HomeMy WebLinkAbout429 S. WHITCOMB STREET CARRIAGE HOUSE - PDP - PDP130006 - REPORTS -GENERAL NOTES: PROJECT: CARRIAGE DRAWING NOTES: 1. CONTRACTOR TO EXAMINE AND VERIFY ALL DIMENSIONS AND CONDITIONS BOTH ON THE PLANS AND IN THE FIELD, AND BE RESPONSIBLE FOR ANY ADJUSTMENTS AND/OR CORRECTIONS. 2. CONTRACTOR SHALL IMMEDIATELY NOTIFY ARCHITECT/ENGINEER OF ANY ERRORS, CONFLICTS OR INCONSISTENCIES FOUND ON THE PLANS DURING THE DEVELOPMENT OF THE PROJECT. 3. ALL DIMENSIONS ARE TO ROUGH FRAME OR CONCRETE FACE UNLESS NOTED OTHERWISE. 4. 2x6 WALLS ARE DRAWN AT 5 1/2' WIDTH. 2x4 WALLS ARE DRAWN WITH A 3 1/2' WIDTH. 5. DO NOT SCALE DRAWINGS, FOLLOW DIMENSIONS ONLY. GENERAL CONSTRUCTION: I. CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE (IRC), RECENT EDITION AS ADOPTED, BY THE LOCALITY OF THE BUILDING SITE. 2. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL STATE AND LOCAL CODES. SECURE ALL APPROVALS AND PERMITS AND APPROVALS PRIOR TO ANY CONSTRUCTION. B. ALL MASONRY CONSTRUCTION TO COMPLY TO THE CURRENT EDITION OF ACI 'CONCRETE MASONRY STRUCTURES - DESIGN AND CONSTRUCTION". 4. EXTERIOR GRADE FILL SHALL SLOPE A MINIMUM OF LIO AWAY FROM BUILDING. 5. SLOPE ALL EXTERIOR CONCRETE FLATWOOK 1/4' PER FOOT AWAY FROM BUILDING TO PROVIDE PROPER DRAINING. 6. CONTRACTOR SHALL LOCATE AND VERIFY UTILITY SIZES AND HOOKUPS/ TAPS. 1. COORDINATE LOCATION OF UTILITY METERS WITH SITE PLAN AND LOCATE AWAY FROM PUBLIC VIEW. VISUAL IMPACT SHALL BE MINIMIZED, I.E. MOUNT AS LOW AS POSSIBLE. 8. ALL CONCRETE TO BE 3000 P.S.I. MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, UNLESS NOTED OTHERWISE. q. ALL FRAMING LUMBER TO BE 14EM-FIR 02 OR BETTER. FB = 1150 P.S.I. E = 1,100,000 PS.I., UNLE55 NOTED OTHERWISE 10. ALL REINFORCING TO BE DEFORMED TYPE, 60 GRADE STEEL. MINIMUM SPLICE LENGTH I'-q'. II. ALL STRUCTURAL STEEL SHALL CONFORM WITH ASTM SPECIFICATION A-36. 12. GUTTERS AND DOWNSPOUTS ARE NOT SHOWN FOR CLARITY. LOCATE DOWNSPOUTS IN LEAST VISUALLY OFFENSIVE LOCATIONS. FOR EXAMPLE, FRONT WALL OF HOUSE, BESIDE PORCH COLUMNS, ETC. GENERAL CONTRACTOR SHALL VERIFY EXISTING GRADES AND COORDINATE ANY NECESSARY ADJUSTMENTS TO HOUSE WITH OWNER. 13. CONTRACTOR SHALL FIELD VERIFY ALL CABINET DIMENSIONS BEFORE FABRICATION. 14. CONTRACTOR SHALL COODINATE ALL CLOSET SHELVING REQUIREMENTS. IS. SMOKE DETECTORS AND/OR CARBON MONOXIDE DETEGTORES ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS IN ALL SLEEPING AREAS AND IN CORRIDORS. FOUNDATION 4 CONCRETE: I. UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE SHALL BE 3000 P.B.I. (28 DAY COMPRESSIVE STRENGTH) CONCRETE ON 4' SAND OR GRAVEL FILL MINIMUM WITH 6x6 - WI.4xWl.4 WWM REINFORCING. INTERIOR SLABS SHALL BE PLACED ON 6 MIL STABILIZED POLYETHYLENE VAPOR BARRIER. 