HomeMy WebLinkAboutROLLAND MOORE CLEARWIRE WTF - PDP - 24-10 - SUBMITTAL DOCUMENTS - ROUND 1 - MAPS/GRAPHICSmII /,1 ELEVATION rIl zll 36"x72" PLATFORM DETAIL SCALE: 3/8" = I'4' NEW CABINET SECURITY LIGHTING Iz z SSC r CABINET MOUNTING DETAIL �SCALE: N.T.S. 0 i� BTS CABINET i-- RAISED STEEL PLATFORM rn--� EQUIPMENT PLAN L SCALE: 3/8" = 1'-0" NEW CABINET SECURITY LIGHTING SRE SUPPORT SITE SUPPORT CABINET CABINET ELECTRICAL PANEL POWER HVAC RECEPTACLE FOR UNIT PORTABLE GENERATORS CONNECTION TELCO BOX LTulsa, OK 74119 l PH: (918) 587-4630 , clear super fast mobile Internet 4400 CARILLON POINT j KIRKLAND, WA 98033 (425) 216-7600 OFFICE ISSUED FOR: REV DATE OESCPoPIIpI ZD Oa/18110 ZONING DRAWINGS ZD 110/18/101 ZONING DRAWINGS ZD 111/23/101 ZONING DRAWINGS PROJECT NO: 81937.000 DRAWN BY: 11 MO CHECKED BY: FSTEEL EQUIPMENT STEEL EQUIPMENT PLATFORM r PLATFORM CO-DEN1010 POWER PVC UI CONDUIT PVC POWER CONDUIT CONDUR TO ANTENNA SCHAD PVC TELCO CONDUIT CABINET ELEVATION ZUALt: J/6" = 1'-U" ROLLAND MOORE PARK 2201 SOUTH SHIELDS STREET FORT COLLINS CO 80526 PROPOSED LIGHT STANDARD SCHAD PVCjq.40 PVC SHEET TITLE CONDUIT TOER CONDUR EQUIPMENT CABINET, COAXANTENNA .40 PVC ROUTING &GATE DETAIL TELCO CONDUIT SHEET NUMBER: REVISION: MATCH STADUIM LIGHT W11 EXISTING STADUIM HEIGHT AND LIGHTS I I ENCLOSED SHROUD L- EXISTING 70' LIGHT POLE TO BE REPLACE WITH NEW 70' MONOPOLE AND LIGHTS OPENING TO BE CUT IN MESH AROUND _ FACE OF METER PROPOSED 10'-0'x10'-0' CLEARWIRE LEASE AREA (FENCED W/ SCREENING) TOP OF TOWER A ..._ ELEV. = 70' A.G.L. PROPOSED CLEARWIRE M/W ELEV. = 65' A.G.L. 0 PROPOSED CLEARWIRE ANTENNA ELEV. = 60` A.G.L. PROPOSED (3) SECTOR CLEAR WIRELESS STEALTH POLE MOUNTS W/(3) PANEL ANTENNAS & RRH PLUS (2) FLAT PANEL MICROWAVE ANTENNA NOTES: 1. VENDOR IS RESPONSIBLE FOR ACOUISRON OF BUILDING PERMIT PRIOR TO ANY CONSTRUCTION. / EXISTING 8'-0" / CHAIN —LINK FENCE AROUND BALLFIELD / (j)TOWER ELEVATI 1 1 1 (SECTOR 0) 0' AZIMUTH / 2-3/8" O.D. ` J STD PIPE / 7 STEALTH SHROUD / (M/W 2) 223.36' AZIMUTH ANDREW VHLP2-23'24' MICROWAVE DISH C ANDREW MC—RM1030-3 UNIVERSAL MOUNT WITH (3) 2-3/8" O.D. .PIPE x / 16'-0" MOUNTS 12' TO 364� — PANEL ANTENNA POWERWAVE (REF)MONOP65-18—XXW2—R (1) PER SECTOR, (3) SECTORS (TYP) (SECTOR 3) BTS / /(SE 1TOR 20' 2) AZIMUTH AZIMUTH 1. ALL ANTENNAS FURNISHED WITH DOWNTILT BRACKETS. CONTRACTOR TO COORDINATE REQUIRED MECHANICAL DOWNTILT FOR EACH ANTENNA WITH RF ENGINEER. 2. ANTENNA CENTERLINE HEIGHT IS IN REFERENCE TO HEIGHTS SHOWN ON TOWER ELEVATIONS. 3. CONTRACTOR SHALL VERIFY ANTENNA TYPE, CABLE TYPE, AND AZIMUTH WITH RF ENGINEER AND/OR CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. 