HomeMy WebLinkAboutHARMONY TECH. PARK THIRD FILING, SECOND REPLAT (CUSTOM BLENDING) - PDP/FDP - FDP130021 - CORRESPONDENCE - (5)Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford(iDfcgov.com Topic: Construction Drawings Comment Number: 2 Comment Originated: 06/03/2013 Please remove the Stop Bars, Crosswalk striping and Stop signs on the two access drives intersecting Precision Drive. Traffic Op's does not sign or stripe driveway accesses. Topic: Traffic Impact Study Comment Number: 1 Comment Originated: 06/03/2013 Traffic Op's acknowledges allowance of a late submitted TIS. Department: Zoning Contact: Noah Beals, 970-416-2313, nbealsO fmov.com Topic: General Comment Number: 1 Comment Originated: 05/24/2013 The ROW landscape improvements need to be carried all the way through to the east property line. Comment Number: 2 Comment Originated: 05/24/2013 Loading area the minimum average should be 5 foot candle. The proposed average is less than 5 fc. Custom Blending PDP/FDP #FDP 13002 — Round 1 Comment Letter Page 2 June 7, 2013 Please remove "Custom Blending" from the title block on all sheets. Comment Number: 7 Comment Originated: 06/05/2013 There are lines over text issues on sheet LS 1. See redlines. Comment Number: 8 Comment Originated: 06/05/2013 Please mask all text in hatched areas on sheet LS 1. See redlines. Topic: Lighting Plan Comment Number: 9 Comment Originated: 06/05/2013 Please remove "Custom Blending" from the title on sheet El. Comment Number: 10 _ Comment Originated: 06/05/2013 Please add a north arrow to sheet E1. Topic: Plat Comment Number: 11 Comment Originated: 06/05/2013 Please remove "Custom Blending" from the title and titles block on sheets 1 & 2, and the Statement of Ownership and Subdivision on sheet 1. Comment Number: 12 Comment Originated: 06/05/2013 The boundary and legal description close. Comment Number: 13 Comment Originated: 06/05/2013 Please add a Lienholders signature block as a placeholder. This may later be removed, if/when it turns out that there are no lienholders for this property. Comment Number: 14 Comment Originated: 06/05/2013 The title commitment note is acknowledged. The note will need to be changed when the commitment is received. Comment Number: 15 Comment Originated: 06/05/2013 Please provide current monument records for the public land corners shown for control. Per Development Review Submittal Requirement 3 (v) you do not need to tie to section control, if the boundary is entirely all or a portion of an existing subdivision. Topic: Site Plan Comment Number: 16 Comment Originated: 06/05/2013 Please remove "Custom Blending" from the title on sheet Al. Comment Number: 17 Comment Originated: 06/05/2013 There are lines over text issues on sheet Al. See redlines. Custom Blending PDP/FDP #FDP 13002 — Round 1 Comment Letter Page 2 June 7, 2013 .0 Department: PFA Contact: Jim Lynxwiler, 970-416-2869, ilyuxwilerna,aoudre-fire.orP- Topic: General Comment Number: 01 Comment Originated: 06/04/2013 The submitted HMIA is currently under review. All other fire department concerns have been resolved. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamar4uena,fceov.com Topic: General Comment Number: 1 Comment Originated: 06/07/2013 The development is required to meet the City's LID requirements which include 50% of the land area draining through an infiltration device and 25% of all private parking and drive aisles be porous pavement. The regulations also include an equal to or better option. If 50% of the existing site were to drain through and infiltration device, the City would agree that this option were equal to or better. Comment Number: 2 Comment Originated: 06/07/2013 A meeting should be planned to discuss the design parameters for these infiltration devices. Department: Technical Services Contact: Jeff County, 970-221-6588, icountvna.fcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 06/05/2013 Please remove "Custom Blending" from the title. Comment Number: 2 Comment Originated: 06/05/2013 There are lines over text issues on sheet A2. See redlines. Topic: Construction Drawings Comment Number: 3 Comment Originated: 06/05/2013 Please remove "Custom Blending" from the title and title block on all sheets. Comment Number: 4 Comment Originated: 06/05/2013 There are lines over text issues on sheet C-004. See redlines. Comment Number: 5 Comment Originated: 06/05/2013 Please rotate all text on sheet C-004 to read from the bottom and/or right of the plan sheet. See redlines. Topic: Landscape Plans Comment Number: 6 Comment Originated: 06/05/2013 Custom Blending PDP/FDP #FDP 13002 — Round 1 Comment Letter Page 2 June 7, 2013 1. appears that two parking spaces could be provided on the east side of the drive aisle that would still meet the 50 foot requirement). Comment Number: 4 Comment Originated: 06/05/2013 Pending confirmation at staff review, we may either need a new development agreement to apply to the property, or a note added on the plat stating that the development agreement for the original Custom Blending will apply to the replat property. Contact: Sheri Langenberger, 970-221-6573, slangenberger(aAmov.com Topic: General Comment Number: 1 Comment Originated: 06/05/2013 The project owes an additional $36 for the Final TDR Fee. Department: Light and Power Contact: Rob Irish, 970-224-6167, rirish(a)kgov.com Topic: General Comment Number: 1 Comment Originated:. 