2. PROVIDE 1/2' EXPANSION JOINT MATERIAL BETWEEN ALL CONCRETE SLABS AND ABUTTING CONCRETE OF MASONRY WALLS OCCURRING IN EXTERIOR OR UNHEATED INTERIOR AREAS. 3. CONTRACTOR TO VERIFY FOOTINGS DEPTH WITH LOCAL FROST REQUIREMENTS OR EXISTING SOIL CONDITIONS, WHICHEVER IS MORE RESTRICTIVE. 4. PLACE 1/2' DIAMETER X (8' OR 127 SILL PLATE ANCHOR BOLTS AT EACH VERTICAL REBAR (WHERE OCCURRING) OR AT 4'-O. O.C. AND AT EACH CORNER AND BOTH SIDES OF OPENINGS. 5. PROVIDE TERMITE PROTECTION AS REQUIRED BY LOCAL CODES. 6. PROVIDE DEEP SCORE CONTROL JOINTS AT MID POINTS OF ALL GARAGES, BOTH DIRECTIONS. 1. MASONRY VENEER MUST BE ANCHORED TO BACK-UP CONSTRUCTION WITH GALVANIZED CORRUGATED METAL TIES SPACED 16' O.G. HORIZONTALLY AND 24' O.C. VERTICALLY. B. PROVIDE WATERPROOFING OF ALL FOUNDATIONS WALLS PER STRUCTURAL ENGINEERS RECOMMENDATIONS. FRAMING: I. UNLESS NOTED OTHERWISE, PROVIDE DOUBLE HEADER JOISTS AND TRIMMERS AT ALL FLOOR OPENINGS, DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS, DOUBLE 2x12 HEADERS WITH 1/2" PLYWOOD, GLUED BETWEEN AND NAILED, FOR ALL OPENINGS IN 2x6 WALLS. DOUBLE 2x12 HEADERS NAILED TOGETHER FOR ALL OPENINGS IN 2x4 WALLS. 2, PROVIDE A 6" MIN. CLEARANCE FROM EXTERIOR FINISH TO THE TOP OF GRADE. 3. ALL HEADERS SHALL BE FRS FROM ALL SPLITS, CHECKS, OR SHAKES. 4. ALL WOOD PLATES IN CONTACT WITH CONCRETE SHALL BE 'PRESSURE TREATED" 3 SILICONE SEALED. 5• FLOOR CONSTRUCTION SHALL BE 3/4' TONGUE AND GROOVE SUBFLOOR WITH FINISH MATERIAL OVER. 6. FLOOR FRAMING LAYOUT SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AND -VAC CONTRACTORS TO PROVIDE ACCESS CHASES AND UNOBSTRUCTED RUNS FOR -VAC DUCT WORK. FLOOR TRUSS LAYOUT TO BE ENGINEERED BY TRUSS MANUFACTURER. T• CONTRACTOR TO PROVIDE FLOOR, WALL AND ROOF FIREBLOGKING PER CODE. 8. CONTRACTOR TO PROVIDE FIRESTOP ALL POCKET DOORS AND FLUES. q. WALLS AND CEILING COMMON TO GARAGE AND HOUSE SHALL HAVE A LAYER OF TYPE 'X' GYPSUM BOARD AT GARAGE SIDE. 10. ALL INTERIOR WALLS SHALL BE COVERED WITH 1/2' GYPSUM BOARD, WITH CORNER REINFORCING. TAPE, FLOAT AND SAND (3 COATS) USE 5/8' GYPSUM BOARD ON CEILINGS WHEN SUPPORTING MEMBERS ARE 24. OR GREATER. USE 1/2' GYPSUM BOARD ON CEILING MEMBERS LESS THAT 24' O.G. INSULATION NOTES: 1. INSULATION, BATT OR BLOWN SHALL HAVE AN R-RATING AS DICTATED BY LOCAL CODE. 2. REFER TO LOCAL CODE FOR OPTIMUM THERMAL PERFORMANCE CRITERIA. 