4. LOCAL MAGNETIC DECLINATION FACTOR, PER THE NATIONAL GEOPHYSICAL DATA CENTER IS 9' 11' E CHANGING BY 0' 8' PER YEAR. ANTENNA PLAN VIEW SCALE: N.T.S. / + ENLARGED LEASE AREA _//w//,N_ 1 (3) PROPOSED 6.0 PVC CONDUITS UNDERGROUND FOR CABLING. EXISTING LIGHT POLE TO BE REPLACED WITH NEW 70' MONOPOLE/UGHTPOLE LOCATION OF NEW 70' MONOPOLE WITH LIGHTS EXISTING 8'-0" HIGH CHAIN —LINK FENCE \ WITH POST AT 10'-0', O.C. 1717 S Boulder Suite 300 Tulsa, OK 74119 PH: 918 587-4830 clear super fast mobile Internet 4400 CARILLON POINT KIRKLAND, WA 98033 (425) 216-7600 OFFICE ISSUED ZD OD/18/10 ZONING DRAWINGS ZD 10/18/10 ZONING DRAWINGS PROJECT NO: 81937.000 DRAWN BY: - MOW CHECKED BY: SIA L A CO—DEN1010 ROLLAND MOORE PARK 2201 SOUTH SHIELDS STREET .FORT COLLINS CO 80526 PROPOSED LIGHT STANDARD SHEET TITLE ELEVATION, ENLARGED. PLAN AND ANTENNA PLAN SHEET NUMBER: REVISION: A2 Z D 11 Y I� NNOGY EXISTING STREAM \ EXISTING BALLFlELD \ f + EXISTING 8'-0" + CHAIN—UNK FENCE AROUND BALLFIELD \+ �I •t`t••fr PP 4 PROPOSED 8' CHAIN--� LINK FENCE ''� •'•i1.�f < `7 �'>'F ` /,, SURROUND COMPOUND r n------------ ';� UGP— UGUGP— UGC UGP— ucP—� P— i i OCp/ PROPOSED UNDERGROUND ELECTRICAL ROUTE TO �M1 T• i EXISTING VAULT EXISTING DRIVE •i� 7 ih� AT,, � '<k NEW SINGLE PHASE TRANSFORMER 120/240V TO BE INSTALLED. COORDINATE WITH LOCAL UTILITY COMPANY. (9° 11' E c changing by 0 0' a') MA tots go r4--N SITE LAYOUT SCALE: 1" = 501Y EXISTING PARKING EXISTING PARKING. RE 2/A2 FOR CLEARWIRE LEASE AREA EXISTING 70' TOWER. + PROPOSED 70' REPLACEMENT TOWER GENERAL NOTES: 1. THE LATERAL SEISMIC FORCE FOR EQUIPMENT CABINET ANCHORAGE DESIGN PER THE (2003 INTERNATIONAL BUILDING CODE/ ASCE STANDARD)(SE1/ ASCE 7-02) STANDARD IS: Fp=0.54Wp (FOR ASD DESIGN) 2. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED BY FIELD MEASUREMENT. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. 3. THE GENERAL CONTRACTOR AND HIS SUBCONSULTANTS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS WHICH MAY BE REQUIRED FOR THE WORK. 4. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE AISC SPECIFICATIONS FOR STRUCTURAL STEEL BUILDING ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE AISC CODE OF STANDARD PRACTICE. 5. STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM A36. ALL STRUCTURALL STEEL PIPES SHALL CONFIRM TO ASTM A53 GRADE B. ALL STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500 GRADE B. ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ASSEMBLIES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. 6. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS) D.1.1-96 STRUCTURAL WELDING CODE —STEEL WELD ELECTRODES SHALL BE E70XX. FIELD TOUCH UP WITH ZINC RICH PAINT (ALL EXISTING AND NEW AREAS) AFTER WELDING IS COMPLETE. 