Loading...
HomeMy WebLinkAboutRIDGEVIEW CLASSICAL SCHOOL EXPANSION - SPAR - SPA130002 - CORRESPONDENCE -Comment: 2 05/17/2013: Will a fire lane be needed? If yes, please provide a utility plan for review and approval. Response: There will be no fire lane required.for this project. Current building is not sprinkled, and does plan to be sprinkled within the scope of the current project. Department: Zoning Contact: Peter Barnes, 970-416-2355, pbarnesna,fcaov.com Topic: General Comment Number: 1 05/17/2013: This is basically a project involving doing a plan over an old plan (National Child Care Center PUD). The applicant will need to submit a new site plan specific to their development (i.e. name of development, land use data, planning objectives, etc). Response: See attached site plan and elevations to reflect the new name of develeopement, etc. Comment Number: 2 05/17/2013: Will there be any site or landscape changes proposed? i.e. will the play area and play area fence remain? If there will be changes, they need to be reflected on the revised plans. Response: Current scope does not include removal of the fencing or modification of the play areas. Thank you, Michele fenwick - forrest Design - Job Captain THE NEENAN COMPANY 2607 Midpoint Drive I Fort Collins, CO 80525 P: 970.416.7279 1 C: 303.710.1857 1 michele.forrest@neenan.com Comment Number: 02 05/22/2013: FIRE CONTAINMENT The building exceeds 5000 square feet and shall be sprinkled or fire contained. If containment is used, the containment construction shall be reviewed and approved by the Poudre Fire Authority prior to installation. Response: The construction and building plan review is through the Colorado Division of Fire Prevention and Constrol. This is not a requirement in their review guidelines Permit has issued by Colorado Division of Fire Prevention and Control and Poudre Fire Authority. Comment Number: 03 05/22/2013: PREMISE IDENTIFICATION New and existing buildings shall be plainly identified. Address numbers shall be visible from the street fronting the property, plainly visible, and posted with minimum six-inch numerals on a contrasting background. 2006 International Fire Code 505.1 Response: Address Signage will be provided on the north side of the building. The letters will be six -inches in size and will contrast in color with the background to comply with code requirements. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford(a),keov.com Topic: General Comment Number: 1 05/22/2013: Please provide a simple drawing to show how traffic circulates in and out of the exisiting site and how it will circulate with the new site included. The submitted site plan does not represent the current site and therefore is inadequate to show how the new circulation will fit into the existing current site. Response: See revised site plan showing trafj'ic circulation, for the entire site. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffineton(affc¢ov.ora Topic: General Comment: 1 052/21/2013: The existing water service is i" service. Are there any plans to change this service. Response: There are no plans to change or alter this service. The I" service is adequate for any plumbing changes that will occure. archistructionm June 5, 2013 Ted Shepard City of Fort Collins Project Planner Community Development and Neighborhood Services 281 North College Avenue Fort Collins, CO 80522 Subject: Ridgeview Classical Schools Expansion, SPA 130002, Round Number 1 Dear Ted: Thank you for taking the time to review the drawings. This letter is in response to your review comments May 22, 2013. The package includes responses to your comments and revised drawings per your comments. Department: Light And Power Contact: Doug Martine, 970-224-6152, dmartine ep-pv.com Topic: General Comment Number: 1 05/13/2013: If any changes to electric system is necessary, please contact Light & Power Engineering at (970)221-6700. Response: There are no plans to change or alter this service. The existing service is adequate for any electrical changes that will occure. Department: PFA Contact: Jim Lynxwiler, 970416-2869, ilvnxwilerna aoudre-fwe.or¢ Topic: General Comment Number 01 05/22/2013: FIRE ALARM AND DETECTION SYSTEMS (Group E) A manual fire alarm system shall be installed in Group E occupancies. When automatic sprinkler systems or smoke detctors are installed, such systems or detectors shall be connected to the building fire alarm system. 2006 International Fire Code 907.2.3 Response: Fire Alarm and Detection System will be installed. Drawings will be .submitted to PFA as a deffered submittal for review. Integrated Project Delivery 2607 Midpoint Drive I Fort Collins, CO 80525 1 970-493-4787 1 Fax:970-493-5869 1 www.neenan.com