3• PROVIDE R-Iq BATT INSULATION IN 2x6 WALLS, R-13 IN 2x4 WALLS, MINIMUM R-38 INSULATION IN FLAT CEILINGS AND R-30 BLANKET INSULATION IN VAULTED CEILINGS. ALLOW 1/2' MINIMUM AIRSPACE BETWEEN SHEATHING AND INSULATION, FACE FOIL DOWN TO WARM SIDE. 4. INSTALL SIDE WALL AND CEILING INSULATION IN CONTINUOUS BLANKETS WITHOUT HOLES FOR ELECTRICAL BOXES, LIGHT FIXTURES OR HEATING DUCTWORK. CAULK ALL OPENINGS IN EXTERIOR WALL CONSTRUCTION. 5. INSTALL 6 MIL. POLYETHLENE VAPOR BARRIER AGAINST INSIDE OF ALL INSULATION. LAP JOINTS 18" MINIMUM. 6. FLOORS OVER UNHEATED SPACE SHALL HAVE A R-25 FOIL BACK INSULATION BETWEEN JOISTS. "I. -VAC DUCTS LOCATED IN UNHEATED SPACES SHALL BE INSULATED WITH R-8. S. ALL EXPOSED INSULATION SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450. q. INSULATE ALL CANTILEVERED FLOORS WITH BATT INSULATION AND SHEATH THE UNDERSIDE WITH HARDBOARD OVER APPROVED VAPOR BARRIER. ROOFING NOTES: I. PROVIDE INSULATION BAFFLES AT EAVE VENTS BETWEEN RAFTERS/ TRUSSES. 2. RIDGES, VALLEY AND HIP MEMBERS SHALL BE FULL VERTICAL DEPTH OF FRAMING MEMBERS. 3. EXTERIOR FLASHING SHALL BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS, WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTION PRACTICES. VENTILATION 4 FIREPLACE: I. PREFABRICATED FIREPLACE CONSTRUCTION SHALL MEET OR EXCEED ALL APPLICABLE CODES REGARDING USE OF FIRE SEPARATIONS, CLEARANCES, ETC. IT IS THE CONTRACTORS RESPONSIBILTY TO ENSURE THAT ALL ITEMS AND CONSTRUCTION MEET OR EXCEED CODE. 2. PROVIDE COMBUSTION AIR VENTS, WITH SCREEN AND BACK DAMPER, FOR FIREPLACES, WOOD STOVES AND ANY APPLICANCE WITH AN OPEN FLAME. 3. ALL FIREPLACE CHASE WALLS SHALL BE INSULATED INSIDE AND OUTSIDE. PROVIDE HORIZONTAL 'DRAFT STOPS' AT EACH FLOOR LEVEL BY PACKING 6' (R-Icl) INSULATION BETWEEN 2x4 JOISTS. 4. MAINTAIN PROPER CLEARANCE AT FIREPLACE. VENT OPENING PER MANUFACTURERS SPECIFICATIONS 5. BATHROOMS AND UTILITY ROOMS SHALL BE VENTED TO THE OUTSIDE WITH A MINIMUM OF A 40 CFM FAN. 6. RANGE HOODS SHALL BE VENTED TO OUTSIDE. 1. PLUMBING AND HVAG VENTS SHALL BE GROUPED IN ATTIC TO LIMIT ROOF PENETRATIONS AND BE LOCATED AWAY FROM PUBLIC VIEW, I.E. AT THE REAR OF THE HOUSE AND SHALL BE PRIMED AND PAINTED TO MATCH ROOF COLOR. 