7.. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLIES SHALL CONFORM TO ASTMA307 OR ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERSSHALL BE INCH MIN. DIAMETER BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED IN THE SHEAR PLANE. ALL EXPOSED FASTENERS, NUTS AND WASHERS SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. CONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK BOLTS UNLESS OTHERWISE NOTED. ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL. - \ 8. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL BE SPECIFIED -t BY THE OWNER AND IS NOT INCLUDED IN THESE CONSTRICTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALL CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. ETHERNET CABLES SHALL BE ATTACHED TO THE TOWER HARDWARE REQUIRED TO SECURE THE CABLES. ETHERNET CABLE SHALL BE ATTACHED TO THE TOWER WAVE GUIDE LADDER USING UV —RESISTANT TIE WRAPS OR STAINLESS STEEL HARDWARE 9. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE -NORTH. CONTRACTOR SHALL VERIFY NORTH AND INFORM ARCHITECT/ENGINEER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. 10. ALL REINFORCING STEEL SHALL CONFORM TO ASTM 615 GRADE 60, DEFORMED BILLETSTEEL BARS. WELDED WIRE FABRIC REINFORCING SHALL CONFORM TO ASTM A185. \ 11. EQUIPMENT ENCLOSURE SHALL BE CMU BLOCK STRUCTURE WITH A BRICK VERNER TO MATCH EXISTING BUILDING. ENCLOSURE TO BE SECURED WITH CHAIN LINK GATE 6'-0" IN HEIGHT AND CHAIN LINK COVER ON TOP. ALL COMPONENTS . SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153. 12. FENCED SITE AREA SHALL BE CLEARED AND CLEARED AND GRUBBED. REMOVE UNSUITABLE SOFT OR LOOSE SOILS, ORGANIC MATERIAL AND OR RUBBLE TO FIRM SUBGRADE. FILL UNDERCUT UP TO 4 INCHES BELOW FINISH GRADE. PLACE A 150 MIL WOVEN GEOTEXTILE FILTER FABRIC ON SUBGRADE AND FILL WITH 4 INCHES OF AASHTO 57 STONE TO FINISH GRADE. 13. CONCRETE FOR THE EQUIPMENT PAD SHALL BE 2500 PSI NORMAL WEIGHT CONCRETE WITH FIBERMESH ADMIXTURE. CONTRACTOR MAY USE APPROVED PRECAST EQUIVALENT. 14. LUMBER SHALL COMPLY WITH THE REQUIREMENTS OF AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AND THE NATIONALFOREST PRODUCTS ASSOCIATION'S NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. ALL LUMBER SHALL BE PRESSURE TREATED AND SHALL BE STRUCTURAL GRADE NO. 2 OR BETTER. 15. PLEASE REFER TO THE STRUCTURAL ANALYSIS FOR ANY AND ALL INFORMATIONREGARDING THE PROPOSED LOADING. 16. ALL FIELD CUT METAL WILL BE SCRAPED OF ANY RUST AND COLD GALVANIZED. 