HomeMy WebLinkAboutEAST RIDGE - FDP - 33-98F - CORRESPONDENCE - VARIANCE REQUESTSteve Olt - RE: East Ridge Cover Variance Page 3
TST, Inc. Consulting Engineers
748 Whalers Way
Fort Collins, Co 80525
Phone: (970) 226-0557
Metro: (303)-595-9103
Fax: (970) 226-0204
rbanning(a)tstinc.com <mailto:rbanning antstinc.com>
www.tstinc.com <http://www.tstinc.com/>
This file(s) contains electronic horizontal and/or vertical design
information, which has been used by TST, Inc., in the formulation of
final development and/or construction documents. This electronic
information may be used exclusively by the party designated on the
attached transmittal letter for information purposes only. By receiving
this electronic information, the receiver agrees that this data may not
be transferred to any other party, that this electronic information may
not necessarily represent the information shown on the recorded or
approved final development and/or construction documents, and that the
receiver is responsible for verifying the information contained within
the electronic data against the recorded or approved documents.
CC: Sheri Langenberger; Steve Humann; Steve Olt; Yontahey@aol.com
Steve Olt - RE: East Ridge over Variance Page 2
requirements. You may put each of the instances in the same letter by devoting a paragraph to each
location. Please submit an exhibit that labels each location with a number or lettering system that
matches the locations in the letter. I'll need the associated sheets from the utility plans as well so that
Rick has everything he needs to review your request. I don't have a set to give him as they went back as
redlines with the last round otherwise you wouldn't have had to do that.
It would be great if you could get this to me by tomorrow so that Rick and Erika have time to review your
request prior to your next submittal. You don't have to however. You could resubmit the request with the
next round but you run the risk of redesign should they either not be approved OR they are approved with
conditions, such as a concrete street section for instance. A concrete section would require additional
design as I mentioned in a previous email and that would require additional review. I know you are trying
to wrap this up as quickly as possible so I highly recommend that you submit the variance as soon as
possible. I hope this helps, if not, let me know and I'll try explain it better.
Thank you,
Susan
>>> "Ryan Banning" <rbanning(ZDtstinc.com> 03/09/09 5:50 PM >>>
Susan,
I was able to increase the cover over the storm at the locations that
you had in question to 37" from 25" (st-1 B1 page 84) and 33" from 27"
(st-4B page 90) without more than negligible changes to the hydraulics
of the storm system or increasing the waterline depth beyond what is
reasonable and used in other locations throughout the site. Are you okay
with resolving the cover issue by increasing the cover as I have shown
instead of proceeding with a variance letter for these locations? It
appears that the only location other than these two that you took issue
with the depth of pipe was along the raw water system pipe at Sykes. In
that location we have 2.4' from top of pipe to finished grade and it
appeared that you were okay with flow fill for 5' of each side to
stabilize the pavement section.
Do you still need to see a variance letter for any of these locations or
others? I don't see any other problem spots as far as cover goes on our
p&p's.
Thanks,
Ryan Banning
Steve. Olt - RE: East Ridge Cover Variance Pagel
From: Susan Joy
To: Ryan Banning
Date: 3/10/2009 8:40:45 AM
Subject: RE: East Ridge Cover Variance
Hi Ryan,
Rick did not give me a formal letter of denial. We met in person to go over your original variance request
and he gave me his requirements verbally. Those in turn were placed in DMS and appeared in your
comment letter over a year ago.
Susan
>>> "Ryan Banning" <rbanning@tstinc.com> 3/10/2009 8:22 AM >>>
Susan,
Would you please send me a copy of Rick Richter's notice of denial for our original variance letter? I do
not recall seeing a copy of that and would like a copy for our files.
Thank you,
Ryan Banning
TST, Inc. Consulting Engineers
748 Whalers Way
Fort Collins, Co 80525
Phone: (970) 226-0557
Metro: (303)-595-9103
Fax: (970) 226-0204
rban ninq(a)tsti nc.com
www.tstinc.com
-----Original Message -----
From: Susan Joy rmailto:siov(a)fcgov.coml
Sent: Monday, March 09, 2009 10:25 PM
To: Ryan Banning
Cc: Sheri Langenberger; Steve Humann
Subject: Re: East Ridge Cover Variance
Hi Ryan,
You need to submit a variance request for each location that does not meet the minimum cover
requirements for any type of structure or pipe in the roadway. To date, none of the locations that do not
meet the minimum cover requirements have been approved including the last instance you mentioned
below. I am not the person who will either approve them or not so I can't waive the variance requests, I'm
sorry. The original variance request was reviewed last year by Rick Richter who was the Pavement
Manager at the time and he denied the variance pending a proper submittal. Please see the comment
letter for the complete history if you have any questions.
So yes, please submit a variance letter for each of the locations that do not meet the minimum cover