06/03/2013 The existing building is currently fed by a 300KVA 277/480v pad mount transformer at the NW corner of the building. Any relocation or modification to the existing electric facilities will be at the owner's expense. Comment Number: 2 Comment Originated: 06/03/2013 Electric Capacity Fee and Building Site charges will apply to any increase in KVA load above existing. Also, development charges will apply to Lot 3. Comment Number: 3 Comment Originated: 06/03/2013 A C-1 Form and a One -line Diagram will need to be submitted for any change in KVA load. Contact Light & Power Engineering @ 970-221-6700 to coordinate power needs and associated fees. Department: Outside Agencies Contact: Pete Wray, 970-221-6754, pwravna,fcEov.com Topic: General Comment Number: 1 Comment Originated: 06/05/2013 The FCLWD/SFCSD has reviewed the project and has no comments. Custom Blending PDP/FDP #FDP 13002 — Round 1 Comment Letter June 7, 2013 Page 2 0 for one group, identify different type per LCUASS Streetscape standards. Comment Number: 4 Comment Originated: 06/05/2013 For Landscape Plan, show limits of existing landscaping to delineate proposed landscaping. Comment Number: 5 Comment Originated: 06/05/2013 New building foundation: The 5' planting area facing street and east side should have landscape foundation planting in most areas vs. turf and cobble between footprint of building and sidewalk. Comment Number: 6 Comment Originated: 06/05/2013 New building street facing entrance, need to show connecting sidewalk to street sidewalk. Comment Number: 7 Comment Originated: 06/05/2013 Site Plan: Show existing sidewalk connection in front of new building from street to entrance area consistent with other plans. Comment Number: 8 Comment Originated: 06/05/2013 The Applicant owes $286.0 for initial submittal, plus $250.0 for PFA fee. Comment Number: 9 Comment Originated: 06/05/2013 Planting Plan: Include 5' landscape planting along east parking lot edge to screen minimum of 30" in height and along south drive isle. Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata(&kgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 06/05/2013 On the construction plans please look to fade back the existing utilities to make discernment between existing and proposed more recognizable. Topic: General Comment Number: 2 Comment Originated: 06/05/2013 Figure 19-6 of LCUASS specifies the minimum setback for a parking stall along a driveway from a public street. The range varies from 20 feet to 50 feet, but needs ADT information from a traffic study in order to determine. Depending on the information provided in the traffic study, there may need to be a couple of parking spaces removed on the west side of the drive aisle in order to meet this requirement (it Custom Blending PDP/FDP #FDP 13002 — Round 1 Comment Letter Page 2 June 7, 2013 k Fcityd ort Collins June 07, 2013 Cathy Mathis TB Group 444 Mountain Ave. Berthoud, CO Community Development & Neighborhood Services Planning 281 North College Avenue P.O. Box 580 Fort Collins, CO 80522.0580 970.221.6376 970.224.6111- fax RE: Harmony Technology Park Third Filing, Second Replat - Custom Blending #FDP 130021 Please see the following summary of comments from City staff and outside reviewing agencies for your Round Number 1 submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Pete Wray, at 970-221-6754, or pwr"(a)fcgov.com. Comment Summary Department: Current Planning Contact: Pete Wray, 970-221-6754, pwrayCa gov.com Topic: General Comment Number: 1 Comment Originated: 06/04/2013 The Combined PDP/FDP is scheduled for two rounds a review for the PDP and FDP. Staff will assess number of rounds required based on completeness of submittal and compliance of applicable standards. Comment Number: 2 Comment Originated: 06/05/2013 In reference to the Zoning comment for ROW landscaping, the parkway planting east of drive isle needs to include 4 street shade trees extending to east property line and in centerline of parkway strip between curb and detached sidewalk. The proposed Shumard Red Oak (located just east of drive isle - behind sidewalk) should be moved into parkway tree row and included as group of 4 trees mentioned above. Comment Number: 3 Comment Originated: 06/05/2013 Proposed street trees in front. of new building extension and in parkway (west of new drive isle) should be of another tree species than group of 4 street trees on east side of drive isle. If the Red Oak is used,