17. RUBBER CAPS WILL BE PLACED ON ALL EXPOSED UNISTRUT ENDS. 1717 S Boulder Suite 300 Tulsa, OK 74119 PH: (918) 587-4630 dearhllle super fast mobile Internet 4400 CARILLON POINT KIRKLAND, WA 98033 (425) 216-7600 OFFICE ( ISSUED FOR: 1 i ZD 109/16/101 ZONWG ORAWWGS I PROJECT NO: 81937.000, DRAWN BY: CHECKED BY: W it IS A VIO ANON OF LAW FOR ANY PERSON, UNLESS 1NV ARE ACiINB UNDER THE DwECOON OF A LICENSED PROFESIroai E1404E L TO I M 1 UDCUI/ENr. CO—DEN1010 ROLLAND MOORE PARK 2201 SOUTH SHIELDS STREET FORT COLONS CO 80526 PROPOSED LIGHT STANDARD SHEET TITLE SITE LAYOUT SHEET NUMBER: REVISION: Al ZD NOTES: 1. THIS IS NOT A LEGAL SURVEY. NO SURVEY OF THIS PROPERTY WAS PERFORMED. 2. THE BOUNDARIES, AREAS. AND PROPERTY INFORMATION WERE COMPILED FROM AN AERIAL PHOTOGRAPH AND ARE NOT ACCURATELY LOCATED. ml of n iI changing by III N 8 o 1 8') MAC NI$8 to o F ZONING MAP SCALE: N.T.S. FJnI121J LEGAL DESCRIPTION: BEG AT PT ON N LN OF NW 19-7-68 N 89 41 40 E 1497.15 FT FROM NW COR. S 0 18 20 E 90 Fr. TH SWIRLY ALG 14 21 CUR R. 229.97 FT; S 32 41 40 W 150 FT; TH SRLY ALC 14 52 CUR L. 204.24 Fr; S 2 20 40 W 369.67 Fr; S 89 39 20 E 617 FT; S t 1 05 20 E 681.7 FT; S 89 29 50 E 400.91 FT; N 1 31 40 E 458.3 FT; N 80 25 40 E 1479.44 FT TO PT ON W R/W LN OF UP RR; N 0 3 20 W 583.4 FT ALG SO R/W; 5 74 36 40 W 790.81 FT, N 79 16 50 W 225.79 FT; N 86 32 20 W 578.58 Fr; N 55 54 50 W 639.G3 FT; TH N 0 18 20 W 155 FT TO Pr ON N LN OF NW 1/4; S 89 41 40 W 277.5 FT TPOS. (45.591 AC) r. Ty1 WITH OPEN PITS EACH END NpIGE DESMUC1pN TO 1717 S Boulder Suite 300 Tulsa, OK 74119 PH' (918)587-4630 clear �0 super fast mobile Internet 4400 CARILLON POINT KIRKLAND, WA 98033 1425) 216-76W OFFICE ISSUED FOR: fiEY WTE RSCRWfgN i ZD 110/13/101 ZONING DRAWINGS 1 PROJECT NO: $1937.000 DRAWN BY: MDW I CHECKED BY: $EM , I CO—DEN1010 ROLLAND MOORE PARK 2201 SOUTH SHIELDS STREET FORT COLLINS CO 80526 PROPOSED LIGHT STANDARD SHEET TITLE ZONING MAP SHEET NUMBER: REVISION' Z1 ZD clear super fast mobile internet PROJECT SUMMARY SITE NAME: ROLLAND MOORE PARK SITE NUMBER: CO—DEN1010 . SITE ADDRESS: 2201 SOUTH SHIELDS STREET FORT COLONS CO 80526 JURISDICTION: CITY OF FORT COLLINS TOWER OWNER: CLEARWIRE, LLC 4400 CARILLON POINT KIRKLAND WA 98033 ANTHONY PANELU NAD83 (425) 216-7600 LATITUDE: 40.557031 N LONGITUDE: —105.100658 W GROUND ELEVATION: 5037' AMSL LANDLORD: QUINN KAISER—OOCHRAN 2323 DELGANY STREET DENVER. CO CUSTOMER SERVICE (303) 359-0089 CUSTOMER/APPLICANT: CLEARWIRE, LLC 4400 CARILLON POINT KIRKLAND, WA 98033 (425) 216-7600 OFFICE (425) 216-7900 FAX OCCUPANCY TYPE: UNMANNED A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CONTACT INFORMATION ENGINEER: B&T ENGINEERING, INC 1717 S. BOULDER, SUITE 300 TULSA, OK 74119 STEVE MANUEL (918) 587-463.0 SURVEYOR: HUSKER SURVEYING 4525 NORMAL BLVD.. SUITE 165 LINCOL.N, NE 68506 JAYME MALONE (402) 423-5202 ELECTRIC PROVIDER: PLATTE RIVER POWER AUTHORITY (970) 226-4000 CUSTOMER SERVICE TELEPHONE PROVIDER: QWEST COMMUNICATIONS (800) 777-9594 CUSTOMER SERVICE SITE NUMBER CO=DEN1010 SITE NAME • 0 ' PROPOSED 70f LIGHT STANDARD VICINITY MAP re ''.:'� s - s 7 I ""'a•.T"' .ter E Eli- E 6$ rN i ,• �, z 6.