8. CONTRACTOR SHALL PROVIDE ADEQUATE ATTIC VENTILATION/ ROOF VENTS PER LOCAL GOVERNING CODE. PROVIDE CONTINUOUS RIDGE VENTILATION, WHERE APPROPRIATE, AND PAINT TO MATCH ROOF. INSTALL SOFFIT VENTILATION AT OVERHANGS. q. PROVIDE CRAWL SPACE FOUNDATIONS WITH VENTILATION PER LOCAL CODE REQUIREMENTS. MECHANICAL, PLUMBING 4 ELECTRICAL: I. LOCATE MECHANICAL DUCTS, FLUES AND EQUIPMENT AS REQUIRED. COMPLY WITH ALL STATE/LOCAL CODES. 2. COMBUSTION AIR FOR FURNACES AND WATER HEATERS MUST COMPLY THE INTERNATIONAL MECHANICAL CODE. TWO 6' DUCTS ARE REQUIRED, WITHIN 12" OF THE FLOOR AND WITH 12" OF THE CEILING. 3. ATTIC -VAC UNITS SHALL BE LOCATED WITHIN 20' OF ITS SERVICE OPENING. RETURN AIR GRILLES SHALL NOT BE LOCATED WITHIN 10 FEET OF A GAS FIRED APPLIANCE. 4. PROVIDE ELECTRICAL SERVICES AS REQUIRED TO COMPLY WITH ALL STATE d LOCAL CODES. ALL NEW FIXTURES TO BE APPROVED BY OWNER. 5. PLUMBING SHALL MEET ALL LOCAL CODES. 6. IN ALL BATHROOMS CONTAINING A BATHTUB, SHOWER, WATER CLOSET, LAVORATORY, A COMBINATION THEREOF, LAUNDRY ROOMS, AND SIMILAR ROOMS THAT DO NOT HAVE ACCESS TO NATURAL VENTILATION, A MECHANICAL VENTILATION SYSTEM CONNECTED DIRECTLY TO THE OUTSIDE IS TO BE PROVIDED. - . IF WATER HEATER IS LOCATED ANWHERE, EXCEPT GARAGE OR BASEMENT, PROVIDE DRAIN PAN WITH AUXILLARY DRAIN TO EXTERIOR. B. ALL GAS WATER HEATERS SHALL BE VENTED AT TOP OUT. q. CONTRACTOR TO PROVIDE INSIDE MAIN WATER CUT-OFF. 10. ALL BATH AND TOILET AREA WALLS AND CEILINGS SHALL HAVE WATER RESISTANT GYPSUM BOARD. 11. FIBER -CEMENT, FIBER MAT REINFORCED CEMENT, GLASS MAT GYPSUM BACKERS AND FIBER -REINFORCED GYPSUM BACKERS INSTALLED ACCORDING TO MANUFACTURERS RECOMMENDATIONS SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. 12. ALL PLUMBING PENETRATIONS THROUGH DRYWALL ARE TO BE FULLY SEALED. IS. PROVIDE BLOCKING IF WALL PLATES OR JOINTS ARE CUT INTO. 14. SHOWERS AND TUB -SHOWER UNITS MUST BE PROVIDED WITH CONTROL VALVES OF THE PRESSURE BALANCE/ THERMOSTATIC MIXING VALVE TYPE. WATER TEMPERATURE SETTING IS 120OF MAX. 6�eM��:f3����1!rc7l:rd�1_ 1IIr�.'��il�i�e�.�;l�PI�� � •.I�I'.Ca STAIRS, GARAGE, HALLS $ RAMP: 1, STAIRS SHALL BE A MIN. OF 36' CLEAR WIDTH, WITH A 7-3/4' MAX. RISE, AND 10" MIN. TREAD DEPTH. HEADROOM SHALL BE 6'-8" MIN. CLEAR OF ANY OBSTRUCTION. 2. INTERIOR AND EXTERIOR STAIR LANDINGS SHALL BE A MIN. OF 36' IN WIDTH AND DEPTH. 3. ANY ENCLOSED USABLE SPACE BENEATH ANY STAIR TO BE CONSTRUCTED WITH A ONE HOUR FIRE RATING. CONTRACTOR TO OBTAIN THIS RATING BY CONSTRUCTING THE WALLS AND SOFFITS OF THE ENCLOSURE WITH 5/8' TYPE 'X' GYPSUM WALL BOARD. 