Loading...
HomeMy WebLinkAboutLITTLE BEAR'S CHILD CARE - FDP - FDP120012 - SUBMITTAL DOCUMENTS - ROUND 1 -RESPONS- Please see the revised silo plan Comment Number: 3 Comment Originated: 06/19/2012 06/192012: Please block out around the text on sheet 2. See redlines. RESPONSE: Ple.;se : vu i,,u rcvued tr.le piun. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/20/2012 06/20/2012: Signing and Marking notes should be revised to state "local entity traffic engineer" at each instance that they currently state "local entity engineer'. This is a permanent change to the signing and marking notes. Please revise your standard note file to reflect the change. RESPONSE' Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: General Comment Number: 2 Comment Originated: 06/202012 06/20/2012: If sign is moved, it is strongly suggested that the new location is coordinated with the locations of the existing water/sewer services and fire line so that the sign does not interfere with future maintenance of these services. RESPONSE. ,leayeu. li ki, sign neuves, it will gu ;hiough the sign permit process - Topic: Landscape Plans Comment Number: 1 Comment Originated: 06/192012 06/19/2012: If additional landscaping is planned along Riverside, show existing water/sewer services and fire line and provide the required separation distances. .,_ b;- jNSE: No additional landscaping is proposed along Rwersio�_ Department: Zoning Contact: Gary Lopez, 970-416-2338, glopez@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/15/201206/15/2012: Reminder that all signs and their locations are not approved by the PDP or theFDP. A separate sign permit is required for approval, this includes refacing of existing signs. RESPONSE: We have labeled the sign as an existing sign, the future location of which is to be determined through the separate sign permit process. Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 5 Comment Originated: 06/19/2012 0611912012: Please change the sheet number to 4 of 4. RESPONSE: Please see the revised elevation sheet. Topic: Construction Drawings Comment Number: 6 Comment Originated: 06/19/2012 06/19/2012: Please change the datum for the benchmark on sheets 1 & 2. The City of Fort Collins Vertical Control Network is on the 1929 Datum (unadjusted). RESPONSE. Revised. Comment Number: 7 Comment Originated: 06/19/2012 06/1912012: Please remove "Riverside II Condo Amended" from the sub -title. The Site Plan shows Lot 2, Viking I Subdivision being part of this project. Please add this to the sub -title. RESPONSE: [Revisedj Comment Number: 8 Comment Originated: 06/19/2012 06/192012: Please coned the lot designations on sheets 3 & 4. See redlines. RESPONSE. [Revised] Topic: Construction Drawings Comment Number: 9 Comment Originated: 06/19/2012 06/192012: There are line over text issues on sheet 3. RESPONSE: [Revised] Topic: General Comment Number: 10 Comment Originated: 06/19/2012 06/19/2012: The 2 legal descriptions for the right of way dedication state that the land is for easement purposes. Please change this to right of way. RESPONSE: We have changed this as requested. Topic: Landscape Plans Comment Number: 4 Comment Originated: 06/19/2012 06/19/2012: Please block out around the text on sheet 3. See redlines. RESPONSE: Piea&t: c-:e sndscape plan Topic: Site Plan Comment Number: 1 Comment Originated: 06/192012 06/19/2012: Please increase the size of the legal description text on sheet 1. See redlines. RESPONSE: Please see the revised site plan. Comment Number: 2 Comment Originated: 06/19/2012 06/192012: Please increase the text size on sheet 2. See redlines. Comment Number: 4 Comment Originated: 06/05/2012 O6/05/2012: There is an existing streetlight on Elizabeth St. as shown on the site plan. Street tree locations must be adjusted to provide 40 ft. clearance between the light pole and street trees (15 ft. if the tree is an ornamental type). RESPONSE: We have double cl ie�ked to ensure that these separation distances are adhered to. We have a canopy street tree just over 40 feet away, and an ornamental just over 15 feet away from the street light. Department: PFA Contact: Ron Gonzales, 970-416-2864, ronzales@poudre-fire.org Topic: General Comment Number: 1. Comment Originated: 06/19/2012 06/19/2012: Address numerals required to be visible from the street fronting the property. RESPONSE: Acknowledged. Comment Number: 2. Comment Originated: 06/19/2012 06/1912012: This is classified as an 1-4 institutional day care facility. It is required to be licensed by the State of Colorado. RESPONf - Acknowledged. Comment Number: 3. Comment Originated: 06119/2012 06/1912012: The existing fire sprinkler system shall be extended to cover any new areas in need of proper fire protection coverage. RESPONSE: Acknowledged. Comment Number: 4. Comment Originated: 06/19/2012 06/19/2012: Should grease -laden vapors be generated while heating meals, fire protection will be required under a Type 1 hood. RESPONSE. Acknowledged. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, waamarque@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/19/2012 O6/19/2012: Please use the City's hydrology computation method per our Stormwater Criteria Manual. This should actually reduce the quantity detention volume requirement. RESPONSE see revised drainage report Comment Number: 2 Comment Originated: 06/19/2012 06/19/2012: Discussions need to take place on what treatment method is best for water quality. P? SPONSF sec revised drainage reps Comment Number: 3 Comment Originated 06/19/2012 O6119/2012: Stormwater is ready for a public hearing. RESPONSE: Acknowledged. Department: Technical Services RESPONSE: Acknowledged. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tuchanan@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 06/2012012 06/20/2012 Label all existing trees as to type and size with intent to protect, transplant or remove. It appears all existing trees are can be retained. Meeting with City Forester on site can provide this information to the applicant to record on the plan. RESPONSE: We do intend to retain all existing trees, and therefore we are not triggering any transplant issues nor are we triggering any tree mitigation issues. We did meet with Tim Buchanan on the site and have included this information on the landscape plan. Comment Number: 2 Comment Originated: 06/20/2012 06/20/2012: Add tree protection notes in 3.2.1 G RESPONSE: We have now added this note. Please see the revised landscape plan. Comment Number: 3 Comment Originated: 06/20/2012 06120/2012: There are two existing maple trees on the west border of the parking lot. These two trees are not shown on the plan as existing. New trees are shown where these trees are located. RESPONSE: It was an inadvertent error that we left these trees off the drawings. We intend to retain these trees (as well as all other existing trees). Comment Number: 4 Comment Originated: 06/20/2012 06/2012012: Separation distances for trees are 10 between water and sewer mains and 6 feet for service lines. RESPONSE: Acknowledged. Department: Light And Power Contact: Doug Martine, 970-224-6152, dmartine@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/05/2012 06/05/2012: Records show that the existing building has 5 electric meters of 100 amps each (500 amps total capacity) at 120/240 volt single phase. If any changes to the existing electric service is necessary, please contact Light & Power Engineering at (970)221-6700. RESPONSE: Acknowledged Comment Number: 2 Comment Originated: 06/05/2012 06/05/2012: Electric development charges will apply for the lot at 1230 E. Elizabeth, even if no power is required to the site. RESPONSE: Acknowledged Comment Number: 3 Comment Originated: 06/05/2012 06/05/2012: Clearance of 8 ft. on the front (door) side, and 3 ft. on the other three sides of the transformer must be maintained. Also, the transformer must be accessible to utility personnel and equipment. The electric meter(s) must be accessible to utility personnel at all times without obtaining permission or an escort. RESPONSL the transformer is accessible from the Riverside Avenue outside of any fenced area 06/19/2012: Please confine with Water/Wastewater but engineering would request that existing and proposed (if applicable) water, sewer, and services be shown on the grading plan if a utility plan is not provided. RESPONSE: We did not receive this request from WM/W and are not able to find the location of the water and sewer services for this building. Topic: General Comment Number: 2 Comment Originated: 06/192012 06/192012: Thank you to the Owner, Applicant and Consultant's for addressing the conceptual review comments adequately. RESPONSE: You're welcome Comment Number: 4 Comment Originated: 06/192012 06/192012: As mentioned in Conceptual Review this project is responsible for dedicating right of way for East Elizabeth to meet the 76' wide right of way for collector with parking. The Viking I subdivision plat shows 60' was dedicated previously, however the right of way proposed to be dedicated by separate document is only 6' and the proposed dedication is shown as 7' on the site plan. Please provide additional information to support only dedicating 6' of additional right of way. If no other documents support a situation where this project is responsible for half the remaining right of way then 8' will need to be dedicated. RESPONSE: Please see the accompanying dedication documentation for 1 foot of additional ROW along Riverside, and an additional 8 feet along East Elizabeth. Comment Number: 5 Comment Originated: 06/192012 06/192012: It appears that fencing is proposed inside of the existing access and utility easement off of Elizabeth Street. The fence will need to be located outside of the easement. RESPONSE: We've submitted a formal application to vacate this easement on Friday July 20"i. Comment Number: 6 Comment Originated: 06202012 06202012: The sign along Riverside exists within the Right of Way. Please remove the note from the plans "existing sign to remain". Further discussions will need to occur with Zoning and an encroachment permit may be an option. RESPONSE: We have labeled this existing sign as an existing sign, the future location of which is to be determined through the separate sign permit process. Contact: Sheri Langenberger, 970-221-6573, slangenberger@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/14/2012 06/14/2012: The project owes an additional $215 for TDR fees. The acreage calculation on the application did not match that identified on the site plan. RESPONS- We submitted this fee as soon as we received this comment, so it has now been paid. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/082012 06/08/2012: No comments. LITTLE BEARS CHILD CARE COMBINED PDP/FINAL RESPONSE TO COMMENTS 7/25/2012 Department: Current Planning Contact: Courtney Levingston, 970-416-2283, clevingston@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/14/2012 06/14/2012: Is the Shed exisiting or proposed? If proposed, please provide detail on elevations. RESPONSE: The shed elevations are now shown on sheet 4 of 4 Comment Number: 2 Comment Originated: 06/14/2012 06/14/2012: Please call out the location of the transformer on landscape plans. All utilities must be screened. RESPONSE Please see the revised landscape plan, Comment Number: 3 Comment Originated: 06/142012 06/14/2012: Please call out where the main entrance will be located. RESPONSE: Please see the revised plans Comment Number: 4 Comment Originated: 07/052012 07/052012: For final, please include the owners information on the title page. RESPONSE. This information is now included on the title page. Topic: Site Plan Comment Number: 1 Comment Originated: 06/14201206/14/2012: For final, please provide bike rack, trash enclosure and automobile parking stalldetail to ensure each meets the LUC standards. RESPONSE. Please see the details loi ihese items now, included on the revised site plan Comment Number: 2 Comment Originated: 06/142012 06/142012: Plese call out the limits of development. I believe this is signified by the dashed line, correct? PESaDNSE. Please see the revised sde p';an which now flows the limits of development. Comment Number: 3 Comment Originated: 06/142012 06/142012: The Land Use Code only requires 1 handicapped parking space LUC3.2.2(K) RESPONSE . eQ� cuLJGed aic w:.uei -iovan ou two spdcca w uluw Oie i'iandicap parking spaces t0 be wide enough to meet standards. Department: Engineering Development Review Contact: Andrew Gingerich, 970-221-6603, agingerich@fcgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 06/19/2012