a new 6' wide detached sidewalk. A bike rack is provided. The parcel is at the signalized intersection of West Laurel Street and South Howes Street, allowing a safe crossing of Laurel Street to C.S.U. C. Section 3.2.2(K) - Parking Lots — Required Number of Off -Street Spaces for Type of Use The Plan and zone district standards clearly envisioned a transitional and buffering function for new mixed -use development in the area between North College Avenue and the residential areas along West Laurel Street. The property is located in the area of the West Side Neighborhood Plan that falls between the identified East Buffer Area and the Campus Commercial Area. Both of these areas in the plan encourage mixed -use development/redevelopment similar to the proposed Oval Flats, PDP. Staff finds that the new mixed -use (predominantly residential) development is the appropriate land use the West side Neighborhood Plan envisioned for the Retail/Mixed-Use Redevelopment Area. 3. Compliance with Division 4.18 CC, Community Commercial District: Land Use: The land use is considered to be a mixed -use dwelling. The Oval Flats, PDP contains 48 dwelling units on the 1st 2"d 3rd and 4th floors of the building. The 1st (ground) floor also contains 4,585 square feet of commercial/retail space and 3,012 square feet for the SAE Fraternity lodge space. The land use is permitted in the CC District, subject to an Administrative review and public hearing in front of a Hearing Officer. Density: The CC District has no density/intensity requirements. Dimensional Standards: The CC District has no dimensional standards. Development Standards: The building orientation satisfies the standard set forth in Section 4.18(E)(1)(a) Building Orientation. The ground floor commercial/retail primary entrances into the building orient to West Laurel Street and South Howes Street, being pedestrian -oriented streets, not to the internal parking lot. The PDP satisfies the standard set forth in Section 4.18(E)(1)(b) Central Feature or Gathering Place. There is a significant pedestrian plaza containing movable tables at the southeast corner of the project, adjacent to the West Laurel Street — South Howes Street intersection. Prefabricated planters are located along the east and south sides of the plaza. 4 EXECUTIVE SUMMARY: * Mixed -use dwellings are permitted in the CC, Community Commercial District, subject to an administrative review. * The Oval Flats, PDP complies with applicable General Development Standards of Article 3. * The Oval Flats, PDP complies with the land use and development standards of the Division 4.18 CC, Community Commercial District. * The Oval Flats, PDP is proposed to be on a property that is included in the TOD overlay zone. COMMENTS: Background: The surrounding zoning and land uses are as follows: N: CC; Existing single family detached dwelling unit S: Not Zoned; Colorado State University Main Campus E: CC; Existing Multi -Family W: NCB; Existing Commercial (Woody's Standard Restaurant) The property is part of the original Map of the Town of Fort Collins, 1873; therefore, it has never had to be annexed. The site contains one large structure that was originally built in 1926 and used for a fraternity. There have been several alterations and additions to the building over time. It had been occupied as the Sigma Alpha Epsilon fraternity house until about 3 years ago. The structure is currently vacant. 2. Compliance with West Side Neighborhood Plan: The CC District was created to implement the vision and policies of the West Side Neighborhood Plan. The Neighborhood Plan was adopted prior to adoption of City Plan; however, the CC District was established and adopted as part of City Plan. The West Side Neighborhood Plan was adopted in 1989 and the property was shown on the Future Land Use map to be in the Retail/Mixed-Use Redevelopment Area. For background, the property was in the RH, High Density Residential District at the time of adoption of the West Side Neighborhood Plan and rezoned into the BL, Limited Business District between 1989 and 1997. 3 City of �,.ort Collins MEETING DATE STAFF 6,0 A. ►` HEARING OFFICER PROJECT: Oval Flats, Project Development Plan (PDP) - #26-08 APPLICANT: BP Laurel LLC c/o Kevin Brinkman 3003 East Harmony Road, Suite 300 Fort Collins CO 80528 OWNER: Colorado Delta Association of Sigma Alpha Epsilon c/o Dave Stewart 3801 Automation Way, Suite 200 Fort Collins, CO 80528 PROJECT DESCRIPTION: This is a request for a single mixed -use building containing 48 dwelling units, 3,012 square feet for the SAE Fraternity lodge space, and 4,585 square feet of commercial/retail space. The dwelling units would be divided between 10 one - bedroom units, 19 two -bedroom units, 16 three -bedroom units, 3 four -bedroom units. The proposed building is an L-shaped structure four stories (54'-1 ") in height and fronts on West Laurel and South Howes Streets. The lodge space, commercial/retail spaces, and 2 dwelling units would be on the first floor and the upper three floors would contain 46 dwelling units. There will be 58 on -site parking spaces to be accessed from the alley along the west side of the property. The site is located at the northwest corner of West Laurel Street and South Howes Street. The site presently contains the Sigma Alpha Epsilon fraternity house, although the building has been vacant for about 3 years. The existing structure is to be demolished if the PDP is approved. The site is 36,068 square feet (0.83 acre) in size, is zoned CC, Community Commercial, and is in the Transit -Oriented Development (TOD) overlay zone. RECOMMENDATION: Approval of the PDP Current Planning 281 PV College Av PO Box 580 Fort Collins, CO 80522-0580 fcgov.com/currentplanning 970.221.6750