{I ��LJrz 'V �#}},, � CQNKNLOIp •vTi075 ROLLAND HOO 1 � •i � p1} .. a �-. w W Ms 44 ^S z 1 ,(' ' k"'✓w m[��YS i ¢ � � k��'i�P N loi LOIT1•YI ..� a �'`�` {Y Jr : i r � i r ~� � � ��,I �y Q Ail` S e���rK ,. r`: '�9�h 'n � A ,+'J' f., Z�A9 •'M 6. c ��11j,+�, '�� !.�` h uA ,��{.'M`.g�F ,.� 9 �•,p � k II � 'per r t i>ai%•v t Ic'I?,-''a"s s .. c �: n y 41L r I ., .r ? 'U :K NO SCALE DRIVING DIRECTIONS TAKE PENA BOULEVARD TO EXIT 68 TO MERGE ONTO E-470 FOR 17.5 MILES. TAKE EXIT 47 TOWARDS 1-25/DENVER/FT COLLINS FOR 37.5 MILES. AT EXIT 265 TAKE RAMP TO HARMONY RD, TURN LEFT (WEST) ONTO SR-68 (E HARMONY RD)'FOR 4.5 MILES, TURN RIGHT (NORTH) ONTO CR-17 (S SHIELDS ST) FOR APPROX. 1.9 MILES TURN LEFT (WEST) ON LOCAL ROAD ARRMNG AT SITE. CODE COMPLIANCE 1 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDTIIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE S;.4QE j BUILDING/DWELUNG IBC 2006 STRUCTURAL IBC 2006 MECHANICAL IMC 2006 ELECTRICAL NEC 21105 I . PROJECT DESCRIPTION l THE PROPOSED PROJECT INCLUDES • ATTACH (3) NEW ANTENNAS TO FACE OF TOWER AT 60% • ATTACH (2) NEW MICROWAVE DISHES TO FACE OF TOWER AT 60' • CONSTRUCT NEW CMU COMPOUND TO CONCEAL EQUIPMENT. • CONSTRUCT NEW PLATFORM TO SUPPORT EQUIPMENT. • INSTALL POWER UTILITIES. • INSTALL NEW CROUNDING SYSTEM. . DRAWING INDEX SHEET NO. SHEETTITLE REV. T1 TITLE SHEET ZD Zt ZONING MAP ZD Al SITE LAYOUT & ENLARGED SITE PLAN ZD A2 ELEVATION, ENLARGED SITE PLAN & ANTENNA PLAN ZD A3 EQUIPMENT CABINET, COAX ROUTING & GATE DETAIL ZD APPROVAL LIST TITLE SIGNATURE DATE CLEARWIRE CONSTRUCTION MGR: RF ENGINEER: ZONING APPROVAL* SITE ACQUISITION: PROPERTY OWNER: DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING OIMENSIONSAND CONDITIONS ON THE JOB SRE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME SEE SHEETS GN1 AND GN2 FOR ADDITIONAL CONSTRUCTION NOTES. UNDERGROUND Know what's below SERVICE Call before you dig. ALERT 1-800-922-1987 1717 S Boulder Suite 300 Tulsa, OK 74119 clear(g super fast mobile Internet 4400 CARILLON POINT KIRKLAND, WA 98033 (425) 216-7600 OFFICE ISSUED FOR: 1 ZO OB/16/10 ZONING DRAWINGS ZO to/1e/to ZONING DRAL PROJECT NO: 81937.000 DRAWN BY: MOW CHECKED BY: ,jrl�l R a A Wa,aM OF LAW FOR ANIY PEIMK um1 ARE ACDNO MDER R@ aRCCIroN OF.A MCUM PROFESIOEAM. IMANEER, To ALTER 110E DOCUMENT. CO—DEN1010 ROLLAND MOORE PARK 2201 SOUTH SHIELDS STREET FORT COLLINS CO 80526 PROPOSED LIGHT STANDARD SHEET TITLE TITLE SHEET SHEET NUMBER: REVISION: T1 jZDj