4. ALL SURFACES THAT DEFINE THE VERTICAL OR HORIZONTAL SEPARATION BETWEEN THE GARAGE AND HOUSE ARE TO BE PROTECTED WITH 5/8" TYPE 'X' GYPSUM WALL BOARD. THIS INCLUDES ALL HORIZONTAL AND VERTICAL STRUCTURAL SUPPORT MEMBERS SUPPORTING THE SEPARATIONS ON GARAGE SIDE ONLY. 5. ALL HALLWAYS AND CORRIDORS TO MAINTAIN A 36" MIN. CLEAR WIDTH. 0. GUARDRAILS ARE TO HAVE 3 -1/8' MAXIMUM SPACING AND BE 34'-38' IN HEIGHT. T• STAIR CONSTRUCTION SHALL CONSIST OF (3) 2x12 STRINGERS, 5/4' OR 2x THICK TREADS AND 3/4" THICK RISERS OR MATERIALS FABRICATED BY A COMPONENT MANUFACTURER. 8• HANDRAILS SHALL BE MOUNTED 34"-38', MEASURED VERTICALLY FROM THE SLOPED PLAN ADJACENT TO TREAD NOSING. q• RAMPS SHALL HAVE A 1:8 MAXIMUM SLOPE. A 3'x3' LANDING SHALL BE PROVIDE AT TOP AND BOTTOM OF RAMP, WHERE RAMP CHANGES DIRECTION AND WHERE A DOOR OPENS ONTO RAMP. 10. RAMPS WITHOUT A HANDRAIL SHALL HAVE A 1:8 MAXIMUM SLOPE. 11. RAMPS WITH A HANDRAIL SHALL HAVE A 1:12 MAXIMUM SLOPE. 12• HANDRAILS SHALL BE 34'-38" IN HEIGHT ABOVE THE RAMP FINISHED SURFACE 13. A sx3' LANDING SHALL BE PROVIDE AT TOP AND BOTTOM OF RAMP, WHERE RAMP CHANGES DIRECTION AND WHERE A DOOR OPENS ONTO RAMP. DOORS/ WINDOWS: 1. ALL WINDOW SIZES SHOULD BE VERIFIED WITH OWNERS REPRESENTATIVE PRIOR TO PURCHASE. GLAZING WITHIN 24. OF A DOOR, MUST BE TEMPERED SAFETY GLASS. 2. ALL WINDOWS E EXTERIOR DOORS ARE TO BE WEATHER-STRIPPED. 3. ALL DOORS LEADING TO GARAGE FROM ANY LIVING SPACE ARE TO BE A MIN. 204MINUTE FIRE RATED R EQUIPED WITH AN AUTOMATIC CLOSER DEVICE. 4. "CENTERED' IMPLIES CENTER THE OPENING ON THE WALL SECTION, WITH EQUAL REVEAL ON EACH SIDES. CENTER ALL OPENINGS UNLESS OTHERWISE NOTED. 5. EXTERIOR DOOR DESIGNATIONS ARE NOMINAL. CASING WILL BE A 2 1/2' REVEAL. 6• WINDOW SIZES INDICATED ON PLANS ARE NOTED BY APPROXIMATE ROUGH OPENING SIZE. REFER TO PLANS AND EXTERIOR ELEVATIONS FOR WINDOW TYPES. 1. BEDROOM WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7I SQ. FT., A MINIMUM NET CLEAR OPENABLE WIDTH OF 20', A MINIMUM NET CLEAR OPENABLE HEIGHT OF 24', AND HAVE A MAXIMUM FINISH SILL HEIGHT OF 43' FROM FINISH FLOOR. 8. ALL GLASS LOCATED WITHIN 18" OF FLOOR, OR LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS, SHOWERS, SAUNAS, STEAM ROOMS OR HOT TUBS SHALL BE TEMPERED. z 0 a 0 w z w rc w m J x m F S. WHITCOMB ST. r COLLINS, CO 21 PREPARED FOR: CONOR FLANAGAN PA. BOX 1832 FORT COLLINS, GO SM22 501 3Oi-gO58 conorflanagailOOogmall com I DESIGNED BY: /AINBIRD Design ARCHITECTURAL SERVICES (970) 690-1433 TELE. raynebyrd@gmall.com BY: RM DATE: 3/5/13 SCALE: REV: FOR PERMIT DATE: 3/2q/13 BY. RMI REV: DATE: BY. REV: DATE: BY: TITLE: GENERAL NOTES I SHEET: Ar .O